background image

xiv

Intel

®

 Server System SR1680MV Service Guide

BIOS POST Beep Codes  .......................................................................................... 116

Appendix C: Installation/Assembly Safety Instructions  .....................................119

English ............................................................................................................................... 119
Deutsch ............................................................................................................................. 121
Français ............................................................................................................................. 123
Español ............................................................................................................................. 125
Italiano ............................................................................................................................... 127

Appendix D: Safety Information  ............................................................................131

English ............................................................................................................................... 131

Server Safety Information  ......................................................................................... 131
Safety Warnings and Cautions .................................................................................. 131
Intended Application Uses  ........................................................................................ 132
Site Selection  ............................................................................................................ 132
Equipment Handling Practices  .................................................................................. 132
Power and Electrical Warnings  ................................................................................. 133
Access Warnings  ...................................................................................................... 133
Electrostatic Discharge (ESD) ................................................................................... 134
Other Hazards ........................................................................................................... 134

Deutsch ............................................................................................................................. 135

Sicherheitshinweise für den Server ........................................................................... 135
Sicherheitshinweise und Vorsichtsmaßnahmen  ....................................................... 136
Zielbenutzer der Anwendung  .................................................................................... 136
Standortauswahl ....................................................................................................... 136
Handhabung von Geräten ......................................................................................... 137
Warnungen zu Netzspannung und Elektrizität  .......................................................... 138
Warnhinweise für den Systemzugang ....................................................................... 138
Elektrostatische Entladungen (ESD) ......................................................................... 139
Andere Gefahren ....................................................................................................... 140

Français ............................................................................................................................. 141

Consignes de sécurité sur le serveur ........................................................................ 141
Sécurité: avertissements et mises en garde  ............................................................. 141
Domaines d’utilisation prévus  ................................................................................... 142
Sélection d’un emplacement  ..................................................................................... 142
Pratiques de manipulation de l’équipement  .............................................................. 142
Alimentation et avertissements en matière d’électricité  ............................................ 143
Avertissements sur l’accès au système  .................................................................... 143
Décharges électrostatiques (ESD) ............................................................................ 144
Autres risques  ........................................................................................................... 144

Español ............................................................................................................................. 145

Información de seguridad del servidor  ...................................................................... 145
Advertencias y precauciones sobre seguridad  ......................................................... 145
Aplicaciones y usos previstos  ................................................................................... 146
Selección de la ubicación .......................................................................................... 146

Содержание SR1680MV - Server System - 0 MB RAM

Страница 1: ...Intel Server System SR1680MV Service Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number E74835 005...

Страница 2: ...may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflo...

Страница 3: ...em features photos of the product and product diagrams to help you identify components and their locations Chapter 2 provides instructions on adding and replacing components Use this chapter for step...

Страница 4: ...urchase one or more of the following accessory items for your server Processor memory DIMMs hard drive and operating system For information about which accessories memory processors and third party ha...

Страница 5: ...eived this product and need to install it Intel Server System SR1680MV Quick Start User s Guide in the product box Accessories or other Intel server products Spares and Configuration Guide Hardware pe...

Страница 6: ...vi Intel Server System SR1680MV Service Guide...

Страница 7: ...eh usen auf der Intel Server Resource CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mise...

Страница 8: ...viii Intel Server System SR1680MV Service Guide http support intel com support motherboards server sb CS 010770 htm QWHO 6HUYHU RDUGV DQG 6HUYHU KDVVLV 6DIHW QIRUPDWLRQ QWHO...

Страница 9: ...mage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation...

Страница 10: ...x Intel Server System SR1680MV Service Guide...

Страница 11: ...assis Layout 3 Front View Components 4 Back View Components 4 Buttons and System LEDs 5 Front Panel Buttons and LEDs 5 Rear Panel Button and LEDs 6 LED Information 6 Chapter 2 Hardware Installations a...

Страница 12: ...Pluggable SATA HDD Backplane 33 System Fans 33 Removing a System Fan 34 Installing a System Fan 35 Air Duct 35 Removing the IOB Air Duct 35 Installing Air Ducts 36 PCI E Cage 36 Removing a PCI E Cage...

Страница 13: ...ity Menu 91 Trusted Computing Submenu 93 Exit Menu 95 BIOS Updates 96 ROM Flash 96 Chapter 6 Embedded SATA RAID 99 Enabling RAID in the BIOS Setup 99 Chapter 7 Installing the Rackmount Rail Kits 101 P...

Страница 14: ...ichtsma nahmen 136 Zielbenutzer der Anwendung 136 Standortauswahl 136 Handhabung von Ger ten 137 Warnungen zu Netzspannung und Elektrizit t 138 Warnhinweise f r den Systemzugang 138 Elektrostatische E...

Страница 15: ...ompliance 158 Product EMC Compliance Class A Compliance 158 Product Ecology Compliance 159 Certifications Registrations Declarations 159 Product Regulatory Compliance Markings 160 Rack Mount Installat...

Страница 16: ...xvi Intel Server System SR1680MV Service Guide...

Страница 17: ...ng the Retaining Clips Outward 22 Figure 21 Inserting the DIMM into the Socket 22 Figure 22 Server Board Cage Module with 2 5 inch Pluggable SATA HDD Location 23 Figure 23 Releasing the Locking Latch...

Страница 18: ...Server Board 47 Figure 55 Connectors and Component Locations of IO Boards 49 Figure 56 Connectors and Component Locations of NIC Board 50 Figure 57 Connectors and Component Locations of Front Panel 51...

Страница 19: ...le 19 Super IO Chipset Submenu 74 Table 20 SATA Configuration Submenu Fields 75 Table 21 USB Configuration Submenu 76 Table 22 USB Configuration Submenu Fields 76 Table 23 USB Mass Storage Device Conf...

Страница 20: ...4 Recommended screwdrivers 101 Table 45 Location and Adapt Depth for Racks 102 Table 46 Resetting the System 111 Table 47 LED Information 116 Table 48 POST Error Beep Codes 116 Table 49 Error Beep Cod...

Страница 21: ...placement Based on the Intel 5500 chipset platform each server board uses high performance dual processors of the Intel Xeon 5500 Series Intel Xeon 5600 Series and Intel ICH10R chipsets Two server boa...

Страница 22: ...ximum per unbuffered DIMM Supports single rank SR dual rank DR and quad rank QR DIMM modules On board LAN Dual Gigabit Ethernet ports Network controllers embedded in Intel 82576 chipsets Interface com...

Страница 23: ...sis Layout Figure 2 Layout of Server Chassis with 2 5 inch Pluggable HDDs 1 Power Supply 6 Server boards 2 I O Boards 7 Pluggable HDD Backplane 3 PCI E Cage 8 Pluggable HDD Bays 4 System Fans 9 NIC Ca...

Страница 24: ...he following introduces the front view of the server with 2 5 inch pluggable HDDs Figure 3 Front View of Server with 2 5 inch Pluggable HDDs Back View Components The server back view includes connecto...

Страница 25: ...w constant monitoring of basic system functions while the server is operating These LEDs provide visual cues to the status of NIC link system health UID unique identifier and power The following figur...

Страница 26: ...Back View LEDs and Buttons of Two I O Boards The following table provides detailed LED information LED Information 1 Rear UID Buttons 4 NIC 1 2 Link LEDs 2 Rear UID LEDs 5 AC Power LED 3 NIC 1 2 Activ...

Страница 27: ...No drive activity NIC 1 2 LED Green Blinking Linked and activity on the network On Linked to network Off LAN not connected UID LED Blue Blinking Command trigger On Identification Off Disabled Back Vie...

Страница 28: ...8 Intel Server System SR1680MV Service Guide...

Страница 29: ...h permits to remove or install the components without any tools The locking tab retaining clip and so forth provide the convenient method to lock the components on the server chassis The tool less com...

Страница 30: ...Caution To reduce the risk of injury from electric shock remove the power cord to completely disconnect power from the system Warning Moving the Power On Off switch to the Off position does not compl...

Страница 31: ...the replacement of internal components convenient Note Before you remove or install the rear top cover follow this step 1 Make sure the server is not turned on or connected to the AC power To power o...

Страница 32: ...des two surface mount LGA 1366 CPU sockets designed for the Intel Xeon Processor 5500 series and Intel Xeon Processor 5600 series One server node can be configured to either a single or dual processor...

Страница 33: ...s use the same type of processor running at the same frequency Note Before you remove or install the heatsink processor or heatsink socket complete the following steps 1 Make sure the server is not tu...

Страница 34: ...14 Intel Server System SR1680MV Service Guide Figure 12 Lifting the Processor Out of the Socket 4 Place the PnP cap onto the load plate Figure 13 Placing on the PnP Cap...

Страница 35: ...ock the load lever Figure 14 Closing the Load Plate Installing the Processor Reverse the steps in Removing the Processor to install the processor However when inserting the processor into the socket m...

Страница 36: ...secure the processor The lever clicks on the socket indicating it is locked The processor fits only in one orientation Do not force the processor into the socket to avoid bending the pins and damaging...

Страница 37: ...tely on the bottom of the heatsink Put the two heatsinks with the 16 fin side facing the corresponding DIMM group System Memory Each motherboard supports 18 DDR3 1333 1066 800 DIMMs depending on DIMM...

Страница 38: ...Service Guide Figure 17 Location of System Memories There are 18 DIMMs on the motherboard to support processor 1 and processor 2 The DIMM sequence of 18 DIMM sockets is respectively shown in Figure 18...

Страница 39: ...mirroring the total physical memory available to the system is half of what is populated Mirrored Channel Mode requires that Channel 0 and Channel 1 must be populated identically with regards to size...

Страница 40: ...tered DIMMs only configuration 1 6 could be supported Optional Note For other Registered DIMMs configuration 1 9 could be supported Table 3 Ideal DIMM Installation Options for A C Channels of Processo...

Страница 41: ...off the server see Power Off 2 Remove the chassis cover To remove the cover see Mid Top Cover Removing a DIMM 1 Unlock a DIMM socket by pressing the retaining clips outward This action releases the mo...

Страница 42: ...uide Figure 20 Pressing the Retaining Clips Outward 2 Align the notch on the DIMM to the break on the socket Carefully insert the DIMM into the socket until the retaining clips snap back in place Figu...

Страница 43: ...ith 2 5 inch Pluggable SATA HDD Location Warning When installing the server board cage module make sure that you place it into the chassis correctly The edge with the external ports goes to the back p...

Страница 44: ...lever along the direction of the arrow to remove the module Figure 24 Pull the Locking Lever to Remove the Server Board Cage Module Installing the Server Board Cage Module Reverse the Removing the Ser...

Страница 45: ...right I O board cage modules on the server chassis is shown in the following figures Figure 25 Left I O Board Cage Module Location Figure 26 Right I O Board Cage Module Location Note Before you remov...

Страница 46: ...w 2 The cage tray lever springs open by itself Figure 27 Slide the Locking Latch 3 Pull the cage tray lever along the direction of the arrow to remove the module Figure 28 Pull the Locking Lever to Re...

Страница 47: ...wer supply complete the following steps 1 Make sure the server is not turned on or connected to the AC power To power off the server see Power Off 2 Disconnect all necessary cable connections Removing...

Страница 48: ...istribution Board This section introduces the replacement procedures of the power distribution board Figure 31 shows the location of the power distribution board on the server chassis Figure 31 Power...

Страница 49: ...sconnect all necessary cable connections Removing the Power Distribution Board 1 Lift the power distribution board from the chassis Figure 32 Removing the Power Distribution Board Installing the Power...

Страница 50: ...e location of the 2 5 inch pluggable SATA HDD on the server chassis Figure 33 2 5 inch Pluggable SATA HDD Location Note Before you remove or install the pluggable HDD complete the following steps 1 Ma...

Страница 51: ...ure 34 Release the Locking Lever 4 Pull the HDD carrier locking lever out along the direction of the arrow Figure 35 Pull the Locking Lever to Remove the HDD Carrier 5 Loosen and remove the four secur...

Страница 52: ...nch Pluggable HDD Backplane Each server board module supports one 2 5 inch pluggable HDD backplane two HDD backplanes share the same removal and installation procedure For your reference this section...

Страница 53: ...the backplane 2 Lift the backplane up from motherboard Figure 38 Remove the Screws and Lift the Backplane Up Installing a 2 5 inch Pluggable SATA HDD Backplane Reverse the Removing an HDD Backplane s...

Страница 54: ...is not turned on or connected to the AC power To power off the server see Power Off 2 Remove the left and right I O board cage modules To remove the cover see Left and Right I O Board Cage Modules 3...

Страница 55: ...1 Make sure the server is not turned on or connected to the AC power To power off the server see Power Off 2 Remove the left and right IO board cage modules To remove the cover see Left and Right I O...

Страница 56: ...t I O board cage module as an example Figure 42 shows the location of the PCI E cage on the right I O board cage module Figure 42 PCI E Cage Location Note Before you remove or install the PCI E cage c...

Страница 57: ...Module 2 Loosen and remove the securing screw 3 Pull out the expansion card with the slot cover from the PCI E cage Figure 44 Removing the Expansion Card 4 Insert the slot cover to the right position...

Страница 58: ...ving the Riser Card Installing a PCI E Cage Reverse the Removing a PCI E Cage steps to install the PCI E cage Daughter Cards Optional There are two optional daughter cards supported by each IO board T...

Страница 59: ...omplete the following steps 1 Make sure the server is not turned on or connected to the AC power To power off the server see Power Off 2 Remove the left and right IO board cage modules To remove the c...

Страница 60: ...Server System SR1680MV Service Guide Figure 49 Lifting the Module Upward from the IO Board 2 Remove the I O Expansion module out of the IO board module Figure 50 Removing the Module Upward from the I...

Страница 61: ...Intel Server System SR1680MV Service Guide 41 Installing the IO Expansion Module Reverse the steps in the Removing the IO Expansion Module to install the IO Expansion module...

Страница 62: ...42 Intel Server System SR1680MV Service Guide...

Страница 63: ...ide 43 3 Cable Connections Connectors and Pin 1 Locations Figure 51 shows the different locations of the connectors and their pin 1 locations which can help you connect the cables Figure 51 Locations...

Страница 64: ...s correctly and conveniently There are two ways for you to judge how to connect the cables 1 When there is no fool proof feature on this connector you should connect the red margin of the cable to the...

Страница 65: ...Intel Server System SR1680MV Service Guide 45 Figure 53 Connecting the System Fan Cables...

Страница 66: ...46 Intel Server System SR1680MV Service Guide...

Страница 67: ...Connector 4 SATA Power Connector J47 5 Server board SATA4 Connector J29 6 Server board SATA3 Connector J31 7 Processor 1 CPU 1 8 DIMM Socket Group J7 J8 J9 J10 J11 J12 J13 J14 J15 9 Server board Powe...

Страница 68: ...48 Intel Server System SR1680MV Service Guide 17 Front UID LED 18 Front UID Button 19 Power Button 20 System Health LED 21 Power LED 22 Front USB Ports 23 NIC LED 24 HDD LED 25 Serial Port 26 VGA Port...

Страница 69: ...Description Location Description Location Left Right Left Right 1 PCI E x8 Slots J5 J5 2 IO Board IO Connector J10 J10 3 System Fan1 Connectors J6 J7 4 System Fan2 Connectors J8 J9 5 System Fan3 Conne...

Страница 70: ...50 Intel Server System SR1680MV Service Guide Connector and Component Locations of NIC Board Figure 56 Connectors and Component Locations of NIC Board 1 Connector 2 Rear NIC2 Port 3 Rear NIC1 Port...

Страница 71: ...nd Components of Front Panel Figure 57 Connectors and Component Locations of Front Panel 1 Front VGA Port 2 Front Serial Port 3 NIC LED 4 Front USB Port 5 System Health LED 6 Power Button 7 Front UID...

Страница 72: ...tel Server System SR1680MV Service Guide 10 GB IO Card Optional Daughter Card Figure 58 Connectors and Components of 10 GB IO Card 1 PCI E 2 Connector 2 PCI E 1 Connector 3 10 GB IO Port1 4 10 GB IO P...

Страница 73: ...ntel Server System SR1680MV Service Guide 53 InfiniBand Card Optional Daughter Card Figure 59 Connectors and Components of InfiniBand Card 1 PCI E 2 Connector 2 PCI E 1 Connector 3 InfiniBand CX4 Port...

Страница 74: ...mponent Locations of HDD Backplane Figure 60 Connectors and Components of 2 5 inch Pluggable HDD Backplane 1 HDD 0 Fail LED CR4 2 HDD 1 Fail LED CR2 3 HDD 1 Active LED CR1 4 SATA 1 Connector J3 5 HDD...

Страница 75: ...er and the other is an ICH functions jumper Two jumpers are divided into five pin groups refer to Figure 62 Location of MISC Jumper on page 56 and Figure 63 Location of ICH Function Jumper on page 57...

Страница 76: ...56 Intel Server System SR1680MV Service Guide Figure 62 Location of MISC Jumper Jumper Function A Reserved B Clear BMC Password C Reserved D Reserved E Reserved F Reserved G Reserved H Reserved...

Страница 77: ...Intel Server System SR1680MV Service Guide 57 Figure 63 Location of ICH Function Jumper Jumper Function A Clear CMOS B Clear Password C Recovery RWH D BIOS Protect E RTC Reset...

Страница 78: ...58 Intel Server System SR1680MV Service Guide...

Страница 79: ...utility that provides the means to configure the platform The BIOS Setup utility is part of the system BIOS and allows limited control over onboard resources The user can disable embedded PCI devices...

Страница 80: ...options may or may not be changed If an option cannot be changed due to the security level its selection field is made inaccessible The Keyboard Command Bar supports the following Options Menu Each Op...

Страница 81: ...the Enter key Select Menu The left and right arrow keys are used to move between the major menu pages The keys have no affect if a sub menu or pick list is displayed Tab Select Field The Tab key is u...

Страница 82: ...p defaults of BIOS Setup Utility Menu F10 Save and Exit Pressing F10 causes the following message to display Setup Confirmation Save Configuration changes and exit setup OK Cancel If OK is selected an...

Страница 83: ...6144 MB System Time 09 52 34 System Date Fri 11 14 2008 Use ENTER TAB or SHIFT TAB to select a field Select Screen Select Item Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit...

Страница 84: ...ng wrong values in below sections may cause system to malfunction CPU Configuration Memory Configuration SATA Configuration Super IO Configuration USB Configuration PCI Configuration IPMI Configuratio...

Страница 85: ...es All Intel SpeedStep tm tech Enabled Intel C STATE tech Disabled For UP platforms leave it enabled For DP MP servers it may use to tune performance to the specific application Select Screen Select I...

Страница 86: ...rovided by Intel Virtualization Tech Note A full reset is required to change the setting Execute Disable Bit Capability Disabled Enabled When disabled force the XD feature flag to always return 0 Acti...

Страница 87: ...y IDE Slave Secondary IDE Master Hard Disk Write Protect IDE Detect Time Out Sec Compatible Configure the IDE device s NOTE1 As Compatible only support IDE mode Configure SATA AS will be hidden when S...

Страница 88: ...er Primary IDE Slave Secondary IDE Master Secondary IDE Slave Hard Disk Write Protect IDE Detect Time Out Sec IDE Configure the IDE device s Options Disabled Compatible Enhanced Select Screen Select I...

Страница 89: ...ORT 2 SATA PORT 3 SATA PORT 4 Hard Disk Write Protect IDE Detect Time Out Sec ATA PI 80Pin Cable Detection RAID Configure the IDE device s Select Screen Select Item Change Field Enter Go to Sub Screen...

Страница 90: ...e SATA AS AHCI PORT1 AHCI PORT2 AHCI PORT3 AHCI PORT4 Hot Plug Hard Disk Write Protect IDE Detect Time Out Sec AHCI Configure the IDE device s Select Screen Select Item Change Field Enter Go to Sub Sc...

Страница 91: ...Options Disabled Compatible Enhanced Configure SATA as IDE RAID AHCI Options IDE RAID AHCI Hot Plug Enable Disabled Options Enable Disabled Hard Disk Write Protect Disabled Enable Disable Enable devi...

Страница 92: ...IDE Master Device Type Drive Write Cache Block Multi Sector Transfer LBA Large Mode PIO Mode DMA Mode Auto S M A R T 32Bit Data Transfer Not Detected Select Screen Select Item Change Option Enter Go...

Страница 93: ...LBA Large Mode Disabled Auto Disabled Disables LBA Mode Auto Enables LBA Mode if the device supports it and the device is not already formatted with LBA Mode disabled Block Multi Sector Transfer Disab...

Страница 94: ...nu BIOS Setup Utility Main Advanced Boot Security Exit Configure PILOT Super IO Chipset Serial Port Address 3F8 IRQ4 Configure Super IO Chipset PILOT Select Screen Select Screen Change Field Tab Selec...

Страница 95: ...ice Guide 75 Table 20 SATA Configuration Submenu Fields Menu Fields Settings Description Advanced Super IO Configuration Serial Port Address Disabled 3F8 IRQ4 2F8 IRQ3 3F8 IRQ4 2F8 IRQ3 Allows BIOS to...

Страница 96: ...d BIOS EHCI Hand Off Enabled Hotplug USB FDD Support Auto USB Mass Storage Device Configuration Configure the USB support Select Screen Select Screen Change Field Tab Select Field F1 General Help F10...

Страница 97: ...is is a workaround for operating systems without EHCI hand off support The EHCI ownership change should claim by EHCI driver Hotplug USB FDD Support Disabled Enabled Auto A dummy FDD device is created...

Страница 98: ...Security Exit USB Mass Device Storage Configuration USB Mass Storage Reset Delay 20 Sec Device 1 AMI Virtual CDROM Emulation Type Auto Device 1 AMI Virtual Floppy N Emulation Type Auto Configure the...

Страница 99: ...torage Reset Delay 10 Sec 20 Sec 30 Sec 40 Sec Number of seconds POST waits for the USB mass storage device after start unit command Emulation Type Auto Floppy Forced FDD Hard Disk CDROM If Auto USB d...

Страница 100: ...er Management Disabled Configure PCI Express support Select Screen Select Screen Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02 61 Copyright 1985 2006 American Megatrends...

Страница 101: ...iguration Status of BMC Working BMC Firmware Revision 0 31 View BMC System Event Log Clear BMC System Event Log Disable PEF No Restore on AC Power Loss Power Off IPMI configuration including server mo...

Страница 102: ...Fields Settings Description Advanced USB Configuration Disable PEF No Yes Yes or No to disable PEF in BMC after exiting SETUP It only affects once and then will be changed to No when Yes is selected...

Страница 103: ...pe 02 System Event Event Timestamp 12 s from SEL init Generator ID 0020 Event Message Format Ver 04 IPMI ver 2 0 Event Sensor Type 09 Power Unit Event Sensor Number 74 Event Dir Type EF Event Data 04...

Страница 104: ...Exit Remote Access Enabled Configure Remote Access Select Screen Select Screen Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02 61 Copyright 1985 2006 American Megatrends...

Страница 105: ...ain Advanced Boot Security Exit Boot Settings Boot Settings Configuration Boot Device Priority Removable Devices CD DVD Drives Configure Settings during System Boot Select Screen Select Screen Change...

Страница 106: ...e booting This will decrease the time needed to boot the system Select Screen Select Screen Change Field Tab Select Field F1 General Help F10 Save and Exit ESC Exit V02 61 Copyright 1985 2006 American...

Страница 107: ...IOS Keep Current Set display mode for Option ROM Bootup Num Lock Off On Select Power on state for Numlock Interrupt 19 Capture Disabled Enabled Enabled Allows option ROMs to trap interrupt 19 Table 34...

Страница 108: ...vice Priority 1st Boot Device Network IBA GE Slo 2nd Boot Device Network IBA GE Slo Specifies the boot sequence from the available devices A device enclosed in parenthesis has been disabled in the cor...

Страница 109: ...BIOS Setup Utility Main Advanced Boot Security Exit Removable Drives 1st Drive USB AMI Virtual F1 Specifies the boot sequence from the available devices Select Screen Select Screen Change Field Tab Se...

Страница 110: ...IOS Setup Utility Main Advanced Boot Security Exit CD DVD Drives 1st Drive USB AMI Virtual CD Specifies the boot sequence from the available devices Select Screen Select Screen Change Field Tab Select...

Страница 111: ...ssword Not Installed User Password Not Installed Change Supervisor Password Boot Sector Virus Protection Disabled Trusted Computing Power Reset Switches Inhibit Disabled NMI Control Switch Inhibit Dis...

Страница 112: ...password while invoking setup Always Check password while invoking setup as well as on each boot Boot Sector Virus Protection Disabled Enabled Enabled Disabled Boot Sector Virus Protection Power Rese...

Страница 113: ...Submenu BIOS Setup Utility Main Advanced Boot Security Exit Trusted Computing TCG TPM Support No Enable Disable TPM TCG TPM 1 1 1 2 support in BIOS Select Screen Select Screen Change Field Tab Select...

Страница 114: ...System SR1680MV Service Guide Table 41 Trusted Computing Submenu Fields Menu Fields Settings Description Advanced Boot Settings Configuration TCG TPM SUPPORT No Yes Enable Disable TPM TCG TPM 1 1 1 2...

Страница 115: ...dvanced Chipset Settings Save Changes and Exit Discard Changes and Exit Load Optimal Defaults Load Failsafe Defaults Exit system setup after saving the changes F10 key can be used for this operation S...

Страница 116: ...t Block 4 Restart system load BIOS default value Recovery Mode Prepare USB disk on key or Floppy disk CD ROM for recovery 1 Format USB Disk on Key or Floppy disk CD ROM with FAT16 FAT32 format 2 Copy...

Страница 117: ...Intel Server System SR1680MV Service Guide 97 4 Unplug USB Disk on Key or Floppy CD ROM Turn off the Recovery Jumper 5 Restart system load BIOS default...

Страница 118: ...98 Intel Server System SR1680MV Service Guide...

Страница 119: ...osoft Windows operating systems Enabling RAID in the BIOS Setup By default the BIOS does NOT enable RAID support To enable this feature you must set an option in the BIOS setup as described in the fol...

Страница 120: ...100 Intel Server System SR1680MV Service Guide...

Страница 121: ...ference to secure or loosen the corresponding screws Table 44 Recommended screwdrivers There are seven spring screw holes in rail to secure each spring Spring secured in different spring screw holes c...

Страница 122: ...nding conductor is necessary for the rack installation 2 The equipment rack must provide sufficient airflow to the system to maintain proper cooling Procedure 1 Put the tighten screws2 into the washer...

Страница 123: ...sition left and right rails at the desired U position in the racks 4 Secure rails to the front and back of the racks using tighten screws1 and align pin Recommended Driver Force 7 lb in Figure 67 Secu...

Страница 124: ...er To The End Of Racks 7 Tighten the thumbscrews to secure the ears of the server to the racks Figure 70 Secure The Server Ears To Racks Note The system is not fixed to the rack or mounted to the rail...

Страница 125: ...Example SC5400 If third party chassis used indicate make and model Baseboard Information some information maybe found by accessing BIOS going through the Server Management menu System Information Bas...

Страница 126: ...mware been tried Yes No Has the latest FRU SDR been tried Yes No Has the latest HSC been tried Yes No Processor information Thermal solution Heatsink examples 1U Passive w air ducting Active w fan etc...

Страница 127: ...SCSI SATA SAS USB Tape etc Operating System Information Example RedHat Enterprise Linux Microsoft Windows Server 2003 Service pack 1 OEM CD Manufacturer Version Language version English Arabic Chinese...

Страница 128: ...rsion Has the latest RAID firmware been tried Yes No RAID driver version Has the latest RAID driver been tried Yes No RAID volumes configuration disks RAID level RAID volume use Boot device Data Volum...

Страница 129: ...please provide a brief description below Do you have systems already purchased that are not being delivered to your customers because of this issue If yes please provide a brief description below Have...

Страница 130: ...110 Intel Server System SR1680MV Service Guide...

Страница 131: ...setting the System Before going through in depth troubleshooting attempt first to perform reset your system using one of the following methods Problems following Initial System Installation Problems t...

Страница 132: ...system power cord properly connected to the system and plugged into a NEMA 5 15R outlet for 100 120V or a NEMA 6 15R outlet for 200 240V Are all integrated components from the tested components lists...

Страница 133: ...he operating system prompt does not appear see No Characters Appear on Screen Specific Problems and Corrective Actions This section provides possible solutions for these specific problems Power light...

Страница 134: ...t system Are the brightness and contrast controls on the video monitor properly adjusted Is the video monitor signal cable properly installed Does this video monitor work correctly if plugged into a d...

Страница 135: ...rd Are there any shorted wires caused by pinched cables or have power connector plugs been forced into power connector sockets the wrong way Cannot Connect to a Server Make sure the network cable is s...

Страница 136: ...e Press ID LED button or use Server Management software to turn the LED on and off System Fault Visible fault warning Control panel and board rear left corner Green or Amber Green No Fault Green blink...

Страница 137: ...on to Take 1 Control panel CMOS clear has been initiated 1 5 1 1 Processor failure Reseat or replace the failed processor 1 5 2 1 No processor is installed or the CPU 1 socket is empty Reseat or repla...

Страница 138: ...118 Intel Server System SR1680MV Service Guide...

Страница 139: ...wer supply The power cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible S...

Страница 140: ...or and heatsink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Dan...

Страница 141: ...u unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die das System gesteckt wird sollte sich in der N he des Ger tes befinden und leicht zug nglich sein SI...

Страница 142: ...e Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf o...

Страница 143: ...n zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird Le bloc d alimentation de ce produit ne contient aucune pi ce pouvant tre r par e par l utilisateur Ce...

Страница 144: ...stall sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 3 Retirez les panneaux Afin de permettre le refroidissement et l a...

Страница 145: ...es magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale cor...

Страница 146: ...mu equera antiest tica sujetada a la toma de tierra del chasis o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s de c...

Страница 147: ...trabajo normal Escoja un lugar Limpio y libre de part culas en suspensi n salvo el polvo normal Bien ventilado y alejado de fuentes de calor incluida la luz solar directa Alejado de fuentes de vibraci...

Страница 148: ...ul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sistema q...

Страница 149: ...e Il sistema progettato per funzionare in un ambiente di lavoro tipo Scegliere una postazione che sia Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente Ben...

Страница 150: ...130 Intel Server System SR1680MV Service Guide...

Страница 151: ...product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of th...

Страница 152: ...ntilated and away from sources of heat including direct sunlight and radiators Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devic...

Страница 153: ...Pole Fusing To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing The power supply in this product contains no user serviceable parts Do not open the power s...

Страница 154: ...in place Electrostatic Discharge ESD Caution ESD can damage disk drives boards and other parts We recommend that you perform all procedures at an ESD workstation If one is not available provide some E...

Страница 155: ...rte Peripherieger te Es enth lt Warnungen und Vorsichtsma nahmen zur Vermeidung von Gefahren durch Verletzung Stromschlag Feuer und Besch digungen von Ger ten Lesen Sie diese Dokument daher sorgf ltig...

Страница 156: ...en Sie einen Standort der folgenden Kriterien entspricht Sauber trocken und frei von Partikeln in der Luft au er dem normalen Raumstaub Gut bel ftet nicht in der N he von W rmequellen und keiner direk...

