Interlogix 60-660-43 Скачать руководство пользователя страница 8

 

8 / 10 

 

P/N 466-1452 

• REV E • ISS 16OCT18 

Figure 10: N/C loop wiring diagram 

 

Figure 11:  Nonsupervised loop wiring diagram shows a 
wiring diagram for a nonsupervised loop. 

Figure 11:  Nonsupervised loop wiring diagram 

 

Figure 12: Relay wiring diagram shows a wiring diagram 
when using a relay. 

Note: 

The 12 VDC relay coil resistance must be at least 

300 ohms. 

Figure 12: Relay wiring diagram 

 

RF reception test 

You can test the receiver by either counting the LED flashes 
when transmitters are tripped, or by counting the beeps 
emitted by an attached piezo beeper (optional). 

To test the system using the receiver LED, do the following: 

1.  Make sure the DIP switch is down (normal operation/run 

mode). 

2.  Trip all sensors in the system. After each trip, watch for 

the correct number of LED flashes as indicated in 
Table 3. 

Table 3: LED/piezo test responses 

Transmitter 

Should cause 

Sensors 

7 to 8 beeps and LED flashes 

Keypad 
touchpads 

1-button press 

2 beeps and LED flashes 

2-button press 

8 beeps and LED flashes 

To test the system using a piezo beeper, do the following: 

1.  Connect a piezo beeper between the test output (T) and 

ground (GND) as shown in Figure 13: Piezo status 
beeper connections.
 

Figure 13: Piezo status beeper connections 

2.  Make sure the DIP switch is down (normal operation/run 

mode). 

3.  Trip all sensors in the system. After each trip, listen for 

the correct number of beeps from the piezo beeper as 
indicated in Table 3. 

Securing the cover 

To help prevent accidental tamper alarms caused by cover 
removal, install the two self-tapping screws (included) on top 
of the cover (Figure 14:  Cover screws). 

Receiver terminals 

Zone 1

Return

Panel GND

Panel +12V

Receiver terminals

Panel terminals

Zone 1

Return

Panel GND

Panel +12V

EOL resistor

Receiver terminals

Panel terminals

Zone 1

Return

Panel GND

Panel +12V

N/O

COM

N/C

Coil

Coil

Receiver terminals

Panel terminals

Содержание 60-660-43

Страница 1: ...2 MHz panic button transmitters two and four button keychain touchpads with the exception of smoke detectors Control panel compatibility The receiver is compatible with control panels designed with hardwire loops where the loop negative is ground common loop ground The receiver is not directly compatible with powered loops two wire smoke detector loops and glassbreak detector loops If the loop on ...

Страница 2: ...nsistors for the zone and trouble outputs see Figure 2 The outputs can be open high impedance or closed shorted to ground which can be configured to be normally closed N C or normally open N O Each output can be wired to the control panel Zone outputs There are eight zone outputs labeled 1 through 8 When a learned transmitter is activated the corresponding zone output switches to the alarm state a...

Страница 3: ...Receiver failed power up test Blinks off momentarily Receiver received an RF signal whether learned or not Run mode LED indications In run mode the LEDs indicate three conditions alarm low battery and supervisory failure Alarm status conditions When the trouble LEDs are both off the zone LEDs indicate alarm information The zone LEDs turn on for zones that are open in alarm Zone LEDs remain off for...

Страница 4: ... receiver do the following 1 To remove the receiver cover press down on the top center of the cover see Figure 6 and pull the cover away from the base Figure 6 Remove the cover Caution You must be free of static electricity before handling circuit boards Touch a bare metal surface or wear a grounding strap before handling circuit boards 2 Press the lower right corner of the base until the lower ri...

Страница 5: ... When learned into zone 2 both of these key presses work together to provide a maintained toggle output response only one of these buttons needs to be learned for both to work Typically this output would be used for a maintained keyswitch on the control panel for arming disarming refer to your control panel documentation for this application Zone 3 lights You can only learn this keypress into zone...

Страница 6: ...de the DIP switch up The low battery and supervisory LEDs blink back and forth 2 Press and release the ADV switch until the desired zone LED turn on If you press and hold the ADV switch you will advance to the next zone and cause the zone LED to flicker 3 Press and release the SEL switch once to select this zone for learning transmitters The zone LED remains on and the low battery and supervisory ...

Страница 7: ...sion on a zone do the following 1 To enter program mode slide the DIP switch up 2 Press the tamper switch twice to gain access to configuring zone supervision 3 Press and release the ADV switch until the desired zone LED turns on 4 Press and release the SEL switch to change the RF supervision configuration to the desired setting 5 Repeat the procedure for each zone configuration change 6 Slide the...

Страница 8: ... responses Transmitter Should cause Sensors 7 to 8 beeps and LED flashes Keypad touchpads 1 button press 2 beeps and LED flashes 2 button press 8 beeps and LED flashes To test the system using a piezo beeper do the following 1 Connect a piezo beeper between the test output T and ground GND as shown in Figure 13 Piezo status beeper connections Figure 13 Piezo status beeper connections 2 Make sure t...

Страница 9: ...nformation on warranty disclaimers and product safety information please check https firesecurityproducts com policy product warning or scan the QR code Certification TUV 0123 Test report reference CEQP 60 660 43 Applied standards EN50130 4 1995 A2 2003 Safety Test report reference CEQP 60 660 43 Applied standards EN 60950 1 2001 Radio TUV 0123 Test report reference CEQP 60 660 43 Applied standard...

Страница 10: ...10 10 P N 466 1452 REV E ISS 16OCT18 ...

Отзывы: