Inter-m NLM-8000C Скачать руководство пользователя страница 2

NLM-8000C

Local Machine

- ID Set

1) Device ID can be set.

2) In case ID is changed, if the selection switch is

pressed for 5 seconds or longer and the display

window ID phrase is changed into ID SET phrase

and ID can be changed.

3) When selection switch is pressed at the state ID value

to  change  is  displayed  after  turning  the  selection

switch, Select, Cancel phrases are displayed. If Select

is selected, ID is changed and is cancelled if Cancel

is selected.

- Termination

1) You can check the device termination status.

2) This menu can check ON/OFF status of termination

resistance  switch  only,  and  the  change  can  be

done only with the termination switch at the back

of the device.

3) If you press the selection switch, it returns to Set-

ting screen.

- Firmware

1) You can check the firmware version of the device.

- LeD Control 

Device setup method and cautions

1. Device Basic Operation

- Waiting Screen

1)If you connect NPX-8000 and NLM-8000C, power

is  supplied  to  NLM-8000C,  and  NLM-8000C  is

ON.

2)In case ID of NLM-8000C collides, ID set window

is displayed. In this case, ID is reset.

※ Refer to 2. Device set explanation or MP-8000

manual for ID set.

3)In case NLM-8000C was connected with the de-

vice  normally,  in  case  it  is  not  communicated,

LINK ERROR is displayed. In this case, check

communication status (cable, etc.) again.

4)When there is no input for 10 seconds on the wait-

ing display, it is converted into sleep mode.

2. Device Set

It is a menu that can set the device.

1)When the selection switch is pressed for 10 sec-

onds or longer on volume mode screen or channel

mode screen, it moves to the setting screen.

2)The menu pops up that can set if the switch is

turned. After turning the selected switch and mov-

ing  to  the  menu  desired,  selection  switch  is

pressed and the menu is selected.

3)6. When Back is selected, it returns to Volume

Mode.

ID

1

ID Set

Cancel

Select

ID Set

1

Termination

OFF

Firmware

Ver0.0.0.0

Led Control

OFF

ON

LINK ERROR!

Setting

1. ID

2. Termination

3. Firmware

4. Led Control

5. Factory Reset

6. Back

Содержание NLM-8000C

Страница 1: ...elect 3 Led Status Displaying Led It is LED that displays the operation status of the device Channel mode GREEN LED is on Volume mode BLUE LED is on Sleep mode When Led Control is ON BLUE LED is on When Led Control is OFF LED is off In case Led Control is OFF LED turns off Communication error RED LED is on Setup mode MAGENTA LED is on Others RED LED is on at Mute status 1 Termination Switch It is ...

Страница 2: ...nnect NPX 8000 and NLM 8000C power is supplied to NLM 8000C and NLM 8000C is ON 2 In case ID of NLM 8000C collides ID set window is displayed In this case ID is reset Refer to 2 Device set explanation or MP 8000 manual for ID set 3 In case NLM 8000C was connected with the de vice normally in case it is not communicated LINK ERROR is displayed In this case check communication status cable etc again...

Страница 3: ... the present Volume is increased and it can change up to 100 at largest 4 If the selection switch is pressed the present Volume is Muted When it is Muted Mute phrase is displayed at the center of the screen and when controlling the Volume Mute phrase is displayed at the left bottom 5 If the selection switch is pressed again Mute is cancelled On the Channel or Setting screen Mute cannot be set with...

Страница 4: ...thout pre notice No 140523 2017 5 RJ 45 RJ 45 Push Encoder STATUS LED DC DC CAN DRIVER MCU OLED DISPLAY 1 3 inch Block Diagram application 120 240V 50 60Hz 30W AC INPUT DC 24V RS 232C MONITOR OUT 8 7 6 5 4 3 2 1 G G RX TX CONTACT OUTPUT 8 7 6 5 4 3 2 1 CONTACT INPUT POWER ON OFF MUTE EXT B A CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 AUDIO OUTPUT G G G G G G G G AUDIO INPUT CH8 CH7 CH6 CH5 CH4 CH3 CH2 CH1 G ...