DISARMING THE SYSTEM

Enter the protected area by the authorised entry route.  A single
continuous tone will be heard from any internal speakers and from
keypads.  Proceed directly to the keypad and enter your user code.
The system will disarm.

While the panel is in Alarm

Go directly to the keypad and insert your user code, the system
will disarm and the sounders stop, the zone/s will light on the
control panel to indicate the cause of the alarm.   Refer to page 7
to reset the alarm.

TAMPER FAULTS

The control panel has tamper circuits giving protection from
unauthorised tampering.  If the tamper circuit is broken during the
unset period any internal speakers will activate and the tamper and
possibly a zone LED will illuminate.  Proceed directly to the keypad
and enter your user code, the internal sounder will stop.  Refer to
page 7 to reset the alarm.  After reset, if the tamper light remains on
then the cause of the tamper condition is still present.  Refer to fault
clearing on page 7.

PERSONAL ATTACK

If your system has a personal attack button fitted this will be linked
into the alarm system as a 24hr device.  The PA button will be
active all the time. If the PA button is pressed, all the sounders will
operate and the zone programmed as PA will indicate on the
keypad.  Enter your user code, the sounders will stop.  Go to the
personal attack button(s) and reset with the special key provided.
Refer to page 7 to reset the alarm.  If the light remains on refer to
fault clearing on page 7.

Note:

 If the panel is armed and a PA is activated, you will need to

disarm the system as explained above.

Personal Attack from remote keypad

If the Alarm Company has programmed personal attack on the

keypads, pressing and holding the 

*

 and 

#

 keys together for 3

seconds activates the system as if a PA button was pressed. The
only difference is that the LEDs will scroll.  Entering the user
code will stop the sounders.  Refer to page 7 to reset the alarm.

DISARMING
THE SYSTEM

WHILE PANEL
IS IN ALARM

TAMPER
FAULTS

PERSONAL
ATTACK

PERSONAL
ATTACK
FROM
REMOTE
KEYPAD

Содержание SECURIT 900C

Страница 1: ...USER MANUAL SECURIT 900C CONTROL PANEL ...

Страница 2: ...iceable parts inside this product STANDARDS This unit conforms to EMC directive 89 336 EE LVD 73 23 EEC R TTE CTR21 This unit has been tested to the required standards for emission immunity and LVD regulations as set out by the EU This unit conforms to the requirements of BS 4737 part 1 1986 which relates to security control equipment PRODUCT DESCRIPTION The control panel is an 8 zone programmable...

Страница 3: ...med for quick set press 1 to full set the system Selecting Part Set Enter user code and press 2 If your system has been programmed for quick set press 2 to part set the system The exit sounds are programmable by the Alarm Company only the fault pulse tone and set acknowledge bleeps may sound Selecting Home Set Enter user code and press 3 If your system has been programmed for quick set press 3 to ...

Страница 4: ...mper condition is still present Refer to fault clearing on page 7 PERSONAL ATTACK If your system has a personal attack button fitted this will be linked into the alarm system as a 24hr device The PA button will be active all the time If the PA button is pressed all the sounders will operate and the zone programmed as PA will indicate on the keypad Enter your user code the sounders will stop Go to ...

Страница 5: ...eps If the panel does not accept your code then there may be a conflict with another user code The panel will abort the code change and retain the old code Three beeps will be heard from the keypad Try again with a different code To change user 2 code go through the above procedure but press 8 followed by 2 for user 2 then the required code The other users are changed in the same way using existin...

Страница 6: ...pad all zones that have responded will be illuminated To Cancel enter a user code and wait for two beeps CHIME The control panel offers the ability to have chime on a zone when unset This feature will emit two beeps via the internal speaker and keypad buzzer whenever a zone is activated To enable chime enter the user code press the 9 key and the number key that represents the zone s you want on ch...

Страница 7: ...t Type Tampers Alarms Customer Engineer Technistore Assistance telephone number FAULT CLEARING SYMPTOM CAUSE ACTION Zone LED on continuously Alarm activated Reset the panel Tone pulsing on exit Zone in Fault Leave protected area and wait for tone to go continuous Tone continues to pulse after exit Zone in Fault Check for open doors or a detector is in fault call your Alarm Company Alarm triggers o...

Страница 8: ...ONE AREA COVERED 1 2 3 4 5 6 7 8 Please Note IntelliSense are always endeavouring to improve quality and specification of all its products and may alter or amend this product and instructions without notice IntelliSense 2002 Printed Manufactured in the UK by IntelliSense Document No II1 0901 Rev 1 0 ...

Отзывы: