27
4.2.6
、
Network configuration
1
)
Network port
a)
Data port: set the data port, the device will restart automatically after changed (default 3000, 0-65535 optional).
b)
Web Port: Set Web port, the device will restart automatically after changed (default is 80, 0-65535 is optional).
c)
Onvif Port: Set Onvif port, the device will restart automatically after changed (default 2000, 0-65535 optional).
d)
Soap Port: Set Soap port (default 1936, 0-65535 optional).
e)
RTMP Port: Set RTMP port (default 1935, 0-65535 optional).
f)
RTSP Port: Set RTSP port, the device will restart automatically after changed (default 554, 0-65535 optional).
g)
Visca Port: Set Visca port, the device will restart automatically after changed (default 3001, 0-65535 optional).
Click on the "Save" button to display the "Save successful" message, then valid.
2) Ethernet parameters
a)
DHCP: Set whether to open to obtain IP automatically. The machine will restart automatically after change (off by default)
b)
IP Address: Set the IP address, the device will restart automatically after changes (default 192.168.5.163).
c)
Note
: Here is the IP address of the web page of the sign-in address
d)
Subnet Mask: Set the subnet mask (default 255.255.5.0).
e)
Default Gateway: Set the default gateway (default 0.0.0.0).
f)
Physical Address: Set the physical address (the parameter is read-only but can not be modified).
Click on the "Save" button to display the "Save successfully" message, then the set is to take effect (Note: To prevent IP conflicts
When modify).
3) DNS parameters
a)
Preferred DNS server: set the preferred DNS server. (Default 0.0.0.0).
b)
Alternate DNS server: Alternate DNS server settings. (Default 0.0.0.0).
c)
Click on the "Save" button to display the "Save successfully" message, then the set is to take effect.
4) GB28181
a)
Switch: set whether open GB28181, can check
b)
Time Synchronization: whether synchronization time is set, you can check
c)
Stream Type: stream type setting (the default main stream, secondary stream optional)
d)
Sign effective time (in seconds): 3600 Range 5-65535
e)
Heartbeat time (seconds): 60 Range 1-65535
f)
Register ID: 34020000001320000001
g)
Register User name: IPC
h)
Register Password: 12345678
i)
Equipment ownership: Users can add their own
j)
Administrative regions: Users can add their own
k)
Alarm Zone: Users can add their own
l)
Equipment installation address: Users can add their own
m)
Local SIP Port: 5060 Range 0-65535
n)
GB28181 Server Address: IP address of the computer
o)
Server SIP Port: 5060 Range 0-65535
p)
Server ID: 34020000002000000001
q)
Click on the "Save" button to display "Parameter saved successfully" message, set to take effect