63
OPERATING THE ACU
Detect & tracking level
Set detect & tracking NBD
BOW & EL adjust
D E T E C T N B D
T R A C K I N G N B D
0 4 0
0 2 0
6. Set DETECT NBD and TRACKING NBD when NBD (Narrow Band Detection) mode of
TRACKING SIGNAL is chosen to be used (Range: 1-200).
DETECT NBD is to set the satellite signal detection level and TRACKING NBD is to set the
satellite signal tracking level.
Touch LEFT and RIGHT arrow keys until the desired character is underscored (selected).
Touch UP and DOWN arrow keys to increase and decrease the selected character.
Touch OK key to set the parameter. Touch BACK key to select the parameter you wish to edit
and touch BACK key again to save or abort and return to the main display.
Noise Level
Detect Level
Tracking Level
TRACKING DVB/NDB
Peak Level
DETECT DVB/NDB
B O W O F F S E T E L . A D J U S T
0 0 0
+ 0 . 0
7. Set BOW OFFSET and EL. ADJUST
BOW OFFSET is to offset the angle difference between the antenna’s bow and the ship’s bow
(Range: 0 – 360°) and EL. ADJUST is to offset the angle difference between the mechanical
elevation angle and actual elevation angle (Range: ± 5°).
Touch LEFT and RIGHT arrow keys until the desired character is underscored (selected).
Touch UP and DOWN arrow keys to increase and decrease the selected character.
Touch OK key to set the parameter. Touch BACK key to select the parameter you wish to edit
and touch the BACK key again to save or abort and return to the main display.
Содержание GX100PM
Страница 1: ...Marine Satellite Communication Antenna System GX100PM Installation and Operation Manual...
Страница 2: ......
Страница 4: ...INDEX...
Страница 10: ......
Страница 11: ...11 INTRODUCTION Intellian GX100PM Introduction Intellian GX100PM Features System Configuration INTRODUCTION...
Страница 80: ...GX100PM Marine Satellite Communication System 80...
Страница 110: ...GX100PM Marine Satellite Communication System 110...