background image

 

Operation: 

 
 
Connect a suitable AC mains power source to the rear IEC connector. Connect a RS-232 
signal or a RS-422 signal to the DB-9 RS-422 input connector and select the desired 
mode with the toggle switch. Turn on the AC power switch on the rear panel. 
 
 
 

Rear Panel Connections: 
 
 

Inputs (RS-422 or RS-232):  

DB-9 Female. Toggle switch mode selected. 

 
RS-422 Pin 4=D+, Pin 8=D-, Pin 5= Gnd.  
RS-232  Pin 3=R, Pin 5=Gnd. 
 

Outputs RS-422: 

(15) 

TWINAX connectors. Center pin= D+  

 

Status Port RS-422 or RS-232: 

DB-9 Female. Toggle switch mode selected 

RS-422 Pin 4=D+R, Pin 8=D-R, Pin 5= Gnd. ; Pin 7=D+T, Pin 9=D-T 
RS-232  Pin 2=T, Pin 3=R, Pin 5=Gnd. 
 
 

AC INPUT

:   

AC mains voltage is applied through the IEC connector.  

 

 

 

90– 265 VAC  47-470 Hz.

  

 

 
 

Power Supply: 

 
The distribution amplifier uses a “Universal Input” switching power supply for cool and 
reliable operation. The power supply accepts any common voltage between 90 and 265 
VAC or 100 to 370 Volts DC without any adjustment. A separate line filter is built into 
the DA-422-15T for an additional measure of EMI suppression. The Power supply used 
is UL listed and approved by several other agencies. 
 
 
 
 
 
 
 
 
 

Отзывы: