iN199 Air Intake Inlet and Exhaust Gas Outlet Pipe Connections 22
November 2021 - Revision 00
7.3.4 Roof Air Intake Inlet and Exhaust Gas Outlet
Pipe Termination
With this installation method, the terminations must extend
at least 12 inches over maximum potential snow levels, or as
required by local building codes. In areas of high snow fall,
protect the vent terminations from blockage.
Terminate the air intake inlet pipe with a 90° elbow (angled
down). A suitable roof flashing and vent cap (not supplied)
should be installed.
12" USA or
18" Canada
over maximum
snow level or
as required by
local code
12" Minimum
3' Minimum
12" USA or
18" Canada
over maximum
snow level or as
required by local
code
Exhaust
Intake Air
Single unit.
Intake Air
Exhaust
See
Note
Multiple units.
Note:
The distance between any exhaust gas outlet and air
intake inlet pipe should be between 18 and 36 inches
apart. If this minimum specification cannot be met,
the air intake inlet and exhaust gas outlet pipes should
be 72 inches apart or more.
7.4 Single Pipe Venting System
7.4.1 Single Unit
The following illustrations represent some typical venting
configurations and are included to assist in designing the
vent system. Possible configurations are not limited to these
designs.
Intake
Air
Intake
Air
Intake
Air
Intake
Air
Intake
Air
Intake
Air
Intake
Air
Exhaust
Exhaust
Exhaust
Exhaust