background image

Intel® RAID Controller SRCSAS18E User’s Guide

16

Figure 7 displays the SAS cables used to connect the RAID Controller SRCSAS18E to an 

expander board. Perform the following steps to connect a RAID Controller SRCSAS18E 

to an expander board, as shown in Figure 7.

1. Plug the 7-wire connector on the cable into the connector on a SAS RAID controller.
2. Plug the connector on the other end of the cable into the connector on an expander 

board. 

Figure 7. RAID Controller SRCSAS18E to an Expander Board

Serial Signal

Cables

RSA to HDD Breakout Cable

To Expander Board

Ports

0 – 3

Ports

4 – 7

Содержание SRCSAS18E - RAID Controller

Страница 1: ...Intel RAID Controller SRCSAS18E User s Guide Intel Order Number D26788 003...

Страница 2: ...CLUDING LIABILITY OR WARRAN TIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE MERCHANTABILITY OR INFRINGEMENT OF ANY PATENT COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT Intel products are not intend...

Страница 3: ...e back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling compo...

Страница 4: ...die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System...

Страница 5: ...6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le syst me a t sous tension Faites galement attention aux...

Страница 6: ...adapter plugs or remove the grounding prong from a cable If you must use an extension cable use a 3 wire cable with properly grounded plugs To help protect your computer system from sudden transient...

Страница 7: ...static damage discharge static electricity from your body before you touch any of your computer s electronic components such as the microprocessor You can do so by touching an unpainted metal surface...

Страница 8: ...ICES 003 USA Canada CISPR 22 International EN55022 Europe EN55024 Europe CE EMC Directive 89 336 EEC Europe VCCI Japan AS NZS 3548 Australia New Zealand BSMI CNS13438 Taiwan RRL MIC Notice No 1997 41...

Страница 9: ...this device is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause un...

Страница 10: ...x Intel RAID Controller SRCSAS18E User s Guidel BSMI Marking Class A or B and Class A EMC Warning Taiwan RRL MIC Mark Korea C Tick Mark Australia Regulatory Compliance Country Marking...

Страница 11: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and th...

Страница 12: ...ked with the CE Mark to illustrate its compliance RRL Korea English translation of the notice above 1 Type of Equipment Model Name Model name on product 2 Certification No On RRL certificate Obtain ce...

Страница 13: ...m this book are Engineers who are designing a RAID Controller SRCSAS18E storage adapter into a system Anyone installing a RAID Controller SRCSAS18E storage adapter in their RAID system Organization Th...

Страница 14: ...xiv Intel RAID Controller SRCSAS18E User s Guidel...

Страница 15: ...PCI Performance 5 Flexibility 6 Drive Roaming 6 Drive Migration 7 Hardware Specifications 8 Chapter 2 Intel RAID Controller SRCSAS18E Hardware Installation 9 Requirements 9 Quick Installation 10 Deta...

Страница 16: ...xvi Intel RAID Controller SRCSAS18E User s Guidel...

Страница 17: ...ard in a PCI Express Slot 11 Figure 3 Internal SAS Cable for Connection to SAS and SATA Hard Disk Drives 13 Figure 4 Serial ATA Connectors 13 Figure 5 SAS and SATA Plugs and SAS Backplane Receptacle C...

Страница 18: ...xviii Intel RAID Controller SRCSAS18E User s Guide...

Страница 19: ...s Table 1 Intel RAID Controller SRCSAS18E Overview 8 Table 2 Jumper Descriptions 19 Table 3 Card Characteristics 20 Table 4 Specifications 21 Table 5 Array Performance Features 22 Table 6 Fault Tolera...

Страница 20: ...e expanders to connect to additional drives See the ANSI SAS standard version 1 0 specification for more information about the use of expanders As the second generation PCI Express storage adapter the...

Страница 21: ...addition the SAS RAID controller supports the following SATA features 3 Gbit s SATA Staggered spin up Hot Plug Native Command Queuing NCQ Note Available with TA D46199 003 or later only Activity and f...

Страница 22: ...plified cabling smaller connectors lower pin count and lower power requirements when compared to parallel SCSI SAS controllers leverage a common electrical and physical connection interface that is co...

Страница 23: ...systems supported by this controller may not be supported by your server board See the tested operating system list for your server board at http support intel com support motherboards server See als...

