LSU220A : Load Support Unit
Operators Manual
CURRENT MEASUREMENT
5.1
CHECKING PROCEDURE
5.1.1
Voltage validation
With no load connected to the LU220A switch on and press the START push
button.
Using the OUTPUT TRIM
pq
push buttons set the output voltage to 24.0V.
Note if you press and hold either the
pq
push buttons the adjustment
will be continuous.
With the calibrated voltmeter connected to the output terminals verify that
the voltage reading is 24.0V +/- 0.2V
If the voltage is outside of tolerance follow the ADUSTMENT PROCEDURE
Doc: DWG1063-08-R2 LSU220A Operators Manual.odt
Page 11 of 16
Copyright Material of Intelligent Charging Limited © 2018
Printed On : 17/07/19