background image

1485 Jacobs Rd.

Deland, FL 32724

386.738.7307

P/N 53-00375-376 Rev. C 032619

www.intellitec.com

Intellitec

SERVICE MANUAL

MPX Sofa Controller

200/400

I.

II.

III.

IV.

Sofa doesn't move in one or in either direction.

A. The sofa may be jammed. Check for mechanical obstructions and clear path.

B. Power may not be coming from the fuse block. Check for 12 volts on the 12 volt input.

If there is not 12 volts, replace fuse F1.

C. The ground connection may be missing. Check and repair the ground connection.

D. Switch wiring may be faulty. Momentarily ground MPX line. The relay(s) should close

and the sofa should slide forward on the Model 400 and go up on the Model 200. If
not, check for power at the terminals of J1. One terminal should have 12 volts. If there
is not 12 volts, replace the control.

E. Disconnect J1. Press switch. If the relays "click", check wiring and motors.

F. The motor wires may be disconnected or broken. Check and repair the wiring.

Sofa doesn't move to mechanical stops.

A. The stop current may be mis-adjusted. Re-adjust the Stop control to a higher level.

(Warning: Raising this setting too high may cause opening of the circuit protection.)

Sofa moves in wrong direction from indication of the switch.

A. The motor wires may be connected improperly. Remove and re-connect the sofa motor wires.

The relays chatter.

A. The controller may not be grounded properly. Repair or replace the ground wire.

J1-1

Recline Motor Common

J2-1

Recline Motor Common

J1-2

Slide Motor Common

J2-2

Recline Motor +

J1-3

Slide Motor +

J1-4

Recline Motor +

J2-1

Ground

J1-1

Ground

J2-2

MPX bus

J1-2

MPX bus

J2-3

+12 volt power input

J1-3

+12 volt power input

Model 400

Model 200

Pin

Function

Pin

Function