background image

 

 

 

Intellisense Systems Inc. 

Page 4

 

– Rev 02.25.21

 

  Micro Weather Station (MWS

®

) User Guide – Commercial Series 

INSTALLATION INSTRUCTIONS 

 

The MWS comes equipped with a standard ¼-20 threaded “camera” mount feature on its baseplate. 
Intellisense recommends and offers two proven mounting solutions for the MWS to meet the needs of 
lightweight and rugged portable deployment: 

 

1.

 

MWS Tripod – a low profile and fixed-height collapsible tripod with gimbal for leveling 

 

2.

 

MWS Pole Mount – a short, lightweight pole to temporarily affix to existing poles and structures 

 

For all mounting solutions, the mount must be weighted down or rigidly affixed to a substrate to prevent the 
dislodgement or accidental tipping of the system during high winds or other unintended incidents. Please 
note: the mounting solution should be rigidly emplaced 

before

 the MWS is installed and turned on. 

 

MWS Installation – Tripod

 

 

1.

 

Place the tripod on level ground with a 
clear view of the sky. 

 

2.

 

Secure the tripod to the ground with 
an anchor or weight (25-50 lb weight 
is recommended) attached to center 
eyebolt. 

 

3.

 

If possible, secure the tripod legs to 
the ground with stakes or by adding 
weights on top of nylon webbing. 

 

CAUTION:

 The MWS Tripod must be secured 

to the ground with the center eyebolt before 
attaching the MWS. 

 

 
 
 
 

MWS Installation – Pole Mount 

 

1.

 

Place the grooved side of the pole 
mount against a rigid, secure, and 
vertically oriented pole. 

 

2.

 

Secure the pole mount using the 
included zip ties. 

 

 

 

1.  

2.  

2.  

1.  

3.  

Содержание MWS Commercial C400

Страница 1: ...Intellisense Systems Inc 1 Installation Guide 20600 Gramercy Place IG AWARE Flood 11 2019 Torrance CA 90501 1821 Revision A 310 320 1827 Micro Weather Station MWS User Guide Commercial Series...

Страница 2: ...ions to follow The MWS Commercial Series At A Glance Series Name Commercial Model No C400 C500 C600 FEATURES Colors Available White Coyote Brown o o o Integrated Solar Panels Integrated NiCd Battery P...

Страница 3: ...titude 18 Debris Accumulation C500 C600 models only 9 GPS Longitude 19 Cloud Height C600 models only 10 GPS Elevation These environmental parameters are determined using inputs from a combination of s...

Страница 4: ...Install near any large objects that obstruct the unit from above Place the unit within 30 ft of any structures trees or boulders taller than the MWS Use a mounting solution that may cause the unit to...

Страница 5: ...ubstrate to prevent the dislodgement or accidental tipping of the system during high winds or other unintended incidents Please note the mounting solution should be rigidly emplaced before the MWS is...

Страница 6: ...WS requires solar or cabled charging Flashing lights Self check failure If the lights blink multiple times when the unit is first powered on then there has been a self check failure and the unit will...

Страница 7: ...ed If the first report back from your MWS when not connected to hardline power provides a low battery voltage below 5 V change the reporting mode to every 3 hours until the battery is charged to over...

Страница 8: ...le to acquire a GPS signal it will keep trying to acquire satellites before reporting weather data Make sure the unit is placed in an ideal location for operation see the Site Selection section above...

Страница 9: ...o FAA based weather stations 10 second samples taken each 30 seconds and combined to report a 5 minute average The last 4x 10 second samples are averaged to also report last 2 minute wind average Line...

Страница 10: ...to the harness 6 Reinstall the battery pack and screw the bottom plate back onto the unit Sensor and System Notes Power System The power system of the MWS consists of nickel cadmium NiCd batteries an...

Страница 11: ...le image set can be requested or scheduled based on system time with hourly images being the fastest When hourly images are requested they will always send at 56 minutes after the hour The default set...

Страница 12: ...ber 0 255 rotates back to 16 so a number below 16 means new start 2 Sample cycle number max number of cycles N 255 10 10 B Battery level 1 Battery level Volts to 2 decimals 2 Operating mode 3 Auto ima...

Страница 13: ...ak wind speed knots 2 Direction degrees GU 3 240 LD Lightning distance 1 Lightning distance nautical miles to 1 decimal or if no detections 2 Number of 5 minute detection periods with strikes detected...

Страница 14: ...l 5 Accumulation 0 99 6 Visibility millivolts 7 Visibility calibration value PW 1 25 30 346 ek 99 115 100 VI Visibility Estimated visibility in miles calculated from visibility millivolts to 1 decimal...

Отзывы: