GX100PM – Marine Satellite Communication System
40
PC to BDT Communication Setup
You can establish data communication between a PC and the BDT using one
of the following methods.
TCP/IP Connection
Connection through Front Panel Management Port
To connect the BDT to the PC through the Management Ethernet Port on the front
BDT panel, the network should be configured by setting up the PC IP before the
connection. This method requires separate IP configuration on a PC.
1.
Connect an Ethernet cable from a PC Ethernet port to the Management
---------
Port on the front of the BDT.
2.
Go to Control Panel > Network and Sharing Center > Change Adapter
---------
Settings. Right-click on the Local Area Connection and click Properties.
3.
Select TCP/ IPv4, and click Properties.
4.
Change the network settings on a PC;
- Default IP: 192.168.1.5
- Subnet Mask: 255.255.255.0
- Gateway: 192.168.1.1
5.
Use the following IP address to access Intellian Aptus
®
or Aptus Web
-----
--------
page.
- Default IP: 192.168.1.2
PC
Management
ethernet port
Содержание GX100PM
Страница 1: ...Marine Satellite Communication Antenna System GX100PM Installation and Operation Manual...
Страница 2: ......
Страница 4: ...INDEX...
Страница 10: ......
Страница 11: ...11 INTRODUCTION Intellian GX100PM Introduction Intellian GX100PM Features System Configuration INTRODUCTION...
Страница 80: ...GX100PM Marine Satellite Communication System 80...
Страница 110: ...GX100PM Marine Satellite Communication System 110...