background image

www.intelco.com.gr 

INTD1001 

Metal Keypad for access control 

INTD1001 Key

lock

 

Please read the instructions carefully in order to get 

all of the benefits of this device. 

 

Page 2     

General description 

 

Page 3         Features - Specifications 

 

Page 4   

Wiring 

 

Page 5    

Operation 

 

Page 6-7 

Programming  

 

Page  8   

Buzzer Sounds  

Reference Manual 

Rev. 1.00  January 2015

 

Содержание INTD1001/1

Страница 1: ...Keylock Please read the instructions carefully in order to get all of the benefits of this device Page 2 General description Page 3 Features Specifications Page 4 Wiring Page 5 Operation Page 6 7 Pro...

Страница 2: ...ight Relay commands INTD1001 S With one Relay and serial communication with extension device INTD1001 E8 Extension device 8 Relays with serial communications General Description Dear customer Thank yo...

Страница 3: ...delay for each relay Latch mode supported for each relay False password Detect and Lock function Features Power supply 12 to 24 V DC AC Power consumption 0 3mA with 8 relay enabled Security Levels Us...

Страница 4: ...s from relays to control panel and then power on see Schematic 1 After Keylock is properly powered you will here a short sound 500ms and then device is ready to use Wiring Connection Power Supply CAUT...

Страница 5: ...e pressed key 1 8 will release the relay too Act as Password Protected Relay After programming and enable one of Relay 1 8 working as Password Protected Relay then any action referred to this Key it w...

Страница 6: ...ill be enabled Enable Password While desired relay password is disabled set 000 as User Old password Factory preset password and set any desired password at User New password Ex 653 Note Factory prese...

Страница 7: ...ssword Relay Programming Latch Mode Programming latch mode requires selected relay being in Password Protected Relay function Every Password Protected Relay act in 2 ways Latch Off Timer Latch On Latc...

Страница 8: ...Time is 2 seconds 02 99 877 Latch On code Relay Current User password of Relay Buzzer Sounds Buzzer helps the human interacts with the device in order to understand the process has been made in every...

Страница 9: ...strator Password While device is powered up administrator can handle is password according the below way Note Factory preset Admin password is 0000 0000 3546 Admin Old password Admin New password Rese...

Страница 10: ...entification of the owner in an algorithm that will generate Supervisor Password Programming Supervisor Password While device is powered up Supervisor password must be typed according the below way Af...