background image

 

 

7

 

0: black hot      1: white hot 

5

ZOOM

Y/N 

            Zoom status     

N

no zoom

default

            Y

Zoom 2 times   

6

Alarm range

X   

show the range of alarm

From 1 to 6, default is 4

 

7

  Setup :                 

Press key “FOCUS+” or “FOCUS-”

show the password dialogue 

Press

 

  “FOCUS+

FOCUS-

FOCUS+

FOCUS-

FOCUS+

FOCUS-” to enter sub menu dialogue   

Note 

 

 

All parameters are save automatically after exit   

 

The camera will run the last setup after reboot   

 

2.2 Sub-menu operations 

In the main menu, move the cursor to “setup” 

press key “FOCUS+” or “FOCUS-” show the password 

dialogue

Input the password 

refer to Pic 2 

 

 

 

     

Press key 

“FOCUS+

FOCUS-

FOCUS+

FOCUS-

FOCUS+

FOCUS-”

to enter 

refer to Pic 3

 

Pic 2 

Содержание ThermalTronix TT-1009L-BFTC

Страница 1: ...0 ThermalTronix TT L BFTC Series Thermal Imaging Camera User Manual...

Страница 2: ...If the internal connection is broken during the assembly process or the apparatus is damped rain wet the performance will be reduced and even the device will be damaged Make sure that the power contro...

Страница 3: ...1 3 Interface definition 3 1 4 Protocol setup 4 1 5 Function key chart 4 1 6 Guide for call the Preset 4 2 Operations 6 2 1 Main menu 6 2 2 Sub menu operations 7 2 3 COM sub menu 9 2 4 Configuration s...

Страница 4: ...LCO P protocol Athermalized focus free lens Weatherproof IP66 1 2 Applications Road monitoring perimeter guard channel management marine reconnaissance patrol etc 1 3 Interface definition The control...

Страница 5: ...t A call preset to popup the menu Call preset 100 popup menus and press key LENS to change the items B call preset to setup the alarm range Call preset 101 to switch the alarm range C call preset to c...

Страница 6: ...eset 110 changes to baud 9600 E call preset to change the address of thermal camera Call preset 111 to changes to address 1 Call preset 112 to changes to address 2 Call preset 113 to changes to addres...

Страница 7: ...change the value where the cursor is Auto save when exit 1 Auto XXX Display the current image auto mode Three options 0 manual gain manual brightness 1 manual gain auto brightness 2 auto gain auto br...

Страница 8: ...gue Press FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS to enter sub menu dialogue Note All parameters are save automatically after exit The camera will run the last setup after reboot 2 2 Sub menu operations I...

Страница 9: ...he password FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS enter the level 3 sub menu 4 Test press key FOCUS or FOCUS show the password dialogue Input the password FOCUS FOCUS FOCUS FOCUS FOCUS FOCUS enter the l...

Страница 10: ...of Gain setup as C 1 2 C Close default 1 2 Open relatively Gain grade 9 Default factory default including auto polarity alarm range calibration image alarm alarm pixel Number 10 Exit XXX press key FOC...

Страница 11: ...s key LENS to exit Default Add 1 Baud 2400 Protocol PELCO D 2 4 Configuration sub menu First Without the menu call preset 100 Enter the main menu In the main menu press the key LENS move the cursor to...

Страница 12: ...change the value where the cursor is Auto save when exit 1 G XXX Range 0 255 2 B XXX Range 0 255 3 Exit Press key LENS to exit Default G 32 B 188 2 5 Alarm Valve sub menu First Without the menu call p...

Страница 13: ...to save when exit 1 Alarm range X Range 1 6 2 Alarm Valve XXX Show the status of Alarm Valve 3 Alarm pixel Number XXX Show and setup for minimum l number of alarm Such as alarm Number 2 so the alarm p...

Страница 14: ...1 1 Focus Athermalized focus free Free focus range 0 8m 3m 12m 23m NETD 100mK Gain Brightness adjustment Manual brightness gain auto brightness manual gain auto brightness gain Functions Polarity inve...

Отзывы: