Intellinet 560801 Скачать руководство пользователя страница 17

                   

                             

Web Managed GbE Switch 

   

 

17 

 

 

 

Содержание 560801

Страница 1: ...WEB MANAGED GIGABIT ETHERNET SWITCH WITH 4 SFP PORTS USER MANUAL MODELS 560801 560818 Model 560801 16 Port Model 560818 24 Port INT 560801 560818 UM 1112 01...

Страница 2: ...likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This device complies with Part 15 of the FCC Rules Operation is subject to...

Страница 3: ...Management Configuration 17 3 1 Status 17 3 1 1 System Information 17 3 1 2 Log 19 3 1 3 Port 21 3 1 3 1 Port Statistics 21 3 1 3 2 Port Counters 22 3 1 3 3 Port Error Disabled 24 3 1 3 4 Bandwidth Ut...

Страница 4: ...3 3 7 2 IGMP VLAN Setting 47 3 3 7 3 Multicast Database 48 3 3 7 4 Router Table 49 3 3 8 Jumbo Frame 49 3 3 9 STP 50 3 3 9 1 STP Global Setting 50 3 3 9 2 STP Port Setting 52 3 3 9 3 MST Configuratio...

Страница 5: ...6 7 Queue Remarking Status 78 3 6 8 Queue Remarking Table 79 3 7 Management 80 3 7 1 SNMP 80 3 7 1 1 SNMP Setting 80 3 7 1 2 SNMP Community 81 3 7 1 3 SNMP Trap 82 3 8 Diagnostics 83 3 8 1 Ping Test...

Страница 6: ...ed to increase business productivity by reliably supporting business applications It features a Web based GUI and supports SNMP RMON and Telnet The impressive list of features includes but is not limi...

Страница 7: ...tion for reference LED Status Operation Steady Green The switch is powered on Power Off The switch is powered off Steady Green Valid port connection Blinking Green Valid port connection and there is d...

Страница 8: ...e that your outlet standard is within this range To power on the switch plug the female end of the power cord firmly into the receptacle of the switch and the other end into an electric service outlet...

Страница 9: ...male end into the power outlet Rackmount Installation The switch may be standalone or mounted in a rack Rackmounting allows a more orderly installation when you are going to install a series of networ...

Страница 10: ...smitting receiving speeds is required To choose a suitable cable refer to the following table Media Speed Wiring 10 Mbps Category 3 4 5 UTP STP 100 Mbps Category 5 UTP STP 10 100 1000 Mbps copper 1000...

Страница 11: ...System login 1 Start your Web browser 2 Type http and the IP address of the switch for example the default management IP address is 192 168 2 1 in the Location or Address field Press ENTER 3 The logi...

Страница 12: ...to each configuration page The Graphic User Interface is as follows A Click the menu items to open submenu links and then click on a submenu link to open the screen in the main window B It shows the...

Страница 13: ...eb Managed GbE Switch 13 In the navigation panel click a main link to reveal a list of submenu links shown as the following Status Network Switching Security ACL QoS Management Diagnostics Maintenance...

Страница 14: ...s you to a screen where you can configure the switch s time settings Switching Port Setting This link takes you to a screen where you can configure settings for individual switch ports Port Mirroring...

Страница 15: ...vising the template setting of ASL ACL Index Range Setting This link takes you to a screen to setting and revising the index range setting of ASL ACL Policy Setting This link takes you to a screen to...

Страница 16: ...s you back to the factory default configuration Reboot Switch This link takes you to a screen where you can reboot the switch Maintenance Backup Manager This link takes you to a screen where you can b...

Страница 17: ...Web Managed GbE Switch 17...

Страница 18: ...n and status 3 1 1 System Information In the navigation panel click Status System Information to display the screen as shown below This page allow user to configure and browse some system information...

Страница 19: ...field displays the subnet mask of the switch Gateway This field displays the IP address of the gateway Loader Version This field displays the loader version of the switch Loader Date This field displ...

Страница 20: ...rity Select severity level s to filter log messages The possible severity levels are Error to record system failures such as events which will cause the switch to malfunction and events such as invali...

Страница 21: ...the criteria specified in the fields above No This is the index number for the log entry Severity This field displays the severity level of the log entry Category This field displays what category the...

Страница 22: ...this port Rx Good Pkt This field shows the number of frames successfully received on this port Rx Bad Pkt This field shows the number of frames unsuccessfully received on this port Clear Click the Cl...

Страница 23: ...Web Managed GbE Switch 23...

Страница 24: ...ort Error Disabled This page allow the user to browse ports that are disabled by some protocols such as BPDU Guard Loopback and UDLD The following table describes the labels on this screen LABEL DESCR...

Страница 25: ...riod This shows the period interval between last and next refresh You have three choices 2 sec 5 sec and 10 sec IFG You can enable or disable this function 3 1 4 Trunk Group Click Status Trunk Group i...

Страница 26: ...ally in most settings such as VLAN port ability and so on but follow the configuration of the master port Member This field shows the member ports of the trunk Active Passive If the trunk is an LACP t...

Страница 27: ...r dynamic MAC entries If not selecting any port VLAN or MAC address the whole dynamic MAC table will be displayed or cleared View Click the View button to display the logs according to the criteria sp...

Страница 28: ...x number for the MAC address forwarding entries Delete To delete any selected MAC address entries 3 2 Network Use the Network pages to configure settings for the switch network interface and how the s...

Страница 29: ...server that can assign the switch an IP address a subnet mask and a gateway IP address automatically IP Address Enter the IP address of your switch in dotted decimal notation for example 192 168 2 1 I...

Страница 30: ...ress in this field Gateway Enter the IP address of the gateway in dotted decimal notation If auto configuration mode is disabled enter the IPv6 gateway address in this field Apply Click Apply to save...

Страница 31: ...t Enable to use Simple Network Time Protocol SNTP or Disable to set the time manually SNTP Server Address If SNTP is enabled enter the IP address of the time server you will use SNTP Server Port It sh...

Страница 32: ...hown below The following table describes the labels in this screen LABEL DESCRIPTION Port Select Select the port s from the list box that you will change the port settings for Name It allows you to gi...

Страница 33: ...switch uses IEEE802 3x flow control in full duplex mode and backpressure flow control in half duplex mode IEEE802 3x flow control is used in full duplex mode to send a pause signal to the sending por...

Страница 34: ...etwork b Mirroring Port 1 RX means copy the incoming packets of the selected source port to the selected destination port 2 TX means copy the outgoing packets of the selected source port to the select...

Страница 35: ...t the LACP active ports to be added to the trunk group This field is active when LACP is selected as the Type Apply Click Apply to save your changes to the switch Trunk This field displays the trunk n...

Страница 36: ...on The following table describes the labels on this screen LABEL DESCRIPTION LACP Enable Select Enable from the drop down box to enable Link Aggregation Control Protocol LACP Select Disable to not use...

Страница 37: ...defined VLANs easier to identify and remember Untagged Ports Select Select Untagged to make the port a permanent member of this VLAN group All outgoing frames will be transmitted without a VLAN Group...

Страница 38: ...hat the tag defines The following table describes the labels on this screen LABEL DESCRIPTION Port Select Select the ports to change the PVID for PVID Enter a number between 1 and 4094 as the port VLA...

Страница 39: ...ss the screen below The following table describes the labels in this screen LABEL DESCRIPTION Port Select Select the ports you re changing the settings for Tag Mode Port tag mode Original Tag depends...

Страница 40: ...describes the labels on this screen LABEL DESCRIPTION State Select Enabled from the drop down box to enable VLAN Ingress Filter Select Disabled to not use VLAN Ingress Filter Apply Click Apply to sav...

Страница 41: ...cking tag protocol identifier 0x0000 0xFFFF Apply Click Apply to save your changes to the switch 3 3 5 2 SVLAN Member Setting This page allows the user to configure VLAN stacking members Click Switchi...

Страница 42: ...d or set port VLAN stacking entries in the VLAN stacking table Click Switching SVLAN SVLAN PVID Setting to access the screen below The following table describes the labels in this screen LABEL DESCRIP...

Страница 43: ...Select the port s to configure the settings for Enabled Set VLAN stacking aware state Enabled Set as VLAN stacking aware Disabled Set as VLAN stacking unaware Apply Click Apply to save your changes t...

Страница 44: ...preamble IFG 20 bytes when count ingress bandwidth rate Egress Preamble IFG Select the mode of egress preamble IFG Excluded exclude preamble IFG 20 bytes when count egress bandwidth rate Included inc...

Страница 45: ...Traffic that exceeds the maximum bandwidth allocated in cases where the network is congested is dropped Specify the bandwidth in kilobits per second kbps Enter a number between 0 and 1048544 The numb...

Страница 46: ...es to configure settings for the switch network interface and how the switch connects to a remote server to get services 3 3 7 1 IGMP Setting Click Switching IGMP Snooping IGMP Setting to access the s...

Страница 47: ...t query interval is 125 seconds Response Time The time a generic system or functional unit takes to react to a given input The default value is 10s Router Timeout Save the time of the router port time...

Страница 48: ...erier State Select Enable from the drop down box to enable IGMP Querier Election Select Disable to not use IGMP Querier Election Apply Click Apply to save your changes to the switch Querier Status It...

Страница 49: ...Table Click Switching IGMP Snooping Router Table to access the screen below The following table describes the labels on this screen LABEL DESCRIPTION VID The VLAN ID that has router port Port Router...

Страница 50: ...ytes from 0 to 9216 Apply Click Apply to save any changes to the switch 3 3 9 STP The Spanning Tree Protocol STP is a network protocol that ensures a loop free topology for any bridged Ethernet local...

Страница 51: ...the maximum number of hops in the region Enter a number between 1 and 40 as the max number of hops Forward Delay Set the delay time an interface takes to change from blocking state to forwarding state...

Страница 52: ...n periodic transmissions of BPDU by Designated Ports This is the time interval in seconds at which the root switch transmits a configuration message The root bridge determines Hello Time Max Age and F...

Страница 53: ...U Guard Set the BPDU Guard configuration No Disable BPDU Guard function Yes Enable BPDU Guard function To drop directly the received BPDU from the specified ports P2P MAC Set the Point to Point port c...

Страница 54: ...ick Apply to save your changes to the switch MSTI ID MSTI is MST Configuration ID Enter a number between 1 and 15 as the MSTI ID Action Type Select the action type Add VID Add the VLANs in the VLAN li...

Страница 55: ...fy MST instance Priority You can manually set the Bridge Priority in the specified MST instance Apply Click Apply to save your changes to the switch MSTI It displays the CIST s number Instance Status...

Страница 56: ...Path Cost You can manually set the internal path cost to the selected ports in the specified MST instance 0 means Auto Priority You can manually set the priority to the selected ports in the specifie...

Страница 57: ...will use storm control Storm Type Select the type of packets to be limited with the Storm Control feature Broadcast Broadcast packet Multicast All multicast packet including known and unknown multicas...

Страница 58: ...the switch Click Security MAC Filtering in the navigation panel to display the screen shown below The following table describes the labels on this screen LABEL DESCRIPTION MAC Address Type a MAC addre...

Страница 59: ...t will be filtered VLAN This is the VLAN group to which the MAC address belongs Filter This field displays the action of the filter Name This field displays the descriptive name for this rule This is...

Страница 60: ...nge this value unless your network administrator instructs you to do so Shared Key max 30 characters Specify a password up to 32 alphanumeric characters as the key to be shared between the external RA...

Страница 61: ...table describes the labels on this screen LABEL DESCRIPTION Port Specify the ports to activate IEEE 802 1x port authentication on Mode Select Force Unauthorized to always force this port to be unauth...

Страница 62: ...RSWLRQV Enable Enable port security function Disable Disable port security function Max L2 Entry Maximum number of Layer 2 entries that assign the MAC address to the port Apply Click Apply to save you...

Страница 63: ...ay the configuration screen as shown below The following table describes the labels on this screen LABEL DESCRIPTION Port List To select the port to be protected Port Type Configure port protect type...

Страница 64: ...out the CLI will log out automatically Enter a number between 0 and 1440 as the session timeout 0 minutes means never time out Apply Click Apply to save your changes to the Switch 3 4 6 2 Telnet Telne...

Страница 65: ...t minutes for user access of the CLI from a Telnet line If the user doesn t respond after the session timeout minutes the CLI will log out automatically Enter a number between 0 and 1440 as the sessio...

Страница 66: ...r changes to the Switch 3 4 6 4 HTTP HTTP is the acronym for Hyper Text Transfer Protocol The following table describes the labels on this screen LABEL DESCRIPTION Session Timeout Set session timeout...

Страница 67: ...the user doesn t respond after the designated session timeout minutes the Web UI will log out automatically Enter a number between 0 and 1440 as the session timeout 0 minutes means never time out Appl...

Страница 68: ...the index information Name It displays the name of the index Port List It displays the list of the port VLAN List It displays the list of the VLAN Policy Index It displays the policy index Modify Cli...

Страница 69: ...igure ACE Click ACL ACL Setting Add Add in ACE Setting button and the ACE Content Web page displays LABEL DESCRIPTION Comment Enter ACE comment in this field src mac Enter source MAC data and mask in...

Страница 70: ...reen LABEL DESCRIPTION Template Index You can choose the template index Get To get the basic information of the policy index src mac Click in the square box to set source MAC into Template dst mac Cli...

Страница 71: ...square box to set TCP flag into Template Apply Click Apply to save your changes to the switch 3 5 3 ACL Index Range Setting The following table describes the labels on this screen LABEL DESCRIPTION AC...

Страница 72: ...ation of the specified mirror index Rate Limit limit the packet rate 7he LQFUHPHQW is 16 kbps Priority change the packet priority Apply Click Apply to save your changes to the switch 3 6 QoS Use the Q...

Страница 73: ...based priority you want to assign to the packets coming into the switch on the ports specified in the port field Apply Click Apply to save your changes to the switch Port This field displays the port...

Страница 74: ...ports specified in the port field The priority range is 0 to 7 Apply Click Apply to save your changes to the switch 802 1 p This field displays the 802 1p priority level which you ve choosed Priority...

Страница 75: ...riority This field displays the DSCP classification identification number s IEEE 802 1p Priority 3 6 4 Priority to Queue Mapping Click QoS Priority to Queue Mapping to display the screen as shown next...

Страница 76: ...d for excellent effort or better than best effort and would include important business traffic that can tolerate some delay 4 Typically used for controlled load latency sensitive traffic such as SNA S...

Страница 77: ...hm Select the algorithm of packet scheduling WFQ WRR Note Weighted Fair Queuing is used to guarantee each queue s minimum bandwidth based on its bandwidth portion weight the number you configure in th...

Страница 78: ...for configuration it s weighted The Queue ID range is 1 to 8 Weight Configure the queue scheduling weight of specified ports Range is valid as following 0 means the queue is strict mode 1 127 means th...

Страница 79: ...riority Remarking Click Enabled to enable this function on specified ports Click Disabled to disable this function on specified ports DSCP Remarking Click Enabled to enable this function on specified...

Страница 80: ...1p Priority Remark to the new 802 1p priority that the priority and drop precedence mapped to The new 802 1p priority is 0 to 7 New DSCP Value Remark to the new DSCP priority that the priority and dro...

Страница 81: ...scribes the labels on this screen LABEL DESCRIPTION State SNMP daemon state Select Enabled to activate SNMP daemon Select Disabled to not use SNMP daemon 3 7 1 2 SNMP Community Click Management SNMP S...

Страница 82: ...s configure settings on the switch Add Click Add to add any other community No It displays the port number in the community Community This field displays the community strings Access Type This field d...

Страница 83: ...re sent Community Type This field displays the password sent with each trap to the SNMP manager Delete Click Delete to remove any selected trap receiver entries 3 8 Diagnostics Use the Diagnostics pag...

Страница 84: ...as the size The default configuration is 0 Ping Results After a ping is finished results will show in this field Apply Click Apply to save your changes to the switch 3 8 2 Ping6 Test The following ta...

Страница 85: ...owing table describes the labels on this screen LABEL DESCRIPTION Target Select the target to store log message RAM store the log messages on the RAM disk All log messages will disappear after a syste...

Страница 86: ...splays the status of local log settings Target It displays the target you ve chosen Severity It displays the severity status Action Click enable to enable this function Click disable to disable this f...

Страница 87: ...g debugging of the switch s function This field is not recommended for tracking as it creates many messages not helpful to typical users Notice to record errors that need attention Apply Click Apply t...

Страница 88: ...en shown below 2 Click the Reboot button and the following interface displays 3 When finished the switch will have been restarted 3 9 Maintenance 3 9 1 Backup Manager This page allows the user to back...

Страница 89: ...ed GbE Switch 89 Backup Config with TFTP Page Backup Image with HTTP Page Backup Config with HTTP Page The following table describes the labels on this screen LABEL DESCRIPTION Backup Select the backu...

Страница 90: ...figuration If the Configuration backup type is selected one of the configuration files in the current system can be selected for backup Backup Click Backup to save the current switch configuration to...

Страница 91: ...thod is selected the browse file field allows you to select any file on the host operating system Upgrade Type Select upgrade type Image Firmware image of current system Configuration Configuration fi...

Страница 92: ...to save running configurations to any file the user specified Set Startup Click Set startup to select any existing configuration file as the startup configuration File Name It displays the name of the...

Страница 93: ...field Privilege Type Select a privilege level for new account Admin Allow to make changes in switch settings User See switch settings only Do not allow changes Apply Click Apply to save your changes t...

Страница 94: ...ord type for the enable password function Clear Text Password without encryption Encrypted Password with encryption Password Enter your new system password Retype Password Retype the password to make...

Страница 95: ...Protocol General Media support 10Base T Cat3 4 5 UTP STP RJ45 100Base TX Cat5 UTP STP RJ45 1000Base T Cat5e UTP STP RJ45 Packet filter forwarding rate 1 488 000 pps 1000 Mbps 148 800 pps 100 Mbps 14...

Страница 96: ...ment Protocol LAN settings IP address gateway etc Certifications FCC Class A CE LEDs Power Link activity Power Input 100 240 V AC 50 60 Hz Power consumption 30 watts maximum Environmental Metal housin...

Отзывы: