To install the control panel, do the following:
1. Mount the enclosure. A suitable location should include easy access for wiring, good lighting, suitable
access to power and earth ground, and ample space to work. The mounting surface should be flat and
dry. We do not recommend mounting metal enclosures directly onto concrete walls. Check with local
authorities to verify local codes regarding metal enclosure mounting.
Note:
To maintain compliance with UL 365, UL 690, and UL 1610, you must install the main control panel within a
safe, vault, or Extent #1 stockroom.
All Alliance system enclosures contain four mounting holes located in the corners of the enclosure.
Use appropriate mounting hardware to mount the enclosure to the mounting surface and the batteries
to the enclosure as shown in
Figure 1
.
For the AL-4017 (24 VAC) transformer, use the 1690 transformer kit. For the AL-4617 (18 VAC)
transformer, use the 1672 transformer kit.
Figure 1. Enclosure
Control panel board
Optional accessory boards
12 V battery
120 VAC
Chassis ground
Earth ground connection
mounting
Enclosure
screw
Transformer
Enclosure
screw
mounting
Enclosure
screw
mounting
PSTN
Tamper mounting holes
Содержание Alliance AL-4017
Страница 1: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual ...
Страница 6: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual vi ...
Страница 8: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual viii ...
Страница 10: ...Alliance AL 4017 AL 4617 Control Panel Installation Manual x ...