Intelbras IVP 1000 PET Скачать руководство пользователя страница 7

7

3. Product

1

7

3

4

6

5

2

8

1. Cabinet;
2. Fresnel lens;
3. 

PROG button;

4. Sensitivity selector switch;
5. red LED;
6. Pyro sensor;
7. Battery;
8. Antenna. 

4. Installation

The sensor must be installed on a flat, fixed, flicker-free surface with a height between 2.0 and 2.4 meters. It is recommen-
ded to install the sensor parallel to the wall for the greatest detection range. If the sensor is installed tilted or with the use 
of an articulator, its detection range and

 Pet function may be impaired in order to nullify the function.

To install the sensor, follow the procedure below:

 

» Open the sensor front cover using a screwdriver or similar tool.

 

» Insert the battery observing the polarity indicated on the product plate. The LED will blink for a few seconds (stabilization 

time), when it goes off, the sensor will already be in normal operation.

Note: 

do not register the sensor in the central during the stabilization time, wait for it to start working.

 

» To register the sensor code in the alarm control panel, check the procedure in the manual of the used alarm control panel 

and trigger a trip or press the

 PROG button located on the sensor board.

Содержание IVP 1000 PET

Страница 1: ...User manual IVP 1000 Pet SF...

Страница 2: ...nsor Congratulations you have just purchased a product with Intelbras quality and safety The IVP 1000 Pet SF motion sensor features passive infrared ray detection technology with advanced signal analy...

Страница 3: ...s or any object that blocks the scan Wireless communication technology when exposed to environments with high power radiation can suffer interference and have its performance impaired Example location...

Страница 4: ...Scan top view 0 2 4 6 8 8 6 6 4 4 2 2 0 10 12 m 8 m 90 Detection range side view 2 2 40 metros 1 2 4 6 8 10 12 m zone zero...

Страница 5: ...Technical specifications 6 2 Characteristics 6 3 Product 7 4 Installation 7 5 Sensitivity setting 8 6 Operation 9 7 Test 9 8 Low battery sensor 10 9 Battery replacement 10 10 Homologation 10 Warranty...

Страница 6: ...Transmission distance Up to 100m without barriers Modulation OOK Installation height range 2 0 to 2 4 meters Recommended installation height 2 1 meters Dimensions W H P 50 75 42 mm Weight 0 047 kg 2...

Страница 7: ...tion may be impaired in order to nullify the function To install the sensor follow the procedure below Open the sensor front cover using a screwdriver or similar tool Insert the battery observing the...

Страница 8: ...00 Pet SF was designed for indoor and closed areas and with the presence of animals of up to 20 kg so do not use it for protection of outdoor or open areas and with the presence of animals of more tha...

Страница 9: ...ability to learn from the movement of the environment means that periodic and non continuous shots are generated in places with high movement in turn saving battery Trial period 15 min Period of stabi...

Страница 10: ...1 to 2 years which may be influenced by the number of activations weather conditions and mode of settings The battery model must be CR123A 3V using one 1 battery per sensor 9 Battery replacement To r...

Страница 11: ...parties foreign to the manufacturer b if the damage to the product arises from accidents disasters agents of nature lightning floods landslides etc humidity voltage in the electrical network excess v...

Страница 12: ...via e mail suporte intelbras com br Customer Service 0800 7042767 Where to buy Who installs it 0800 7245115 Produced by Intelbras S A Ind stria de Telecomunica o Eletr nica Brasileira Rodovia BR 459 k...

Отзывы: