UPI-C42/UPI-L42
AC CHARACTERISTICSÐPROGRAMMING (UPI-C42 AND UPI-L42)
T
A
e
25
§
C
g
5
§
C, V
CC
e
6.25V
g
0.25V, V
DDL
e a
5V
g
0.25V, V
DDH
e
12.75V
g
0.25V
(87C42/87L42 ONLY)
Symbol
Parameter
Min
Max
Units
t
AW
Address Setup Time to RESET
u
4t
CY
t
WA
Address Hold Time after RESET
u
4t
CY
t
DW
Data in Setup Time to PROG
v
4t
CY
t
WD
Data in Hold Time after PROG
u
4t
CY
t
PW
Initial Program Pulse Width
95
105
m
s
t
TW
Test 0 Setup Time for Program Mode
4t
CY
t
WT
Test 0 Hold Time after Program Mode
4t
CY
t
DO
Test 0 to Data Out Delay
4t
CY
t
WW
RESET Pulse Width to Latch Address
4t
CY
t
r
, t
f
PROG Rise and Fall Times
0.5
100
m
s
t
CY
CPU Operation Cycle Time
2.5
3.75
m
s
t
RE
RESET Setup Time before EA
u
4t
CY
t
OPW
Overprogram Pulse Width
2.85
78.75
ms
(1)
t
DE
EA High to V
DD
High
1t
CY
NOTES:
1. This variation is a function of the iteration counter value, X.
2. If TEST 0 is high, t
DO
can be triggered by RESET
u
.
AC TESTING INPUT/OUTPUT WAVEFORM
INPUT/OUTPUT
290414 – 16
AC TESTING LOAD CIRCUIT
290414 – 17
19