LED indicator
】
The LED indicator on the front panel of IT-SDS-3016-T-16D series can indicate the running system and the operation status, which makes it easy to
find and solve problems, the specific meaning of indicator are shown in the table.
System status LED
LED
Indicate
Description
PWR
ON
Power is connected/Function
natural
OFF
Power is disconnected or function
nu-natural
RUN
Flashing
System Running steadily
OFF
System did not run or running
un-steadily
ON
System Running un-steadily
LINK
ON
Ethernet port connect successfully
Flashing
Ethernet port has data
transmission
OFF
Ethernet port connect
unsuccessfully
TX1~TX16
OFF
None data receive
Flashing
In receiving data
RX1~RX16
OFF
None data transmit
Flashing
In transmitting data
Installation
】
Before installation, confirm that the work environment meet the installation require, including the power needs and abundant space.
Whether it is close to the connection equipment and other equipments are prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Screw, nut, tool provide by yourself.
5.Power need: 5VDC power inputs
6. Environment: -25
°
C to 70
°
C
Relative humidity 10% to 95%
7. Installation: 1U 19” rack mount installation
1. Please put the hangers to device‘s both side, then fix it into rack.
2. Use the card install at the bottom of the device.