CMR-6100 User Manual 

 
 
 

 

 
 
 
 
 
 
 
 
 
 

Doc ID: TS-34-0512 

Published May 29, 2012 

 
 

 
 

Содержание CMR-6100

Страница 1: ...CMR 6100 User Manual Doc ID TS 34 0512 Published May 29 2012...

Страница 2: ...This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference...

Страница 3: ...Interface 9 3 1 Establishing a Connection 9 3 2 Checking Versions and Status 9 3 3 Manually Setting to Static or DHCP 10 3 4 Upgrading Reader Firmware 11 3 5 Basic Inventory Demo 11 3 6 Basic Memory R...

Страница 4: ...communicating to the CMR 6100 and other local devices The CMR 6100 also offers two optically isolated general purpose inputs and two open drain outputs There are two pairs of bi static antenna connec...

Страница 5: ...O 18000 6C revision 1 Manchester BAP 25 6 25 sec 8 128 Kbps BLF 80 320 KHz M 2 128 2 5 160 Kbps Performance Transmitter RF Output Power Receiver Sensitivity Frequency Range Number of Channels 0 to 30...

Страница 6: ...TNC connecters Figure 2 3 1 Tx and Rx antenna spacing Two pairs of antenna pairs may be connected to the reader at any given time When several Rx and Tx antennas are connected the reader can be set up...

Страница 7: ...rom the reader The light will flicker or pulse at a rate that is dependent on the length and duty cycle of the transmission If the reader is assigned to read the full content of user memory the light...

Страница 8: ...IO socket that the provided screw terminal fits into The screw header fits securely into the socket and is tightened down with the two attached screws Looking at the reader the pins are numbered left...

Страница 9: ...n inventory C3 or C1G2 tag IDs and interact with tag memory 3 1 Establishing a Connection The CMR 6100 reader supports Internet Explorer and Mozilla Firefox For More information about obtaining the IP...

Страница 10: ...in Management tags the Reader Name Network Setup and NTP server can be dynamically configured Be sure to talk to your network administrator before assigning a static IP address to the reader as this c...

Страница 11: ...rent RF and reader parameters read and write to tag user memory and verify functionality of the system Figure 3 5 1 Inventory and Search Configuration Page Reader parameters are controlled via config...

Страница 12: ...the left shows the tag ID of each tag as it is read Text from this window may be copied into a document if needed The window holds the last 100 tag IDs read The summary window on the right displays th...

Страница 13: ...in the same way that the EPC memory was accessed here 3 7 GPIO Testing and Verification Page The GPIO Testing page enables the CMR 6100 to either set or detect the logic levels of the general purpose...

Страница 14: ...rmat Plug and play architecture allows for easy addition of new message formats see Intelleflex Data Services documentation for more details about message formats Data Buffering If there is no connect...

Страница 15: ...User Manual CMR 6100 15 Intelleflex Confidential...

Страница 16: ...reader set the following parameters protocol C3 or C1G2 power set full power at 30 dBm Q value set between 4 and 6 select the right Tx and Rx antennas Make sure that the appropriate type of tags are...

Страница 17: ...through our web submittal form http www intelleflex com Support sfdcform asp or E mail support intelleflex com If the reader needs to be returned for service please fill out the warranty card include...

Страница 18: ...the System Properties window click on the Hardware tab 5 With the Hardware tab selected click on the Device Manager Button For Windows 7 1 Click on Start and then type Device Manager in the search bar...

Страница 19: ...ommand Space and type in Terminal Once you have a terminal window open type the following Linux commands Note that they might be slightly different based upon which version of Linux that is running Fi...