![Intel True Scale Fabric Switches 12200 Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/intel/true-scale-fabric-switches-12200/true-scale-fabric-switches-12200_installation-manual_2073478053.webp)
True Scale Fabric Switches 12000 Series Hardware
July 2015
Installation Guide
Order Number: G91928004US
53
12000 Series Switches
setDefaultRoute -h <ipaddress>
where
-h <ipaddress>
is the new default gateway IP address in dotted decimal
format.
6. The changes are effective immediately.
2.9.4
Updating the Management Module IP Addresses in a Redundant
Management Configuration (12800-040, 12800-120, 12800-180
and 12800-360)
Each management module must have a unique IP address that is different than the
chassis IP address of the switch. A redundantly-managed switch will have multiple,
unique IP addresses.The default IP addresses are:
12800-040
:
• Chassis: 192.168.100.9
• Management Module 201: 192.168.100.10
• Management Module 202: 192.168.100.11
12800-120
:
• Chassis: 192.168.100.9
• Management Module 207: 192.168.100.10
• Management Module 208: 192.168.100.11
12800-180
:
• Chassis: 192.168.100.9
• Management Module 211: 192.168.100.10
• Management Module 212: 192.168.100.11
12800-360
:
• Chassis: 192.168.100.9
• Management Module 227: 192.168.100.10
• Management Module 228: 192.168.100.11
It is necessary for each management module to have a unique IP address for the
following reasons:
• Unique IP addresses are used when sending syslog messages from a management
module to a syslog server.
• Gives the user the ability to ping each management module separately.
• If the IP addresses are not unique, collisions occur, causing IP operations to fail.
To update the IP address on a management module, do the following:
1. Ensure that the module is connected to a COM port on a serial terminal device
through the RS-232 port (12200/12300) or DB-9 port (12800 series).
2. Get to a
[boot]:
prompt by following either Step a or b.
a. If the management module is running and displays the
->
prompt, type the
following command at the console:
reboot now
and press ENTER.
b. If the module is not running, power on the switch.