9
6. Operation
When energizing the sensor, it runs in test mode for 15 minutes so that all sensor positioning adjustments can be made.
During this period, at any motion detection the LED lights up and a trigger is generated.
After the test mode, the sensor goes into economic operating mode, so that when it detects movement it turns on the
LED, triggers and goes into hibernation, remaining for a period that can last from 30 seconds (environment with little
movement) up to 2 minutes (environment with a lot of movement). During this sleep period the LED is not activated and
no new triggers are generated, as a notification has just been sent to the control panel.
After the sleep time, the sensor goes back to monitoring the environment until detecting a new movement.
This ability to learn from the movement of the environment means that periodic and non-continuous shots are generated
in places with high movement, in turn, saving battery.
Trial
period
15 min
Period of
stabilization
Time the sensor remains on
Economic mode
30 seg - 2 min
After inserting
the battery, the
LED is blinking
and there is no
detection.
At any detection
the LED lights
up and
generates a
trigger.
After detecting the first
movement, the sensor turns on
the LED, triggers and enters the
sleep period.
During this period the
LED does not light and
no new triggers are
generated.
After the
hibernation time,
the sensor returns
to detect and
generate triggers
in the central,
starting the cycle
again.
7. Test
Once installed and energized, walk in the area to be protected simulating a possible intrusion. Observe if the sensor is
able to detect your movements during the journey, by lighting the lens. Adjust its sensitivity if necessary or reposition the
sensor installation.
Содержание IVP 1000 PET
Страница 1: ...User manual IVP 1000 Pet SF...