Intelligent Home DT-AKP - инновационное устройство для автоматизации дома. Подробное руководство по использованию доступно для бесплатного скачивания на {сайт}. Обеспечьте себе простоту управления вашим домом с помощью этого умного устройства.
User Manual
RF CARD
DT-ENG-AKP-V1 / 201701
• Please read this manual carefully to ensure safe and correct operation.
• Keep this manual well for future reference.
DT-AKP
2 WIRE SYSTEM
Access keypad panel with scramble keypad
Страница 1: ...ual RF CARD DT ENG AKP V1 201701 Please read this manual carefully to ensure safe and correct operation Keep this manual well for future reference DT AKP 2 WIRE SYSTEM Access keypad panel with scrambl...
Страница 2: ...ad 3 LED1 indicator 4 LED2 indicator 5 LED3 indicator 6 ID card window 7 Mounting hook 8 Connection port 9 Screw hole SD Card Slot To insert micro SD card BUS Connect to the bus line non polarity 12V...
Страница 3: ...ect the cable correctly 4 Electric Lock Connection 4 1 Internal Power Supply Mode Use the power of the system to supply for the electronic lock so that the lock can be connected to the access keypad p...
Страница 4: ...wer on to Unlock type 12V 300mA 12V LK GND LK COM N O EB EB Set Unlock Relay mode to Normally Closed 1 B Connection for Power off to Unlock type 4 2 External Power Supply Mode When the electronic lock...
Страница 5: ...o continue the setting operation Press to exit the setting mode The example is set as cancel button and as confirm button please refer to function setting for detail information Forbid sliding touch t...
Страница 6: ...12 Unlock work mode 11 Valid keys 0 3 0 13 Backup master user card password tone 12 1 2 3 4 14 Update master user card password tone 13 1 2 3 4 15 Device Address 14 Valid keys 0 3 0 16 RLC Control 15...
Страница 7: ...elete user card Double flash Format or Configuration switching of DT ACC and ID card it waits for confirmation LED3 Light on Setting code Flash Setting value Digitron display Prompt OP1 Release the fi...
Страница 8: ...application ID The access control is configured for the ID card unlock application S A Register Add Manage card S D Register Delete Manage card ADD Add user card DEL Delete user card CLE Format user...
Страница 9: ...ut the setting code Inputting of code Input the setting code 1 Reset all settings 00 1234 4321 01 0 09 Input the setting code 02 Input the setting code 03 Digitron display mode 0 The scrolling display...
Страница 10: ...the item is set to 1 press the button to cancel the input and press the button to confirm the input on off off LED1 LED2 LED3 Beep Beep flash off off LED1 LED2 LED3 Beep Beep flash off off LED1 LED2...
Страница 11: ...setting code 11 Inputting of value ex 0 range 0 3 0 Default 0 0 Unlock via password or user card only release the first lock 1 Unlock via password or user card swipe user card once time to release th...
Страница 12: ...address auto correlation 1 Association of the first RLC 2 Association of the second RLC 3 Association of the third RLC 4 Association of the fourth RLC Beep Beep on off off LED1 LED2 LED3 Beep Beep fl...
Страница 13: ...re will be cleared at the same time The temporary code can not be set the same as the master code and user code The user code group1 is used to release the first lock and the user code group2 is used...
Страница 14: ...nd then swipe user cards one by one to be deleted Beep Beep on off off LED1 LED2 LED3 Beep Beep flash off off LED1 LED2 LED3 Beep Beep flash off off LED1 LED2 LED3 Beep off on off LED1 LED2 LED3 Beep...
Страница 15: ...one Select item is set to 1 then the electric door strike is unlocked The time interval between 2 digitals input must be less than approximately 10 seconds otherwise the input value will be cleared If...
Страница 16: ...n access control keypad directly Excessive moisture may cause problems with the unit You must use the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to...