background image

C49616-003

Intel

®

 RAID Controller

SRCU42X

Hardware

User’s Guide

A p r i l   2 0 0 4

Содержание SRCU42X

Страница 1: ...C49616 003 Intel RAID Controller SRCU42X Hardware User s Guide A p r i l 2 0 0 4 ...

Страница 2: ...RRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not intended for use in medical life saving life sustaining applications Intel may make changes to specifications and product descriptions at any time without notice Intel is a trademark or registered trademark of Intel Corporation or...

Страница 3: ...ce when handling components 6 Do not operate the system with the chassis covers removed A microprocessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves NSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema si...

Страница 4: ...beschriften und ziehen Sie alle Anschlußkabel von den I O Anschlüssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD über blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgemäß montiertes Gehäuse ein Der Mikroprozessor und der Kühler sind möglicherweise erhitzt wenn das System in Bet...

Страница 5: ...03 Canada CE Mark Europe VCCI Mark Japan MIC Mark Korea BSMI DOC Mark Taiwan ACS C Tick Mark Australia PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sistema 3 Togliere tutte le spi...

Страница 6: ...y not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Marking Class B USA EMC Marking Class A Canada CANADA ICES 003 CLASS A CANADA NMB 003 CLASSE A EMC Marking Class B Canada CANADA ICES 003 CLASS B CANADA NMB 003 CLASSE B VCCI Marking Class A Japan VCCI Marking Class B Japan BSMI Marking Class A or B...

Страница 7: ...an experienced radio TV technician for help Intel is not responsible for any radio or television interference caused by unauthorized modification of this equipment for substitution or attachment of connecting cables and equipment other than those specified by Intel The correction of interferences casued by such unauhtorized modification substitution or attachement will be the responsibility of the...

Страница 8: ...overview of the SRCU42X controller Chapter 2 Hardware Installation describes the procedures for installing the SRCU42X controller Chapter 3 Intel RAID Controller SRCU42X Technical Reference describes the technical specifications for the SRCU42X controller Chapter A Glossary of Terms and Abbreviations lists and explains the terms and abbreviations used in this manual Related Publications Intel RAID...

Страница 9: ...omputer If the computer gets wet consult the documentation that came with it Do not push any objects into the openings of your computer Doing so can cause fire or electric shock by shorting out interior components Keep your computer away from radiators and heat sources Also do not block cooling vents Avoid placing loose papers underneath your computer do not place your computer in a closed in wall...

Страница 10: ...to remove any static charge your body may have accumulated In addition to the preceding precautions you can also take the following steps to prevent damage from electrostatic discharge ESD When unpacking a static sensitive component from its shipping carton do not remove the component from the antistatic packing material until you are ready to install the component in your computer Just before unw...

Страница 11: ...20 2 4 After You Have Installed the Storage Adapter 24 Chapter 3 Intel RAID Controller SRCU42X Technical Reference 3 1 Overview 25 3 2 Intel RAID Controller SRCU42X Characteristics 27 3 3 Technical Specifications 27 3 3 1 Storage Adapter Specifications 27 3 3 2 Array Performance Features 28 3 3 3 Fault Tolerance 29 3 3 4 Electrical Characteristics 29 3 3 5 Thermal and Atmospheric Characteristics 2...

Страница 12: ...12 Figures 2 1 Install the Battery Backup Unit 20 2 2 Inserting the SRCU42X Adapter Card in a PCI Slot 21 2 3 Terminating an Internal SCSI Disk Array 23 3 1 Intel RAID Controller SRCU42X Layout 25 ...

Страница 13: ...2 1 Target ID s 21 3 1 Intel RAID Controller SRCU42X Headers and Connectors 26 3 2 Storage Adapter Characteristics 27 3 3 Storage Adapter Specifications 27 3 4 Array Performance Features 28 3 5 Fault Tolerance Features 29 3 6 Maximum Power Requirements 29 ...

Страница 14: ...14 Contents ...

Страница 15: ...l channel has one LSI 53C1030 controller chip that controls two SCSI channels The SRCU42X controller has two VHDCI 68 pin external SCSI connectors and two HDCI 68 pin internal SCSI connectors The SRCU42X controller is a PCI X controller The SRCU42X controller supports a low voltage differential LVD or a single ended SE SCSI bus With LVD you can use cables up to 12 meters long Throughput on each SC...

Страница 16: ...if virtual sizing is enabled More than 200 Qtags per array Hardware clustering support on the board User specified rebuild rate Wide Ultra320 LVD SCSI performance up to 320 Mbytes s Support for up to 1 Gbyte of double data rate DDR SDRAM a 32 64 128 256 or 512 Mbyte or 1 Gbyte DIMM can be installed Support for a 64 bit PCI host interface note that the SRCU42X is a PCI X controller The SRCU42X cont...

Страница 17: ...evices SCSI Channels 2 SCSI Data Transfer Rate Up to 320 Mbytes s per channel SCSI Bus LVD or SE Cache Function Write back requires Battery Backup Unit Write through Adaptive Read Ahead Non Read Ahead Read Ahead Cache I O Direct I O Multiple Logical Drives Arrays per Controller Up to 40 logical drives per controller Maximum of Intel Raid SRCU42X Adapters per System 12 Online Capacity Expansion Yes...

Страница 18: ...t ID Note Configuration on Disk does not work if you change both the SRCU42X controller and the SCSI connectors to different connectors on the new SRCU42X controller It works only if you make one change at a time 1 3 3 Drive Roaming The Intel RAID Controller SRCU42Xs support drive roaming across channels on the same SRCU42X controller Drive roaming lets an Intel Raid SRCU42X controller detect the ...

Страница 19: ... the speed of the slowest device on the bus Intel strongly recommends using an uninterruptible power supply UPS 2 2 Quick Installation The following steps are for for experienced computer users installers Section 2 3 Detailed Installation contains detailed steps 1 Optional required to enable Write Back Cache Attach the Battery Backup Unit to the RAID adapter 2 Turn power off to the server and all ...

Страница 20: ...che Attach the Battery Backup Unit BBU to the adapter a Remove the Battery Backup Unit from its packaging b Connect the wire from the battery to the circuit board A c Position the BBU over the RAID adapter so the connectors line up B Press the BBU onto the adapter d Turn the adapter over e Using three screws C secure the BBU to the RAID adapter Figure 2 1 Install the Battery Backup Unit 3 Power Do...

Страница 21: ... the SRCU42X Adapter Card in a PCI Slot 6 Set the Target IDs Set target identifiers TIDs on the SCSI devices Each device in a channel must have a unique TID Provide unique TIDs for non disk devices CD ROM or tapes regardless of the channel where they are connected The Intel RAID Controller SRCU42X automatically occupies TID 7 which is the highest priority The arbitration priority for a SCSI device...

Страница 22: ...ve Ultra SCSI system and no longer than 3 meters for a 6 drive Ultra SCSI system Use active termination Avoid clustering the cable nodes The cable stub length must be no greater than 0 1 meter 4 inches Use high impedance cables Route SCSI cables carefully 8 Set SCSI Termination The SCSI bus is an electrical transmission line and must be terminated properly to minimize reflections and losses Set te...

Страница 23: ...OS message appears The firmware takes several seconds to initialize During this time the SRCU42X controller scans the SCSI channel s The BIOS Configuration utility prompt times out after several seconds The second portion of the BIOS message displays the Intel RAID Controller SRCU42X number firmware version and cache SDRAM size The numbering of the controllers follows the PCI slot scanning order u...

Страница 24: ...ave Installed the Storage Adapter After installation you must configure the SRCU42X controller and install the operating system driver The Intel RAID Software User s Guide instructs you about the configuration options and how to set them on your SRCU42X controller ...

Страница 25: ...ssor and memory subsystems in a server The component height on the top and bottom of the SRCU42X controller follow the PCI Local Bus Specification Revision 2 2 and PCI X Addendum to the PCI Local Bus Specification Revision 1 0a The Intel RAID Controller SRCU42X is used in PCI X and PCI computer systems with PCI standard bracket types Figure 3 1 Intel RAID Controller SRCU42X Layout J2 J1 J17 Extern...

Страница 26: ...in header LED glows when the onboard cache contains data and a write from the cache to the hard drives is pending J12 BBU Daughter Card 40 pin header Connector for an optional back up battery pack J13 SCSI Activity LED 2 pin header Connector for enclosure LED to indicate data transfers Connection is optional J14 External SCSI Channel 1 Connector 68 pin connector External very high density SCSI bus...

Страница 27: ...BIOS configuration storage LVD SE Signaling Ultra320 SCSI Data Transfers SCSI Features SCSI Termination Yes Yes 16 bit SE or LVD interfaces Up to 320 Mbytes s as well as Fast Ultra Ultra2 and Ultra160 speeds Synchronous offsets up to 62 Plug n Play Scatter Gather Activity LED Active Single Ended or LVD Table 3 3 Storage Adapter Specifications Specification Description Processor PCI Controller Inte...

Страница 28: ...latile Random Access Memory RAM 32 Kbyte 8 for storing RAID configuration Table 3 3 Storage Adapter Specifications Cont Specification Description Table 3 4 Array Performance Features Specification Intel RAID Controller SRCU42X PCI Host Data Transfer Rate 1064 Mbytes s Drive Data Transfer Rate 320 Mbytes s Maximum Scatter Gathers 26 elements Maximum Size of I O Requests 6 4 Mbytes in 64 Kbyte strip...

Страница 29: ...following parameters define the storage and transit environment for the Intel RAID Controller SRCU42X Temperature range 40 C to 105 C dry bulb Relative humidity range 5 to 90 noncondensing Table 3 5 Fault Tolerance Features Specification Intel Raid Controller SRCU42X Support for SMART 1 1 The Self Monitoring Analysis and Reporting Technology SMART detects up to 70 percent of all predictable disk d...

Страница 30: ...roller SRCU42X meets or exceeds the requirements of UL flammability rating 94 V0 Each bare board is also marked with the supplier s name or trademark type and UL flammability rating Since these boards are installed in a PCI bus slot all voltages are below the SELV 42 4 V limit ...

Страница 31: ...d Domain Validation Domain Validation is a software procedure in which a host queries a device to determine its ability to communicate at the negotiated Ultra320 data rate EEPROM Electronically Erasable Programmable Read Only Memory A memory chip typically used to store configuration information See NVRAM External SCSI Device A SCSI device installed outside the computer cabinet These devices are c...

Страница 32: ... adapters and SCSI peripherals SCSI ID A way to uniquely identify each SCSI device on the SCSI bus Each SCSI bus has eight available SCSI IDs numbered 0 through 7 or 0 through 15 for Wide SCSI The storage adapter host adapter usually gets the highest ID 7 or 15 giving it priority to control the bus Single Ended SCSI A hardware specification for connecting SCSI devices It references each SCSI signa...