Wiring Requirements 

Cable laying need to meet the following requirements,

 

1.It is needed to check whether the type, quantity and specification of cable match the requirement before cable laying;  

2.It is needed to check the cable is damaged or not, factory records and quality assurance booklet before cable laying;  

3.The  required cable specification, quantity, direction  and  laying position need  to match construction  requirements, and  cable  length depends  on 

actual position; 

4.All the cable cannot have break-down and terminal in the middle; 

5.Cables should be straight in the hallways and turning; 

6.Cable should be straight in the groove, and cannot beyond the groove in case of holding back the inlet and outlet holes. Ca bles should be banded 

and fixed when they are out of the groove; 

7.User cable should be separated from the power lines. Cables, power lines and grounding lines cannot be overlapped and mixed when they are in 

the same groove road. When cable is too long, it cannot hold down other cable, but structure in the middle of alignment rack;  

8.Pigtail  cannot  be  tied  and  swerved  as  less  as  possible.  Swerving  radius  cannot  be  too  small  (small  swerving  causes  terrible  loss  of  link).  Its 

banding should be moderate, not too tight, and should be separated from other cables;  

9.It should have corresponding simple signal at both sides of    the cable for maintaining. 

 

Specifications

 

Ethernet port 

Standard: 10Base-T, 100Base-TX 

Protocol: Support TCP, UDP, APR, ICMP and DHCP 

Signal: Rx+, Rx-, Tx+, Tx- 

Speed: 10/100Mbps 

Working: Full-duplex and half duplex 

Working mode: Support TCP Server and Client, UDP, TCP Auto and Real COM driver 

Transfer distance: 100m 

Connector: RJ45 

Serial port 

Serial port number: 8 port RS-232 or 8 port RS-485/422 

RS-232 signal: DCD, RXD, TXD, DTR, GND, DSR, RTS,       

                              CTS 

RS-485 signal: D+, D-, GND 

RS-422 signal: T+, T-, GND, R+, R- 

Parity bit: None, Even, Odd, Space, Mark 

Data bit; 5bit,6bit,7bit,8bit 

Stop bit: 1bit,1.5bit,2bit 

Band rate: 300bps

115200bps 

RS-232 Transfer distance: no more than 15m  

RS-232 connector: RJ45 

RS-485 transfer distance: 1200m 

Содержание IT-SDS-3016-T-16D Series

Страница 1: ...re coming true by WEB or Telnet support cross gateway and cross router user can can flexible configure IP address server and client mode data bag size etc IT SDS 3016 T 16D series adopts EMC protection design can work in rugged environment Packing list The first time use this product please check the packaging is intact or not and the attachment is complete or not at first IT SDS 3016 T 16D series...

Страница 2: ...P SOCKET access Support Windows serial driver mode Support virtual serial COM port access and Network interruption automatic recovery Provide Windows configuration tools for easy to use easy to bath install Support WEB and serial configuration No fan low consumption design Industrial grade design IP30 protection grade Working temperature 25 70 Storage temperature 30 85 Panel design Main view IT SD...

Страница 3: ...product series 2 Electrical port connection indicator 3 Device running status indicator 4 Power PWR indicator 5 Serial port running indicator 6 Default factory DEF button 7 Power input port 8 Serial port COM1 COM16 9 10Base T 100Base TX Ethernet port ...

Страница 4: ...supply input port the range is 85 265VAC Important notice 1 Power ON operation Please connect to the device at first and then connect to the power supply with power cable 2 Power switch means power ON O means power OFF 3 Power OFF operation Please disconnect the power supply at first and then disconnect the device ...

Страница 5: ...ponding connection in MDI 1 3 2 6 3 1 6 2 are used as cross wiring in the MDI X port of Converter and HUB 10Base T 100Base TX are used in MDI MDI X the define of Pin in the table as below NO MDI signal MDI X signal 1 TX RX 2 TX RX 3 RX TX 6 RX TX 4 5 7 8 Note TX Transmit Data RX Receive Data Not use MDI straight through cable MDI X Cross over cable MDI MDI X Self adapt function can let user did no...

Страница 6: ...nsmit data 2 RXD Received Data 3 RTS Request to send 4 CTS Clear to send 5 DSR Data set ready 6 GND Signal ground 7 DTR Data terminal ready 8 DCD Data carrier detect IT SDS 3016 T 16D 16DI RS 485 P 85 265VAC RS 485adopts 5 bit 5 08mm terminal block The PIN define is as follows RS 485 port PIN Define 1 D A 2 D B 3 GND 4 5 RS 422 port PIN PIN define 1 T A 2 T B 3 GND 4 R A 5 R B 1 8 ...

Страница 7: ...lashing In receiving data RX1 RX16 OFF None data transmit Flashing In transmitting data Installation Before installation confirm that the work environment meet the installation require including the power needs and abundant space Whether it is close to the connection equipment and other equipments are prepared or not 1 Avoid in the sunshine keep away from the heat fountainhead or the area where in...

Страница 8: ...n they are in the same groove road When cable is too long it cannot hold down other cable but structure in the middle of alignment rack 8 Pigtail cannot be tied and swerved as less as possible Swerving radius cannot be too small small swerving causes terrible loss of link Its banding should be moderate not too tight and should be separated from other cables 9 It should have corresponding simple si...

Страница 9: ... 220VAC IT SDS 3016 T 16D 16DI RS 485 P 85 265VAC No load consumption 8 8W 220VAC Full load consumption 10 1W 220VAC Mechanical Shell IP30 protection metal shell Installation 1U 19 rack mount Weight 2500g Size L W H 441 6mm 207 9mm 44 6mm Environment limits Working temperature 25 70 Storage temperature 30 85 Relative humidity 5 95 non condensing Standards EMI EN 55022 Class A FCC Part 15 Subpart B...

Страница 10: ...10 Vibration IEC 60068 2 6 Warranty Warranty time 5 years Certificates CE FCC RoHS UL508 pending ...

Отзывы: