© 2017 UTC Fire & Security. All rights reserved.
4 / 4
2017-10-13
Assign a User Code
Press
(
0
)
+
Memory position from
01
to
99
Change
Master code
Press
(
0
)
+
Memory
position (
00
)
Set Output Timer
Pulsed Mode (01 to 99 sec):
Relay1:
Press (
1
) + (from
01
to
99
)
Relay2:
Press (
2
) + (from
01
to
99
)
OR
Latch Mode (ON/OFF):
Press (
1
) or (
2
) + (
00
)
Enter
NEW PIN Code
(1 to 8 digits)
Press “
A
” to validate
Validation OK?
1 small beep + 1 long beep + Yellow LED is ‘on’
Validate by pressing (
B
)
Multiple small beeps
+
Orange LED blinks rapidly
Yes
No
Enter “
Master Code
” OR “
000
” (if first time use)
Assign Output
Press
(
3
)
+
Memory position
from
(
01
to
99
)
+
Press (
1
) for Relay1
OR
Press (
2
) for Relay2
OR
Press (
12
) for
both outputs
Delete Single
Code
Press
(
9
)
+
Memory
position from
(
01
to
99
)
Delete ALL
codes
Press
(
8
)
+
(
99
)
Validation OK?
Press “
B
” (Orange LED is OFF)
Ex.: To assign User Code “6789” at Memory
Position “6” and Relay that activates for 5
seconds assuming Master Code = 000
000B + 0 + 06 + 6789 + A + 1 + 05 + A + B.
Yes
No
Programming flowchart
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Version
This document applies to
ACL875SU
hardware
Certification and Regulatory
information
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with
RoHS directive EN50581:2012
Contact information
https://firesecurityproducts.com
Product Warnings
and Disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY
PROFESSIONAL. UTC FIRE & SECURITY CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON
OR ENTITY BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY
TRAINED OR EXPERIENCED TO CORRECTLY INSTALL SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information, please check
https://www.utcfssecurityproducts.eu/productwarning/ or scan the following code: