Intellisystem IT-SDS-304-T-4D Series Скачать руководство пользователя страница 8

 

 

8

 

 

System statue LED

 

LED 

Indicate

 

Description

 

PWR 

ON

 

Power    is connected/Function 

natural 

OFF

 

Power is disconnected or function 

nu-natural 

RUN 

Flashing 

System Running steadily 

OFF 

System  did  not  run  or  running 

un-steadily 

ON 

System Running un-steadily 

LINK 

ON

 

Ethernet port connect successfully

 

Flashing

 

Ethernet port has data transmission

 

OFF

 

Ethernet port connect unsuccessfully

 

RX1~RX4 

OFF

 

None data receive

 

Flashing

 

In receiving data

 

TX1~TX4 

OFF

 

None data transmit

 

Flashing

 

In transmitting data

 

 

Installation

 

          Before installation, confirm that the work environment meet the installation require, including the power needs  and abundant space. Whether 

it is close to the connection equipment and other equipments are prepared or not.   

1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI. 

2. Examine the cables and plugs that installation requirements. 

3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.   

4. Screw, nut, tool provide by yourself. 

5.Power need: 5VDC power inputs 

6. Environment: -40°C to 85°C 

    Relative humidity 10% to 95% 

7. Installation: support 2 kinds of wall mounting installation  

 

Wiring Requirements 

Cable laying need to meet the following requirements,

 

1. It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying;  

2. It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable laying;  

3. The required cable specification, quantity, direction and laying position need to match construction requirements, and cable length depends 

on actual position; 

4. All the cable cannot have break-down and terminal in the middle; 

5. Cables should be straight in the hallways and turning; 

Содержание IT-SDS-304-T-4D Series

Страница 1: ...net support cross gateway and cross router user can can flexible configure IP address server and client mode data bag size etc IT SDS 304 T 4D series adopts EMC protection design can work in rugged en...

Страница 2: ...working mode Support TCP UDP ARP ICMP DHCP and DNS protocol Support link automatic when network cut off function Support cross gateway and cross router communication Provide Windows configuration too...

Страница 3: ...Power indicator 2 Running statues indicator 3 Network connection statues indicator 4 Factory default button DEF 5 COM1 COM4 receive data statues indicator 6 COM1 COM4 transmit data statues indicator 7...

Страница 4: ...Running statues indicator 3 Network connection statues indicator 4 Factory default button DEF 5 COM1 COM4 receive data statues indicator 6 COM1 COM4 transmit data statues indicator 7 Company name pro...

Страница 5: ...5 Dimensions Unit mm Power input IT SDS 304 T 4D series provide DC power input voltage input is DC power adapter specification is internal size 2 5mm external size 5 5mm DC...

Страница 6: ...tic MDI MDI X operation can connect the PC Server Converter and HUB Pin 1 2 3 6 Corresponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T...

Страница 7: ...Data terminal ready 8 DCD Data carrier detect IT SDS 304 T 4D 4DI RS 485 Back panel provide 3 81mm 4bit industrial terminal block the PIN define is as follows RS 485 PIN Define 1 D A 2 D B RS 422 PIN...

Страница 8: ...t fountainhead or the area where in intense EMI 2 Examine the cables and plugs that installation requirements 3 Examine whether the cables be seemly or not less than 100m according to reasonable schem...

Страница 9: ...be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other...

Страница 10: ...rial port receive data indicator RX1 RX4 Power requirements Input voltage 5VDC 5 IT SDS 304 T 4D 4D RS 232 No load consumption 0 945W 5VDC Full load consumption 1 095W 5VDC IT SDS 304 T 4D 4DI RS 485...