1-8
Microstepping MForce PowerDrive Manual Revision R040507
Mechanical Specifications -
Dimensions in Inches (mm)
Figure 1.2.1: MForce PowerDrive Mechanical Specifications
Microstepping MForce PowerDrive Setup Parameters
Name
Function
Range
Units
Default
MHC
Motor Hold Current
0 to 100
percent
5
MRC
Motor Run Current
1 to 100
percent
25
MSEL
Microstep Resolution
1, 2, 4, 5, 8, 10, 16, 25, 32, 50,
64, 100,108, 125, 127,128,
180, 200, 250, 256
µsteps per
full step
256
DIR
Motor Direction Override
0/1
–
CW
HCDT
Hold Current Delay Time
0 or 2-65535
mSec
500
CLK TYPE
Clock Type
Step/Dir. Quadrature, Up/Down
–
Step/Dir
CLK IOF
Clock and Direction Filter
50 nS to 12.9 µS
(10 MHz to 38.8kHz)
nS (MHz)
200nS(2.5
MHz)
USER ID
User ID
Customizable
1-3 characters
IMS
WARN TEMP
Warning Temperature
0 to +125
ºC
80
EN ACT
Enable Active High/Low
High or Low
—
High
Table 1.2.6: Setup Parameters
Setup Parameters
The following table illustrates the setup parameters. These are easily configured using the IMS SPI Motor Interface
configuration utility. An optional Parameter Setup Cable is available and recommended with the first order.
3.473
(88.21)
2X 0.580
(2X 14.73)
Ø 0.187 ±0.01
(Ø 4.75 ±0.25)
2X #8 Screws
for End Mount
3.00 ±0.01
(76.2 ±0.25)
2.116
(53.75)
0.225
(5.72)
P4
P3
P1
3.473
(88.21)
Ø 0.160 ±0.01 Thru
(Ø 4.06 ±0.25 Thru)
4X #6 Screws
for Flat Mount
0.308 TYP.
(7.82 TYP.)
2.931 TYP.
(74.45 TYP.)
3.897
(98.98)
0.417 TYP.
(10.59 TYP.)
0.160 ±0.01
(4.06 ±0.25)
2.950
(74.93)
Содержание MForce PowerDrive Plus MForce Series Microstepping PowerDrive
Страница 1: ...Operating Instructions TM Excellence in Motion TM FORCE POWER DRIVE MICROSTEPPING...
Страница 10: ...1 4 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Страница 18: ...1 12 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Страница 20: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Страница 24: ...Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...
Страница 36: ...18 Microstepping MForce PowerDrive Manual Revision R040507...
Страница 60: ...A 2 Microstepping MForce PowerDrive Manual Revision R040507 Page Intentionally Left Blank...