 Coil Nailer

Drives Wire Collated Nails (1-1/4" to 2-1/4" / 32 to 57mm)

Model No. CN55-15

Item No. 65530

8

Interchange Brands  

Operator’s Manual

22 . 

KEEP ALL SCREWS AND COVERS MOUNTED TIGHTLY IN PLACE. 

Keep all screws and covers tightly mounted . Check their condition periodically . 

Never use the nailer if parts are missing or damaged .

23 . 

DO NOT USE THE WRONG FITTING ON NAILER. 

The nailer and air hose must have a hose coupler so that all pressure is removed 

from the nailer when the coupler is disconnected . The connector on the nailer 

must not hold pressure when the air supply is disconnected . If the wrong fitting is 

used, the nailer can remain charged with air after disconnecting and thus will be 

able to drive a nail even after the air line is disconnected, possibly causing injury .

24 . 

DO NOT LOAD FASTENERS WITH TRIGGER PULLED OR SAFETY/PUSH 

LEVER DEPRESSED. 

When loading fasteners into the nailer or when connecting the air hose:

 

„

Do not pull the trigger

 

„

Do not depress the safety/push lever

 

„

Keep the nailer pointed downward

25 . 

CHECK FOR LIVE WIRES. 

Avoid the risk of severe electrical shock by checking for live electrical wires that 

may be hidden by walls, floors or ceilings . Turn off the breaker switch to ensure 

there are no live wires .

26 . 

HOSES. 

Air hoses should be professional grade and have a minimum of 150 psi working 

pressure . Make sure that the hose is securely fastened . If there is any damage to 

the hose, replace it before using the nailer .

27 . 

PLACE NAILER PROPERLY ON WORK PIECE. 

Do not drive fasteners on top of other fasteners or with the nailer at too steep of 

an angle . The fasteners can ricochet and hurt someone .

28 . 

BE CAREFUL OF DOUBLE FIRING DUE TO RECOIL. 

If the safety/push lever is unintentionally allowed to re-contact the work piece 

following recoil, an unwanted fastener will be driven . 

In order to avoid this undesirable double fire: 

 

„

Intermittent operation ﹙trigger or single firing﹚  

(not available on all models)

 

1﹚ Set the switching device to SINGLE ACTUATION MECHANISM . 

2﹚ Pull the trigger rapidly and firmly .

 

„

Continuous operation ﹙safety/push lever firing﹚ 

1﹚ Do not press the nailer against the wood with excessive force . 

2﹚ Separate the nailer from the wood as it recoils after fastening .

29 . 

DO NOT DRIVE FASTENERS CLOSE TO THE EDGE OR CORNER OF THE 

WORK ESPECIALLY WHEN USING THIN MATERIAL. 

The work piece is likely to split and the fastener could fly free and hit someone .

30 . 

NEVER DRIVE FASTENERS FROM BOTH SIDES OF A WALL AT THE SAME 

TIME.  

The fasteners could be driven into and through the wall and hit a person on the 

opposite side .

31 . 

DO NOT DISCONNECT AIR HOSE FROM NAILER WHILE FINGER IS ON 

THE TRIGGER. 

The nailer can fire when it is re-connected to an air supply .

Содержание 65530

Страница 1: ...tool Carefully read through this OPERATOR S MANUAL to ensure efficient safe operation It is recommended that the MANUAL be kept readily available as an important refer ence when using this tool 15o Co...

Страница 2: ...s 4 Parts Identification 5 Accessories 5 Safety Information Safety Instructions 6 9 Employer s Responsibilities 9 Operating the Nailer Air Supply Connections Operating Pressure 10 11 Lubrication 11 Op...

Страница 3: ...could result in DEATH or SERIOUS INJURY Most accidents that result from the operation and maintenance of nailers are caused by the failure to observe basic safety rules or precautions An accident can...

Страница 4: ...s Drums Export Wooden Boxes and Wooden Fencing General Construction Applications Including Siding Decking Crating and Sheathing Nail Specifications WARNING Be sure to use only the genuine nails recomm...

Страница 5: ...p Exhaust Cover TOOL AIR FITTINGS This tool uses a minimum 1 4 N P T male plug The inside diameter should be 0 28 7mm or larger The fitting must be capable of discharging tool air pressure when discon...

Страница 6: ...ears from loud noise Wear head protection to protect your head from flying objects 3 KEEP FACE HANDS AND FEET AWAY FROM FIRING HEAD AT ALL TIMES Never place your face hands or feet near the firing hea...

Страница 7: ...ice center 16 BEFORE STARTING WORK CHECK THE FASTENING OPERATION SWITCHING DEVICE Not available on all tool models If this nailer includes a fastening operation switching device check the setting of t...

Страница 8: ...SES Air hoses should be professional grade and have a minimum of 150 psi working pressure Make sure that the hose is securely fastened If there is any damage to the hose replace it before using the na...

Страница 9: ...D PARTS ACCESSORIES OR FASTENERS Unauthorized parts accessories or fasteners may void your warranty and can lead to tool malfunction and resulting injuries Only authorized service personnel should rep...

Страница 10: ...ssors for Process Industries Moisture or oil in the air compressor may accelerate wear and corrosion in the nailer Drain daily Connections 1 Fittings Install a female coupler to the hose The female co...

Страница 11: ...erating pressure is 150 psi Select the operating pressure within this range for the best fastener performance The nail length and thickness and the hardness of the wood are factors in determining what...

Страница 12: ...work piece and pull the trigger The tool must not operate 9 Disconnect the air supply OPERATION Danger to the eyes exists due to the possibility of flying fasteners and debris when operating the naile...

Страница 13: ...ings To change setting pull up on the post and twist to the correct step The nail support should be adjusted correctly to the position indicated in inches and millimeters inside magazine 3 Nail loadin...

Страница 14: ...he work piece The tool must fire the fastener 4 Adjust the air pressure to the lowest setting possible according to the diameters and length of fastener and the hardness of work piece WARNING Always f...

Страница 15: ...f lubrication Apply air tool lubricant Nails jam in tool Bent nails Replace with new nails Broken or chipped driver Replace piston driver assembly bumper Wrong size nail Replace with correct type of n...

Страница 16: ...E 2 Remove all nails 3 Remove the jammed nail with a slotted head screwdriver 4 In case of frequent jams contact an authorized service center A qualified person should perform repairs and maintenance...

Страница 17: ...ler Drives Wire Collated Nails 1 1 4 to 2 1 4 32 to 57mm Model No CN55 15 Item No 65530 17 Interchange Brands Operator s Manual Parts DRAWING SCHEMATICS FOR CN55 15 Parts Drawing Schematics Parts List...

Страница 18: ...510210 O RING 6 3X1 8 22 310300 CYLINDER 73 510180 O RING 5 8X1 9 23 520130 CYLINDER SEAL 74 640250 STRAIGHT PIN B3X15 24 510680 O RING 50X2 65 75 420090 TRIGGER VALVE CAGE 25 110320 BODY 76 510410 O...

Страница 19: ...5K8 Kit 8 Feeder Kit for CN55 15 98488 CN55K9 Kit 9 Bumper Kit for CN55 15 WARNING Always follow the tool manufacturer s safety and maintenance instructions Always wear safety glasses with side shield...

Страница 20: ...roduction industrial applications are excluded from this warranty 4 Labor charges maintenance or loss damage and repairs resulting from improper operation are not covered by this warranty GENERAL WARR...

Отзывы: