10

IntelliTouch Personality Kit Installation Guide

Plumbing Requirements

It is important that the pool and spa plumbing system be in accordance with local codes and the
Recommended Hydraulic Schematics (page 11, 12 and 13).  Before starting, please review the
diagrams and the following recommended guidelines:

The spa should be at or above the level of the pool.

If the spa is attached to the pool, provide a dam between the two bodies of water to allow the spa
to overflow into the pool. If the spa is not attached to the pool, an overflow, sufficient in size to
carry a full pump-flow, must be installed at the water level in the spa.

Plumb a three-port 

Intake Valve

 on the suction-side of the filter pump, so that the center port of

the valve is connected to the pump inlet. Connect the spa suction to one side of the Intake Valve,
and the pool suction to the other side.

Plumb a three-port 

Return Valve

 on the return-side of the heater, so that the return water will

enter the valve through the center port.

Connect the spa return to one side of Return Valve, and the pool return to the other side.

If required, install a spa make-up line (consisting of a manual gate or ball valve, for elevated
spas install a check valve) to bypass the pool return line.  This will enable some of the
chemically-balanced water from the pool to cycle through the spa. The manual valve will allow
the amount of bypass to be adjusted.

If the spa is to be constructed in concrete, special provision should be made at this time for the
installation of the 

Spa-Side remote Control

.

Select a convenient location in the deck or above water level in the spa wall (where the
Spa-Side remote will not be submerged by the spa water), and install a 6 in. to 12 in. length of
one inch PVC pipe to provide a receptacle for the Spa-Side remote.  The pipe should be level
and protrude beyond the finished surface of the spa. It will be cut back later at installation time.
Reduce the pipe size down to ½ in. or ¾ in. conduit, and run it to the proposed Load/Power
Center location at the equipment pad. Use sweep elbows for turns.

The Spa-Side remote will not be installed until the spa construction is completed.

For systems which incorporate a skimmer, it is possible to balance the amount of suction
between the skimmer and main drain for maintenance purposes. This is easily accomplished by
installing a manual three-port mixing valve at the suction line. Plumb one port to the skimmer and
the other to the main drain.

If a “non-booster pump” pressure-side pool cleaner is being used, plumb a manual three-port
valve between the filter pump and filter, with the third port plumbed to the pool cleaner line, and
install a motorized two-port 

Pool Cleaner Valve

 at this line.  The motorized valve will

automatically open whenever the Control System activates the pool cleaner.

If a booster pump pool cleaner is being used, plumb the booster pump so that its suction-side is
connected to the pool return, after the heater, and as close to the ground as practical.

1

2

3

4

5

6

7

8

Содержание Pool and Spa Control System

Страница 1: ...IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS pool spa control system IntelliTouch Pool and Spa Control System Personality Kit Installation Guide...

Страница 2: ...Pentair Water Pool and Spa Inc and or its affiliated companies in the United States and or other counties Crestron is registered trademark of Crestron Inc AMX is registered trademark of AMX Inc Liton...

Страница 3: ...520502 7 Digital Wireless Tablet iTC45 Kit P N 520503 7 IntelliTouch ScreenLogic Interface Accessory Kits 7 Installation Steps Summary 8 Tools required 8 Accessory Equipment 9 Plumbing Requirements 10...

Страница 4: ...ng the auxiliary relays 32 Solar System Installation 33 Solar System Start Up 33 System Wiring Diagram Power Center Load Center 34 Glossary 36 Technical Support Sanford North Carolina 8 A M to 5 P M E...

Страница 5: ...effects of hyperthermia include 1 Unawareness of impending danger 2 Failure to perceive heat 3 Failure to recognize the need to leave the spa 4 Physical inability to exit the spa 5 Fetal damage in pre...

Страница 6: ...ional state and local codes 2 Install to provide drainage of compartment for electrical components 3 If this system is used to control underwater lighting fixtures a ground fault interrupter GFCI must...

Страница 7: ...mmer Module P N 520406 can be installed for use to dim any high voltage incandescent light such as Pentair Amerlite and Pentair SpaBrite lights The dimmer module supports multiple lights from 100 watt...

Страница 8: ...nvenience of motorized valves for water flow separation between pool and spa The Personality Kit models are i5 3 P N 520505 Four auxiliary circuits plus filter pump operation create a Feature circuit...

Страница 9: ...l Panel Includes a motherboard and a Personality circuit board Power Relays Models i5 3 i5S 3 no relays i7 3 Qty 2 i9 3 i9 3S Qty 4 i10 3D Qty 5 i5x no relays i10x 5 relays Valve Actuators Qty 2 Model...

Страница 10: ...520501 Includes Wireless Personal Digital Assistant PDA with 3 5 color touch screen custom configured for IntelliTouch systems wireless router and a Protocol Interface Adapter iTC35 Kit P N 520502 In...

Страница 11: ...have system control anywhere around the home or yard Powered by a rechargeable lithium ion battery Includes a cradle for recharging The MobileTouch control panel without the Transceiver antenna P N 52...

Страница 12: ...of IntelliTouch pool spa systems The Tablet is custom configured for IntelliTouch systems Indoor Control Panel This control panel consists of a 3 75 monochrome backlit LCD and connects to the Persona...

Страница 13: ...t and AC adapter Wireless router 802 11b g with AC adapter Protocol adapter IntelliTouch ScreenLogic User s Guide CD ROM containing IntelliTouch ScreenLogic PC user interface software Digital Wireless...

Страница 14: ...n the Outdoor Control Panel model i5 i5S none i7 3 Qty 2 i9 3 i9 3S Qty 4 i10 3D Qty 5 Install Valve Actuators page 19 Install the valve actuators on the valve assembly and connect to the Personality...

Страница 15: ...t 520354 Colored Faceplate Kit for recessed mount Tan Grey or Black with label set 520335 Mud box recessing iS10 into deck or tile 520138 Indoor Control Panel White 520198 Two Speed Three HP Relay up...

Страница 16: ...If the spa is to be constructed in concrete special provision should be made at this time for the installation of the Spa Side remote Control Select a convenient location in the deck or above water le...

Страница 17: ...igher than 25 ft Glazed solar panels require a drain valve model HW 5B to allow draining of the panels This prevents damage from overheating water Install a drain valve at the solar feed line and conn...

Страница 18: ...24 SOLAR PUMP VACUUM RELIEF WATER SENSOR SKIMMER FILTER PUMP FILTER MAIN DRAIN HW 5B WATERFALL POOL LIGHT POOL 7 3 8 5 FREEZE SENSOR LOAD CENTER or POWER CENTER SOLAR SENSOR HEATER CVA 24 VACUUM RELI...

Страница 19: ...ed Hydraulic Schematic for Single Body System INTELLICHLOR 2 INTELLICHLOR SCG Check Valve MobileTouch Wireless Controller MobileTouch Wireless Controller IntelliTouch EasyTouch SunTouch Load Power Cen...

Страница 20: ...g the cover panel Power Center without Sub panel The Power Center is connected to an electrical circuit breaker panel Sub panel installed at the equipment pad The AC power is provided from the Main pa...

Страница 21: ...about using multiple Power Load Center refer to the IntelliTouch Systems User s Guide P N 520102 and the IntelliTouch Installation Guide P N 520101 Circuit breaker base 125 AMP Sub panel Grounding scr...

Страница 22: ...hes and open the front door of the Power Load Center 2 Remove the screws securing the high voltage cover panel and remove it from the enclosure 3 Remove the Outdoor Control Panel from the Personality...

Страница 23: ...l or Spa can control one temperature setting This IntelliTouch Personality Kit can control up to 10 pumps and or lighting circuits plus two heater circuits The Personality Kit includes eight auxiliary...

Страница 24: ...g up through the holes into the high voltage compartment to the Personality board 3 Insert each auxiliary relay plug into the one of the two pin sockets beginning with AUX5 AUX6 AUX7 and AUX8 on the P...

Страница 25: ...lve B actuator cable plug into the RETURN three pin socket on left side of the Personality board For wiring details refer to the System Wiring Diagrams page 32 and 33 Excess cable can be coiled in the...

Страница 26: ...shaded area to assure proper temperature readings The main screen displays the current ambient air temperature 2 Route the wire through the low voltage raceway to the motherboard 3 Fasten the cable to...

Страница 27: ...re rated wire for connection to the heater When connecting wires inside the heater be cautious of HOT internal parts of the heater Refer to the minimum temperature rating for wires recommended by the...

Страница 28: ...nting holes 1 The Control Panel is 5 in wide Using the cutout template below mark the three screw locations on the wall for the mounting holes Drill the three mounting holes If the screws are not bein...

Страница 29: ...e GND or 15V or system will not operate 3 Route the cable up through the low voltage raceway to the Personality board To access the Personality board refer to Installing the Outdoor Control Panel page...

Страница 30: ...ng length of the communication cable out of the house wall 2 Drill the flathead screw provided through the mounting sheave and into the wall 3 Remove the control panel front cover From the front of th...

Страница 31: ...ol panel on the wall Slide the control panel back plate over the mounting sheave and slide down Rotate back plate as necessary to make level The bottom mounting holes should be visible through cutouts...

Страница 32: ...e main power off at the Load Center or Power Center 2 Remove the two retaining screws located on the underside of the transceiver Carefully slide the transceiver case up and off the Transceiver back p...

Страница 33: ...etaining screws are not secured or a new hole is drilled for the cable and not sealed Do not seal drain holes Transceiver Module Screw terminals Back plate Retaining screws Transceiver Circuit Board C...

Страница 34: ...the left side of the Personality board For wiring details refer to the Wiring Diagrams for models i5 i7 3 and i9 3 page 32 and 33 Note Multiple wires may be inserted into a single screw terminal Using...

Страница 35: ...ystem Control LEDs will be lit solid Wait a few seconds then press the V button or 1 button 3 The three red System Control LEDs and the auxiliary button LEDs will begin cycling Wait until the LEDs sto...

Страница 36: ...uch controller is now ready to operate the IntelliTouch system The Service Personnel screen will be displayed 8 Press Exit to return to the main screen or proceed with Step 9 if you are adding multipl...

Страница 37: ...y charged and is now operating on AC power from the cradle Note If the battery requires replacement only use Pentair replacement battery P N 520815Z Using the MobileTouch Wireless Controller The range...

Страница 38: ...nction Press the SYSTEM CONTROL button to set the system in AUTO mode when done System Test The following describes how to test the Outdoor Control Panel to activate the heater valves and pumps This t...

Страница 39: ...feed line through a check valve to a zero psi point such as pool fill line or jet air intake Solar System Start Up 1 Switch power on to the IntelliTouch Load Center 2 If pool cleaner protection has be...

Страница 40: ...34 IntelliTouch Personality Kit Installation Guide System Wiring Diagram Power Center...

Страница 41: ...35 IntelliTouch Personality Kit Installation Guide System Wiring Diagram Load Center...

Страница 42: ...e of Power Load Center for low voltage cabling MobileTouch Controller Wireless controller for the IntelliTouch Systems with all the functionality of the Indoor Control Panel Mud Box Enclosure to provi...

Страница 43: ...37 IntelliTouch Personality Kit Installation Guide Notes...

Страница 44: ...38 IntelliTouch Personality Kit Installation Guide Notes...

Страница 45: ......

Страница 46: ...P N 520101 Rev D 520101...

Отзывы: