I N S T A L L A T I O N M A N U A L
E D G E ™ D I V I N G S Y S T E M
6
EDGE-IM Rev. 6/08 (BBK-EDGE INSTAL)
TABLE 3 – PLACEMENT CHART
ADDITIONALLY REFER TO:
ANSI/NSPI-5 2003 American National Standard for Residential Inground Swimming
Pools and to page 5 for Inter-Fab Residential Inground Pool Minimum Specifications.
NOTE: WHEN COPING IS USED, DO NOT SET FRONT JIG BOLTS CLOSER THAN 3” FROM THE
BACK EDGE OF THE COPING.
* IMPORTANT:
The distance for setting the front jig bolt (S) from the water’s edge is valid only if the minimum water depth is maintained
at the tip of the board noted as point “A” in ANSI/NSPI-5 2003 American National Standard for Residential Inground Swimming Pools.
If minimum water depth is not maintained the distance (S) must be adjusted accordingly.
**
“WA” dimension is valid only in conjunction with the minimum depth at point “A” for type pool in accordance with ANSI/NSPI-5
2003 American National Standard for Residential Inground Swimming Pools.
NOTE: READ THESE INSTRUCTIONS IN THEIR ENTIRETY BEFORE
ATTEMPTING THE INSTALLATION.
IMPORTANT:
THESE DIMENSIONS
ARE ACCURATE ONLY
FOR VERTICAL POOL
WALLS,
TYPICALLY
GUNITE CONSTRUC-
TION
, WITH LESS
THAN A 3’ RADIUS TO
THE POOL FLOOR.
DUE TO THE VARYING
SIZES OF OTHER
POOLS,
TYPICALLY
VINYL LINER CON-
STRUCTION
, PLEASE
CONTACT CUSTOMER
SERVICE FOR PROPER
JIG PLACEMENT.
1-800-737-5386
EDGE
DIVING
SYSTEM
PART #
NOMINAL
BOARD
LENGTH
ANSI/
NSPI-5
POOL
TYPE
DISTANCE FROM
WATER’S EDGE TO
FORWARD JIG BOLT
(S)
DISTANCE FROM
END OF BOARD TO
FORWARD JIG BOLT
MAX HEIGHT
OF BOARD
ABOVE
WATER
(HOW)
EDGE-BASE
6’
I 31.5”
49.5”
18”
20”
EDGE-BASE
6’
II
31.5”
49.5”
18”
20”
EDGE-BASE
6’
III
25.5”
49.5”
24”
26”
EDGE-BASE
6’
IV
19.5”
49.5”
30”
30”
EDGE-BASE
6’
V
13.5”
49.5”
36”
40”
EDGE-BASE
8’
I
EDGE-BASE
8’
II
EDGE-BASE
8’
III
44.25”
68.25”
24”
26”
EDGE-BASE
8’
IV
38.25”
68.25”
30”
30”
EDGE-BASE
8’
V
32.25”
68.25”
36”
40”
MIN.
OVERHANG
PLUS OR
MINUS 3”
(WA)
Cannot put 8' jump board on type I pool
Cannot put 8' jump board on type II pool
FIG. A – EDGE FIBERGLASS BASE PLACEMENT SPECIFICATIONS:
INTER-FAB CANNOT GUARANTEE CUSTOMER’S CONCRETE OR THICKNESS