Intelimax LITE User Manual
V1.02
- 36 -
M O D E M D E B U G G I N G
Local Connection Checking
In order to verify that the modem is operating correctly locally, follow the below steps:
1.
Check that modem Power LED is either solid on or mostly on. The better the
signal strength the more time the Power LED will stay on.
2.
In Serial Modem mode:
a.
Connect to modem with GUI via RS232 interface and check the
registration and signal strength of the modem. The status page will show
whether the modem is currently registered as well as showing the signal
level in dBm, which should be better than -93dBm.
b.
Trigger a connection through the modem (either CSD or PPP
connection) and ensure that the data light will correctly blinking to
indicate data transfer through modem.
3.
In IP Stack Auto mode:
a.
Connect to modem with GUI via RS232 interface and check the
registration and signal strength of the modem. The status page will show
whether the modem is currently registered as well as showing the signal
level in dBm, good levels are better than -81 dBm.
b.
Ensure that the modem has a data connection which should be
automatically set up by the modem. If the data LED is blinking then this
connection has been established.
4.
In both modes:
a.
Connect to the modem using the USB interface and install the EHS6
module drivers if required.
b.
Open Windows device manager, check which COM port is matched to
EHSx USB3 and open a terminal connection to the COM port.
c.
Once connected you can check the following via AT commands:
i.
AT+CSQ to check signal strength is better than -81 dBm
ii.
AT+CREG to check that the modem is registered, the response
should be +CREG: 0,1.