Страница 24: ...ides a scalable interface that supports up to 128 devices through multiple expanders Supports wide ports consisting of 2 3 or 4 phys within a single quad port Supports narrow ports consisting of a sin...

Страница 25: ...ts on the same controller When the drives are placed on different ports the controller detects the RAID configuration from the configuration data on the drives Note If you move a drive that is current...

Страница 26: ...drives enclosures and system components then disconnect power cords from the systems 3 Open the host systems by following the instructions in the host system technical documentation 4 Remove the SAS...

Страница 27: ...t Ports Two internal connectors that support up to four ports per connector Data Transfer Rate Up to 3 Gbits s per port Cache Function Write back Write through Adaptive Read Ahead Non Read Ahead Read...

Страница 28: ...S Device Cables Replacing a Failed Controller that Contains Data in the Intel RAID Portable Cache Module 2 After Installing the Storage Adapter Requirements The following items are required to install...

Страница 29: ...alled Close the server chassis 7 Reconnect power cable and turn on power Detailed Installation This section provides detailed instructions for installing a RAID Controller SRCSAS18E 1 Unpack the Stora...

Страница 30: ...t as shown in Figure 2 Secure the bracket to the computer chassis Figure 2 Inserting the Intel RAID Controller SRCSAS18E Card in a PCI Express Slot 6 Connect SAS or SATA Devices to the Storage Adapter...

Страница 31: ...e a SAS or SATA device the device might not be recognized During the boot a BIOS message appears The firmware takes several seconds to initialize The configuration utility prompt times out after sever...

Страница 32: ...o connect a SAS RAID controller with internal connector to the host receptable connector on a backplane A SATA connector consists of a signal connector and a power connector Figure 4 Serial ATA Connec...

Страница 33: ...nector and SATA connector is the bridge between the SAS primary physical link and power connector on the SAS controller Note SAS backplane connectors can accept SAS or SATA hard disk drives but SATA b...

Страница 34: ...ectly to the SAS backplane or SATA hard disk drives as shown in Figure 6 1 Plug the 7 wire connector on the internal cable into the connector on a SAS RAID controller 2 Plug the connector on the other...

Страница 35: ...a RAID Controller SRCSAS18E to an expander board as shown in Figure 7 1 Plug the 7 wire connector on the cable into the connector on a SAS RAID controller 2 Plug the connector on the other end of the...

Страница 36: ...Intel RAID Portable Cache Module 2 into the replacement controller 5 Connect the battery cable to the connector on the Intel RAID Portable Cache Module 2 6 Insert the replacement controller into the s...

Страница 37: ...er SRCSAS18E installation you must configure the storage adapter and install the operating system driver The Software User s Guide instructs you on the configuration options and how to set them on you...

Страница 38: ...O architecture for various systems desktops workstations mobile server communications and embedded devices Figure 8 displays the connectors and headers on the controller and Table 2 describes them Fi...

Страница 39: ...ge file J10 Dirty cache LED 2 pin connector Connect to enclosure LED to indicate data in cache has not been written to disk J15 Debug header 4 pin connector Factory debug use only J18 I2 C SES2 4 pin...

Страница 40: ...ocessor PCI Controller Intel 80333 I O processor at 500 MHz Operating Voltage 3 3 V 12 V Card Size Standard height full length PCI Express adapter card size 4 376 x 9 5 Array Interface to Host PCI Exp...

Страница 41: ...Drive As many as the drive can accept Stripe Sizes 8 16 32 64 or 128 Kbyte Maximum Number of Concurrent Commands 255 Support for Multiple Initiators Yes Table 6 Fault Tolerance Features Specification...

Страница 42: ...he maximum operating temperature decreases to 45 C when the Intel RAID Portable Cache Module 2 battery backup unit is installed Relative humidity range 5 to 90 non condensing Note The maximum operatin...

Страница 43: ...ation information It provides stable storage for long periods without electricity and can be reprogrammed See NVRAM External SAS Device A SAS device installed outside the computer cabinet These device...

Страница 44: ...ntrollers leverage a common electrical and physical connectioin interface that is compatible with Serial ATA The SAS controllers support the ANSI Serial Attached SCSI standard version 1 0 In addition...