BULK:
In this stage (full constant-current) the charger charges the battery with a constant current.
This constant current stage occurs for battery voltages between 70% to 98% (typical) of the voltage
limit
provided
in
the
Charging
Voltage
Limits
section
below.
●
ABSORPTION:
In this stage (constant-voltage) the charger charges the battery with a configured
constant voltage. This constant voltage stage occurs for battery voltages above 98% (typical) of the
voltage
limit
described
in
Charging
Voltage
Limits
section
below.
●
FLOAT: In this stage, the charger charges the battery with a reduced constant voltage.
Note:
This
stage
is
not
applicable
for
Lithium
LiFePO4
batteries.
●
FULL:
Charger
disabled,
charging
complete.
7.8
Charging
Voltage
Limits
The Battery Charger applies the appropriate Charging and Float Voltages depending on the Battery Type as
well
as
combining
automatic
Temperature
Compensation.
Battery
Type
Charging
Voltage
(V
DC
)
at
25
°
c
Float
Voltage
(V
DC
)
at
25
°
c
LEAD/GEL
14.2
13.3
CALCIUM
15.3
13.3
AGM
14.6
13.3
LITHIUM
LiFePO4
14.6
N/A
Note:
For
Lithium
LiFePO4
batteries
there
is
no
FLOAT
stage.
7.9
Charging
Complete
When
charging
finishes
the
HOME
screen
will
show
the
charging
source
with
a
FULL
message.
At
this
point
the
Battery
Charger
will
automatically
shut
off
and
there
is
no
risk
of
overcharging
the
battery.
Page