Detailed Installation
20
2.3
Detailed Installation
This section provides detailed instructions for installing a Intel RAID Controller SRCU42X.
1) Unpack
Unpack and remove the SRCU42X controller. Inspect it for damage. If it appears
damaged, or if any items listed below are missing, contact your Intel support
representative. The Intel RAID Controller SRCU42X is shipped with:
◊
The Resource CD, which contains Intel RAID drivers for supported operating
systems, an electronic version of this guide, and other related documentation.
◊
A license agreement
2) (Optional, required to enable Write Back Cache) Attach the Battery Backup Unit (BBU)
to the adapter.
a.
Remove the Battery Backup Unit from its packaging.
b.
Connect the wire from the battery to the circuit board (A).
c.
Position the BBU over the RAID adapter so the connectors line up (B). Press the
BBU onto the adapter.
d. Turn the adapter over.
e.
Using three screws (C), secure the BBU to the RAID adapter.
Figure 2.1
Install the Battery Backup Unit
3) Power Down the System
Turn off the computer and remove the AC power cord. Remove the system’s cover. See
the system documentation for instructions.
4) Check the Jumpers
Ensure that the jumper settings on the your SRCU42X controller are correct. See
Chapter 3, “Intel RAID Controller SRCU42X Technical Reference,” for diagrams of the
SRCU42X controllers with their jumpers and connectors.