Interlogix 60-660-43 Скачать руководство пользователя страница 7

 

P/N 466-1452 

• REV E • ISS 16OCT18 

 

7 / 10 

4.  Slide the DIP switch down to put the receiver in run 

mode. 

To delete a keychain touchpad from the receiver, repeat the 
procedure for each button on a keychain touchpad button 
that is learned into a zone. A keychain touchpad is deleted 
only when all learned buttons are deleted from their 
respective zones. 

Zone/trouble outputs N/O or N/C 

All eight zones and both trouble outputs default to N/C, and 
can be changed to N/O. 

To program a zone output N/O or N/C, do the following: 

1.  To enter program mode, slide the DIP switch up. 

2.  Press the tamper switch once to gain access to 

configuring zone outputs. The low battery LED should 
turn on or flash. 

3.  Press and release the ADV switch until the desired zone 

LED turns on. 

4.  Press and release the SEL switch to change the output 

configuration to the desired setting. (zone LED on = N/C, 
zone LED off = N/O). 

5.  Repeat the procedure for each zone configuration 

change. 

6.  Slide the DIP switch down to return to run mode. 

To program both trouble outputs N/O or N/C, do the 
following: 

1.  To enter program mode, slide the DIP switch up. 

2.  Press the tamper switch once to gain access to 

configuring zone outputs. 

3.  Press and release the ADV switch until all zone LEDs 

are off (nine presses) to select the trouble outputs. 

4.  Press and release the SEL switch to change the trouble 

outputs configuration to the desired setting (low battery 
LED on = N/C, low battery LED flashing = N/O). 

5.  Slide the DIP switch down to return to run mode. 

RF supervision 

All eight zones default to RF supervised, and can be 
changed to be unsupervised. 

To enable or disable RF supervision on a zone, do the 
following: 

1.  To enter program mode, slide the DIP switch up. 

2.  Press the tamper switch twice to gain access to 

configuring zone supervision. 

3.  Press and release the ADV switch until the desired zone 

LED turns on. 

4.  Press and release the SEL switch to change the RF 

supervision configuration to the desired setting.  

5.  Repeat the procedure for each zone configuration 

change. 

6.  Slide the DIP switch down to return to run mode. 

Note: 

Keychain touchpads are not supervised. Panic button 

transmitters learned into zone 1 are not supervised. 

Keychain touchpad zone output 
responses 

Zone outputs 3 through 6 can be set up to respond by 
switching momentarily or to maintain (toggle on/off for each 
activation). 

To change the zone output response to momentarily or 
maintain, do the following: 

1.  To enter program mode, slide the DIP switch up. 

2.  Press the tamper switch twice to gain access to 

configuring zone outputs.  

3.  Press and release the ADV switch until the desired zone 

LED (3 to 6) turns on. 

4.  Press and release the SEL switch to change the zone 

output response to the desired setting. The LED for the 
selected zone should turn off (maintained) or on 
(momentarily), indicating the current configuration. 

5.  Advance to another programmable option or slide the 

DIP switch down to return to run mode. 

Connecting the receiver to a 
control panel 

There are four ways to wire the loop receiver to the control 
panel. 

Figure 9: Supervised N/O loop wiring diagram  shows a 
wiring diagram for a supervised N/O loop. 

Figure 9: Supervised N/O loop wiring diagram  

 

Note: 

You can connect multiple normally open (N/O) loop 

receiver zone outputs in parallel to panel zone inputs. 

Figure 10: N/C loop wiring diagram shows a wiring diagram 
for an N/C loop. 

Panel terminals 

Zone 1

Return

Panel GND

Panel +12V

EOL resistor

Receiver terminals

Panel terminals

Содержание 60-660-43

Страница 1: ...2 MHz panic button transmitters two and four button keychain touchpads with the exception of smoke detectors Control panel compatibility The receiver is compatible with control panels designed with hardwire loops where the loop negative is ground common loop ground The receiver is not directly compatible with powered loops two wire smoke detector loops and glassbreak detector loops If the loop on ...

Страница 2: ...nsistors for the zone and trouble outputs see Figure 2 The outputs can be open high impedance or closed shorted to ground which can be configured to be normally closed N C or normally open N O Each output can be wired to the control panel Zone outputs There are eight zone outputs labeled 1 through 8 When a learned transmitter is activated the corresponding zone output switches to the alarm state a...

Страница 3: ...Receiver failed power up test Blinks off momentarily Receiver received an RF signal whether learned or not Run mode LED indications In run mode the LEDs indicate three conditions alarm low battery and supervisory failure Alarm status conditions When the trouble LEDs are both off the zone LEDs indicate alarm information The zone LEDs turn on for zones that are open in alarm Zone LEDs remain off for...

Страница 4: ... receiver do the following 1 To remove the receiver cover press down on the top center of the cover see Figure 6 and pull the cover away from the base Figure 6 Remove the cover Caution You must be free of static electricity before handling circuit boards Touch a bare metal surface or wear a grounding strap before handling circuit boards 2 Press the lower right corner of the base until the lower ri...

Страница 5: ... When learned into zone 2 both of these key presses work together to provide a maintained toggle output response only one of these buttons needs to be learned for both to work Typically this output would be used for a maintained keyswitch on the control panel for arming disarming refer to your control panel documentation for this application Zone 3 lights You can only learn this keypress into zone...

Страница 6: ...de the DIP switch up The low battery and supervisory LEDs blink back and forth 2 Press and release the ADV switch until the desired zone LED turn on If you press and hold the ADV switch you will advance to the next zone and cause the zone LED to flicker 3 Press and release the SEL switch once to select this zone for learning transmitters The zone LED remains on and the low battery and supervisory ...

Страница 7: ...sion on a zone do the following 1 To enter program mode slide the DIP switch up 2 Press the tamper switch twice to gain access to configuring zone supervision 3 Press and release the ADV switch until the desired zone LED turns on 4 Press and release the SEL switch to change the RF supervision configuration to the desired setting 5 Repeat the procedure for each zone configuration change 6 Slide the...

Страница 8: ... responses Transmitter Should cause Sensors 7 to 8 beeps and LED flashes Keypad touchpads 1 button press 2 beeps and LED flashes 2 button press 8 beeps and LED flashes To test the system using a piezo beeper do the following 1 Connect a piezo beeper between the test output T and ground GND as shown in Figure 13 Piezo status beeper connections Figure 13 Piezo status beeper connections 2 Make sure t...

Страница 9: ...nformation on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the QR code Certification TUV 0123 Test report reference CEQP 60 660 43 Applied standards EN50130 4 1995 A2 2003 Safety Test report reference CEQP 60 660 43 Applied standards EN 60950 1 2001 Radio TUV 0123 Test report reference CEQP 60 660 43 Applied standard...

Страница 10: ...10 10 P N 466 1452 REV E ISS 16OCT18 ...

Отзывы: