12
RS485 can’t control TT-1007D-MARINE direction when opening gyro or tracking function
Operation key
function
default state
direction up
Turning up control
direction down
Turning down control
direction left
Turning left control
direction right
Turning right control
preset preset
setting key
Preset setting
preset preset
delete key
Preset delete
preset preset call
key
Preset call
preset 21+preset call key
Manual video
switch(CCD/thermal camera)
-
preset 22+preset call key
Automatic video
switch(CCD/thermal camera)
√
preset 23+preset call key
Open/close wide dynamic
close
preset 24+preset call key
Open automatic wide dynamic
close
preset 25+preset call key
Open/close BLC
close
preset 26+preset call key
Open/close image flip
close
preset 27+preset call key
Open/close digital noise reduction
close
preset 28+preset call key
Open/close image freeze
close
preset 29+preset call key
Open/close image anti-shake
close
preset 37+preset call key
Open demist
-
preset 38+preset call key
Close demist
√
preset 39+preset call key
Open/close digital zoom
close
Ppreset call key
OSD open/close
open
preset 42+preset call key
left area scanning
-
preset 43+preset call key
Right area scanning
-
preset 48+preset call key
Intermittent scanning
-
preset 49+preset call key
Area scanning
-
preset 50+preset call key
Automatic cruise
-
preset 51+preset call key
Continuous scanning
-
preset 52+preset call key
Clear all settings
-
preset 53+preset call key
Restore factory settings
-
preset 57+preset call key
Open help tips/help tips page
-
preset 58+preset call key
Close help tips
-
preset 59+preset call key
PTZ speed-fast
-
preset 60+preset call key
PTZ speed-medium
√
preset 61+preset call key
PTZ speed-slow
-
preset 62+preset call key
CCD camera address -1
-
preset 63+preset call key
CCD camera a1
-
preset 65+preset call key
Thermal camera lens enter into safety
position
-
preset 66+preset call key
Thermal camera lens exit safety
position
-
*
1
Note: <20 are normal presets, others are special function preset.
*
2
PTZ scan at a constant speed in the horizontal direction and within the set area range. PTZ
won’t perform any action if not set the left and right border area scan.
*
3
PTZ automatically move back and forth at predetermined time according to preset point
sequence, this feature is only work for 0 to the 20th preset.