7.9 Different engraving depth or could not engrave deep depth.
1.
Check whether the water circulation system is smoothly flowing (water pipes bent or broken); 2.
Check whether the focal length is normal, if the focal length is wrong, please adjust the focus.
3.
Check whether the laser path is right, if so, please adjust the laser path again.
4.
Check whether the mirrors or lens are dirty, if so, please clean them.
5.
Check whether the lenses are broken, if so, please change new one.
6.
Check whether the outside of the laser tube is dirty, if so, please clean it.
7.
Check whether the worktable is plain.
8.
Check whether the X-axis cross girder is parallel.
9.
Check whether the temperature is higher than 30
℃
(change the water for cycling)
10
Check whether the laser head or Focus Len is loose (fasten them)
11.
Check whether the laser tube is aging (change it; free changing within guarantee time)
7.10 Wrong engraving and not following the file engraving
1.
Initialization is not correct, the data was sent out (please make a change)
2.
Operation was not in order(need to key in again)
3.
Control card problem
4.
The configuration number of the software was problem
5.
The driver fault or current subdivision numbers setting was different with the software.
6.
Inverter interference or wire problem.
7.
Electrostatic interference
WWW.INTERLASER.RU