Mechanical Drawings
Intel
®
Xeon
®
Processor C5500/C3500 Series and LGA1366 Socket
Thermal/Mechanical Design Guide
August 2010
73
Order Number: 323107-002US
Figure B-1. Board Keepin / Keepout Zones (Sheet 1 of 4)
1
3
4
5
6
7
8
B
C
D
A
1
2
3
4
5
6
7
8
B
C
D
A
2200 MISSION COLLEGE BLVD.
P.O. BOX 58119
SANTA CLARA, CA 95052-8119
R
49.90
[
1.965
]
SOCKET BODY OUTLINE,
FOR REFERENCE ONLY
44.70
[
1.760
]
CENTERLINE OF OUTER
SOCKET BALL ARRAY
47.50
[
1.870
]
SOCKET BODY OUTLINE,
FOR REFERENCE ONLY
41.66
[
1.640
]
CENTERLINE OF OUTER
SOCKET BALL ARRAY
36.00
[
1.417
]
SOCKET ILM
HOLE PATTERN
90.00
[
3.543
]
MAX THERMAL
RETENTION OUTLINE
90.00
[
3.543
]
MAX THERMAL
RETENTION OUTLINE
61.20
[
2.409
]
SOCKET ILM
HOLE PATTERN
80.00
[
3.150
]
THERMAL RETENTION
HOLE PATTERN
80.00
[
3.150
]
THERMAL RETENTION
HOLE PATTERN
D77712
10
2
DWG. NO
SHT.
REV
SHEET 1
OF
4
DO NOT SCALE DRAWING
SCALE: 3.000
02
D77712
D
REV
DRAWING NUMBER
SIZE
THURLEY &
GAINESTOWN
ENABLING KEEPIN / KEEPOUT
TITLE
EASD / PTMI
DEPARTMENT
FINISH
MATERIAL
DATE
APPROVED BY
-
-
11/03/06
J. WILLIAMS
DATE
CHECKED BY
09/28/06
N. ULEN
DATE
DRAWN BY
09/28/06
N. ULEN
DATE
DESIGNED BY
UNLESS OTHERWISE SPECIFIED INTERPRET DIMENSIONS AND TOLERANCES IN ACCORDANCE WITH ASME Y14.5-1994 DIMENSIONS ARE IN MILLIMETERS TOLERANCES: .X
#
0.0 Angles
#
0.0
.XX
#
0.00
.XXX
#
0.000
THIRD ANGLE PROJECTION
THIS DRAWING CONTAINS INTEL CORPORAT
ION CONFIDENTIAL INFORMATION. IT IS
DISCLOSED IN CONFIDENCE AND ITS CONT
ENTS
MAY NOT BE DISCLOSED, REPRODUCED, DI
SPLAYED OR MODIFIED, WITHOUT THE PRI
OR WRITTEN CONSENT OF INTEL CORPORAT
ION.
AS VIEWED FROM PRIMARY SIDE
OF THE MOTHERBOARD
NOTES:
1. THIS DRAWING TO BE USED IN CORELATION WITH SUPPLIED
3D DATA BASE FILE. ALL DIMENSIONS AND TOLERANCES
ON THIS DRAWING TAKE PRECEDENCE OVER SUPPLIED FILE.
2. PRIMARY DIMENSIONS STATED IN MILLIMETERS. [BRACKATED]
DIMENSIONS STATED IN INCHES
3. SOCKET KEEP OUT DIMENSIONS SHOWN FOR REFERNCE ONLY
PLEASE REFER TO THE SOCKET B KEEPOUT / KEEPIN DRAWING
FOR EXACT DIMENSIONS
4
BALL 1 LOCATION WITH RESPECT TO SOCKET BALL ARRAY IS
FORMED BY INTERSECTION OF ROW A
& COLUMN 1. MAXIMUM
OUTLINE OF SOCKET SOLDERBALL ARRAY MUST BE PLACED
SYMMETRIC TO THE ILM HOLE PATTERN (INNER PATTERN) FOR
PROPER ILM
& SOCKET FUNCTION.
5. A HEIGHT RESTRICTION ZONE IS DEFINED AS ONE WHERE
ALL COMPONENTS PLACED ON THE SURFACE OF THE MOTHERBOARD
MUST HAVE A MAXIMUM HEIGHT NO GREATER THAN THE HEIGHT
DEFINED BY THAT ZONE.
ALL ZONES DEFINED WITHIN THE 90 X 90 MM
OUTLINE REPRESENT SPACE THAT RESIDES BENEATH THE HEAT
SINK FOOTPRINT.
UNLESS OTHERWISE NOTED ALL VIEW DIMENSION ARE NOMINAL.
ALL HEIGHT RESTRICTIONS ARE MAXIMUMS. NEITHER ARE
DRIVEN BY IMPLIED TOLERANCES.
A HEIGHT RESTRICTION OF 0.0 MM REPRESENTS
THE TOP (OR BOTTOM) SURFACE OF THE MOTHERBOARD AS
THE MAXIMUM HEIGHT.
SEE NOTE
7
FOR ADDITIONAL DETAILS.
6. SEE SHEET 4 FOR REVISION HISTORY.
7
COMBINED COMPONENT AND SOLDER PASTE HEIGHT INCLUDING
TOLERANCES AFTER REFLOW.
BALL 1 POSITION
4
LINE REPRESENTS
OF
OUTERMOST ROWS AND COLUMNS
OF SOCKET BALL ARRAY OUTLINE.
FOR REFERENCE ONLY
SOCKET BODY OUTLINE
FOR REFERENCE ONLY
LEGEND, THIS SHEET ONLY
ZONE 1:
0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT,
SOCKET, ILM, AND FINGER ACCESS KEEPIN ZONE
ZONE 2:
7.0 MM MAX COMPONENT HEIGHT
7
ZONE 3:
3.0 MM MAX COMPONENT HEIGHT
7
ZONE 4:
0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT
RETENTION MODULE OR HEAT SINK TOUCH ZONE
ZONE 5:
0.0 MM MAX COMPONENT HEIGHT, NO COMPONENT PLACEMENT,
NO ROUTE ZONE
ZONE 6:
1.97 MM MAX COMPONENT HEIGHT, SOCKET CAVITY
7