135
REMOTE WEB ACCESS
Network Setting
1
3
4
2
No.
Item
Description
1
Network Setting
Modify ACU's Internal IP address.
2
Ethernet Port
Configuration
Modify ACU’s Internal IP address and press Submit button. Go
to “Save & Reboot” page and press Save & Reboot button to
validate the changes.
- IP Address: Factory default
(Primary: 192.168.0.223) / (Secondary: 10.10.1.1)
- Subnet Mask: Factory default (255.255.255.0)
- Gateway (router IP): Factory default (192.168.0.254)
3
Management Port
Configuration
Modify Management Port’s network configuration and press
Submit button. Go to “Save & Reboot” page and press Save &
Reboot button to validate the changes.
- Management Port: Set disable on Management Port
connection if IP address conflicts across the network when
Ethernet port and Management port are both in use. Factory
default is set to Enable.
- DHCP Server: Set whether or not to use DHCP Server.
Enabling DHCP Server allows access to Web M&C page
without configuration of network address on a PC. To use
the DHCP service, the PC should be also set to use DHCP.
- IP Address: Factory default (192.168.2.1)
- Subnet Mask: Factory default (255.255.255.0)
- Lease Start Address: Set Lease Start Address when DHCP
Server is enabled. Factory default (192.168.2.2)
- Lease End Address: Set Lease End Address when DHCP
Server is enabled. Factory default (192.168.2.30)
- Lease Time: Factory default is 180 min
4
Network Service
Configuration
Select to enable or disable Telnet Service.
5
Browser
Configuration
Modify browser refresh rate and refresh disable time. If the check
box of Refresh Disable Time is enabled, then Refresh Disable
Time function will be activated and system will keep monitoring
all activities regardless of time-out.