MB/TS25 PC211 UPGRADE Battery Charger
Operators Manual
4.6.3 CALIBRATION PARAMETERS
After unit servicing where the battery-backed memory has been reset the
calibration parameters may become corrupt and need resetting to enable the unit
to operate correctly so that a correct calibration can be performed. The default
calibration values are correct at time of manufacture, but in time as components
deteriorate re-calibration will be necessary to keep output to specified tolerances.
4.6.4 SELECTING RESET MODE
To perform this function both channels must be STOPPED. Press
EXTD
twice
rapidly. The display will flash three numeric digits. These correspond to the
firmware release of the unit. By pressing the
and
arrow keys the display can
be changed to show
PRS
,
LRS
or
CRS
. Once selection is made on the display the
ENTR
key must be pressed to invoke the operation. If the operation needs to be
cancelled i.e. if confirmation of firmware revision number is all that was needed
then hitting the STOP key will abort the reset mode.
PRS
Parameter Reset.
LRS
Library Reset
CRS
Calibration Reset
Doc: DWG1006-34-R3 TS25 PC211 Upgrade Operators manual.odtPage 21 of 44