-12-
The farest monitor
B
A
C
DBC4A1
monitor
monitor
monitor
with two or four monitors
100~240VAC
BUS(IM) BUS(DS)
PC6A
AC~
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the
maximum distance which the system can reach.
When Monitor quantity < 20
Cable Usage
A
B
C
Twisted cable 2x0.75 mm
2
60
60
30
Twisted cable 2x1 mm
2
80
80
40
When Monitor quantity > 20
Cable Usage
A
B
C
Twisted cable 2x1 mm
2
70
30
20
Twisted cable 2x1.5 mm
2
70
50
30
Note:If the monitor has been specified the distance,refer to the
parameter.
11. Cables Requirements