Getting Started
25
Configurable SCSI Parameters
When a SCSI hard disk drive is initialized the first time by the RAID controller, its SCSI
parameters are automatically set to their optimal settings. Manual configuration is not required.
However, the RAID controller allows for the custom configuration of several SCSI parameters on a
hard disk drive-by-hard disk drive basis. There are several settings that can be configured by using
the Storage Console menu Advanced Setup
Å
Configure Physical Devices
Å
Select Physical Drive
Å
SCSI Parameter/Initialize. Most settings are set automatically and can not be configured
manually.
Table 1.
Disk Drive SCSI Parameters
Parameter
Setting/Value
Description
Synch. Transfer
Not
Configurable
This setting when enabled allows the controller to operate in
synchronous transfer mode.
Synch. Transfer
Rate
Not
Configurable
Allows for the setting of the speed for the SCSI hard disks (160 MB/sec
for U160 drives). No matter the setting, the SCSI bus will negotiate the
fastest speed up to this setting. Lowering the setting will force the disk
drive to transfer at the lower speed.
Disconnect
Not
Configurable
Enabling this setting allows for the disk drive to disconnect from the
SCSI bus when it’s not participating in a transfer. This allows for
optimal bus utilization by all devices on the bus.
Tagged Queues
Not
Configurable
When enabled, this feature allows the SCSI disk drive to execute more
than one command at a time.
Disk Read and
Write Cache
On / Off
For performance reasons, the Read Ahead and Write cache of the hard
disk drives should always be on.
Domain
Validation
Not
Configurable
Using the <F4> key while in this menu accesses this parameter. When
this is set to
On
, Domain validation allows for a cyclical check of the
correct data transfer at a given rate.
Содержание SRCMR
Страница 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Страница 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Страница 44: ...44 Intel RAID Controller SRCMR User s Guide...
Страница 52: ...52 Intel RAID Controller SRCMR User s Guide...
Страница 68: ...68 Intel RAID Controller SRCMR User s Guide...
Страница 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Страница 122: ...122 Intel RAID Controller SRCMR User s Guide...
Страница 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Страница 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Страница 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Страница 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Страница 180: ...180 Intel RAID Controller SRCMR User s Guide...