12

Maintenance

Remove the V-Bank Main Filter and High Energy Grid Assembly

Refer to page 11 for proper instructions.

To clean the wires, use a lint free swab, either dry or moistened with denatured alcohol, clean along the length of each 

wire and spring clips. 

Clean the inner surfaces of the High Energy Grid material using a lint cloth moistened with denatured alcohol. 

Clean the High Energy Grid surface by vacuuming between the wires using a small vacuum attachment or by using a lint 

free cloth, either dry or moistened with denatured alcohol. Take care to avoid leaving large fibers snagged on the wires, 

control grid, or other components of the High Energy Grid. 

Make sure that any contaminant that falls to the bottom of the filter unit is removed.

In extreme cases, it may be necessary to remove the wires from the springs attached at each end to the power distribution 

bars, thus allowing complete access to the inside of the High Energy Grid assembly for cleaning  

as previously described.  It is recommended that the manufacturer be contacted for detailed instructions should this step 

appear necessary.

Vacuum the bottom of the filter seal plate section and of the filter unit to remove any particles dislodged during cleaning. 

Reinstall the High Energy Grid, V-Bank Main Filter and Filter Access Door as previously instructed.

Do not install the High Energy Grid to the V Bank Filter until wires are completely dry.

CLEANING THE UNIT

Depending on contamination level, this procedure should be conducted once a year or during each filter change or if an 

electrical problem occurs.

 

Do not install the High Energy Grid to the V Bank Filter  

until wires are completely dry.

Cleaning and user maintenance shall not be made  

by children without supervision.

Содержание 950P

Страница 1: ...Operation Manual Intellipure 950P COMMERCIAL PORTABLE AIR PURIFICATION SYSTEM ...

Страница 2: ......

Страница 3: ...om Limited Warranty 4 Safety Precautions 5 Receiving and Unpacking 5 Receiving Storage System Overview 6 Unit Description Component Description Installation Procedures 7 Power Requirements Location Determination System Operation 8 Maintenance 10 13 Prefilter Replacement V Bank Main Filter Replacement Cleaning the Unit Parts List Voltage Adjustments 13 Troubleshooting 14 System Schematic 15 ...

Страница 4: ...IPPED TO OR FROM THE FACTORY OR DESIGNATED SERVICE CENTER IN CONNECTION WITH WARRANTY CLAIMS NOR DOES IT APPLY TO ANY DAMAGES OCCURRING DURING SUCH SHIPMENT C This Limited Warranty does not apply to labor for installation removal re installation and or travel or ship ping expenses and related expenses This Limited Warranty does not apply to replaceable filters LIMITATIONS Intellipure shall not be ...

Страница 5: ...rrosion and excessive heat cold Must install the Prefilter andV Bank Main Filter before turning on the unit Safety Precautions This symbol will be used throughout this manual to indicate safety checkpoints Failure to heed these warnings and notices may result in damage to the unit and or injury to personnel SAFETY PRECAUTIONS Personnel who will operate this system or those who will perform mainten...

Страница 6: ...icrons once a year UNIT DESCRIPTION The Air Cleaning System is a high performance system that utilizes patented award winning Disinfecting Fil tration System technology DFS technology electrically converts a low pressure drop filter to high efficiency while retaining the low pressure drop and longer life advantages of the base filter material Thistechnologyhasalsobeen showntoinhibitbacteriagrowtho...

Страница 7: ...purifier anywhere in the room and on a flat and level surface to allow continuous airflow to the bottom intake and out the top outlet grill For best performance it is recommended to place the air purifier at least two 2 feet from walls and other obstructions Do not place the air purifier where drapes or other objects block airflow Always lock both casters Do not run power cord under carpeting or n...

Страница 8: ... speed e Turbo mode f 1 VOC Pre filter indicator f 2 Change VOC pre filter indicator g 1 Main filter indicator g 2 Change main filter indicator h 1 VOC post filter indicator h 2 Change VOC post filter indicator i 1 DFS indicator i 2 DFS deactivation indicator Disconnect power to the unit before servicing Moving Parts inside Wait 30 seconds after turning the unit off before opening the Filter Acces...

Страница 9: ...n and Sleep Mode Button are lit The unit will remain running at the speed set before Sleep Mode was activated 3 To deactivate Sleep Mode touch anywhere in the speed bar TURBO MODE 1 Touch Turbo Mode button to activate Turbo Mode 2 When activated all buttons on the On board Touch Pad are illuminated white 3 To deactivate Turbo Mode touch anywhere in the speed bar FILTER INDICATOR 1 2 3 1 When unit ...

Страница 10: ...h the direction of the air flow label fig 3 Ensure the Prefilter is firmly seated unit will not turn on without installing Prefilter correctly Return the filter access door to the unit fig 4 and fig 10 threaded pin shall be positioned into the hole of the control panel to activate safety switch The unit will not operate without safety switch activated When replacing filters use only Intellipure ce...

Страница 11: ... Main Filter fig 9 and apply High Energy Grid to the new filter Secure the High Energy Grid to the new V Bank Main Filter by turning and locking three panel clips fig 8 Slide theV Bank Main Filter and HighEnergyGrid Assemblybackintotheunit Pay attention to the Flow Direction Arrow on the filter the arrow should point towards the Supply Outlet end of the unit LockV bank filter with a flat screw dri...

Страница 12: ...xtreme cases it may be necessary to remove the wires from the springs attached at each end to the power distribution bars thus allowing complete access to the inside of the High Energy Grid assembly for cleaning as previously described It is recommended that the manufacturer be contacted for detailed instructions should this step appear necessary Vacuum the bottom of the filter seal plate section ...

Страница 13: ...ten wire WH611 Optional Part Number VOC Filter 2000 VOC Cartridge Maintenance PARTS LIST Order all parts by contacting Phone No 315 298 2904 1 800 843 3860 Fax No 315 298 6992 Email info intellipure com VoltageAdjustment In order to change the incoming voltage setting Unplug the unit Remove the front door Fig 1 Remove the electrical panel cover Fig 2 Slide voltage switch to appropriate voltage Fig...

Страница 14: ...ded Action 1 Unit will not turn ON a Ensure power cord is plugged in electrical outlet is energized b Check fuse located on the bottom of the unit Check if fuse was blown c Ensure Pre filter was installed d Ensure V Bank Main Filter is locked correctly fig 6 e Ensure High Energy Wire is connected fig 5 2 The unit turns ON but no air blows out Turn off unit and unplug the power wait 2 minutes and r...

Страница 15: ...in filter indicator is out Change main filter indicator is illuminated in red Main filter needs to be replaced Page 13 part number 6 VOC post filter indicator is out Change VOC post filter indicator is illuminated in red VOC post filter needs to be replaced Page 13 part number 7 DFS indicator is out and maintenance indicator is illuminated in red DFS Technology is turned off or High Energy Grid ne...

Страница 16: ...intellipure com ...

Отзывы: