32
IntelliTouch Personality Kit Installation Guide
System Start-Up
The following information describes basic start-up procedures. For more detailed troubleshooting
information, refer to the
IntelliTouch Systems User’s Guide (P/N 520102). Before you power up the
Power/Load Center check the following:
Check Electronics
Check that the following plugs are seated correctly on the Personality board:
•
Relay connectors -
FLTR PUMP
-
AUX1 - AUX10
•
Temperature sensors connectors
WATER, SOLAR, AIR
•
Transformer wire harness
J2
attached to the Personality board.
•
Heater control connector
ELEC HTR
or two-wire screw terminal.
Refer to Summary Installation Steps (page 8) and Power/Load System Wiring Diagrams, page 25
and 26.
Testing the auxiliary relays
Affix the auxiliary relay labels to the appropriate buttons on the Outdoor Control Panel. If necessary,
write the function on the control panel.
•
Toggle the filter pump, each auxiliary circuit, heater and solar and verify the function. Press
the SYSTEM CONTROL button to set the system in
“AUTO”
mode when done.
System Test
The following describes how to test the Outdoor Control Panel to activate the heater, valves and
pumps. This test assumes that all system equipment has been properly installed and connected to
the Power/Load Center.
Testing Valve Actuators and Pumps
Use the following steps to test the valve actuators (CVA24T) for proper rotation. For Outdoor Control
Panel System i5, i7+3, i9+3 (shared equipment).
To test the valve actuators and pump:
1. Power up the Power/Load Center.
2. Press the
SYSTEM CONTROL
button on the Outdoor Control Panel until the
SERVICE
light
is on. .
3. Press the
V (Valve)
button to select
POOL.
4. Press the
F
(Filter Pump)
button to activate the filter pump. Water will be removed from the
pool and returned to the pool.
5. Set both valve actuators (CVA-24T) for suction and return. Use the toggle switch on the rear
of the CVA-24 to withdraw and return water from the pool.
Note:
With the filter pump operating, if the water is not being removed and returned to the
pool, it may be necessary to reverse the
RETURN
with
VLV A
(or
VLV B
) plugs on the
Personality board.
Содержание Pool and Spa Control System
Страница 40: ...34 IntelliTouch Personality Kit Installation Guide System Wiring Diagram Power Center...
Страница 41: ...35 IntelliTouch Personality Kit Installation Guide System Wiring Diagram Load Center...
Страница 43: ...37 IntelliTouch Personality Kit Installation Guide Notes...
Страница 44: ...38 IntelliTouch Personality Kit Installation Guide Notes...
Страница 45: ......
Страница 46: ...P N 520101 Rev D 520101...