Страница 157: ...m f r den Zugang zu den Netzkabeln da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind Handhabung von Ger ten Beachten Sie zur Vermeidung von Verletzungen oder Besch di...

Страница 158: ...bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netz...

Страница 159: ...ben werden Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Daher sollten Sie alle Arbeiten an ein...

Страница 160: ...m nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an Verge...

Страница 161: ...duits composants annulera la liste UL et les autres approbations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S cu...

Страница 162: ...teurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectriques Dans les r gions sujettes aux orages magn tiques nous vo...

Страница 163: ...chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mettez le syst me hors tension et d branchez les cordons...

Страница 164: ...non peinte de votre serveur lorsque que vous manipulez les pi ces Manipulez toujours les cartes avec pr caution Elles peuvent tre extr mement sensibles aux ESD Ne tenez les cartes que par leurs bords...

Страница 165: ...En el caso de que haya diferencias entre la informaci n para un producto en particular contenida en este documento y la informaci n proporcionada con dicho producto o en el sitio Web la documentaci n...

Страница 166: ...a de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el ctricos En zonas propensas a tormentas el ctricas se recomienda que conecte el servidor...

Страница 167: ...de 5 V sigue activo mientras el sistema est enchufado Para desconectar el sistema debe desenchufar el cable de alimentaci n de CA de la toma de la pared Puede usar m s de un cable de alimentaci n de C...

Страница 168: ...cte todos los cables y l neas de telecomunicaci n que est n conectados al sistema Guarde todos los tornillos o elementos de fijaci n cuando retire las cubiertas de acceso Cuando termine de operar en e...

Страница 169: ...tecci n o del servidor col quela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga est tica Utilice una almohadilla de espuma conductora si dispone de ell...

Страница 170: ...ones del producto Perif ricos o dispositivos l ser Precauci n Para evitar el riesgo de la exposici n a radiaciones o de da os personales No abra la caja de ning n perif rico o dispositivo l ser Los pe...

Страница 171: ...Intel Server System SR1680MV Service Guide 151 Intel Intel Intel Web UL...

Страница 172: ...152 Intel Server System SR1680MV Service Guide ITE ITE 5V...

Страница 173: ...Intel Server System SR1680MV Service Guide 153...

Страница 174: ...154 Intel Server System SR1680MV Service Guide ESD ESD ESD ESD ESD...

Страница 175: ...Intel Server System SR1680MV Service Guide 155...

Страница 176: ...156 Intel Server System SR1680MV Service Guide...

Страница 177: ...end system product may require additional EMC compliance testing For more information please contact your local Intel representative This is an FCC Class A device Integration of it into a Class B syst...

Страница 178: ...e 73 23 EEE Europe IRAM Certification Argentina Product EMC Compliance Class A Compliance FCC ICES 003 Emissions USA Canada Verification CISPR 22 Emissions International EN55022 Emissions Europe EN550...

Страница 179: ...brominated Biphenyls Diphenyl Ethers PBB PBDE Quantity limit of 0 01 by mass 100 PPM for Cadmium California Code of Regulations Title 22 Division 4 5 Chapter 33 Best Management Practices for Perchlora...

Страница 180: ...tory and safety markings In the event there is no room for a marking s on the chassis the information is provided here in this guide Table 50 Product Regulatory Compliance Markings Regulatory Complian...

Страница 181: ...System SR1680MV Service Guide 161 KCC Mark Korea CPU SR1680 A GOST Mark Russia MO04 BSMI Mark Taiwan R33025 UL Mark USA Canada Table 50 Product Regulatory Compliance Markings Regulatory Compliance Cou...

Страница 182: ...terference that may cause undesired operation Country of Origin Mark Country of Origin Mark Made in China Nordic Ground Marking Nordic Ground Marking Line1 WARNING Swedish on line2 Apparaten skall ans...

Страница 183: ...connect 2 two power supply cords before servicing Simplified Chinese 2 Traditional Chinese 2 German Dieses Ger te hat mehr als ein Stromkabel Um eine Gefahr des elektrischen Schlages zu verringern tre...

Страница 184: ...orate insert CA Perchlorate Material Special handling may apply See www dtsc ca gov hazardouswaste perchlorate This notice is required by California Code of Regulations Title 22 Division 4 5 Chapter 3...

Страница 185: ...er will be used If AC power supplies are installed Mains AC power disconnection The AC power cord s is considered the mains disconnect for the server and must be readily accessible when installed If t...

Страница 186: ...ear of the server The safety ground conductor should be connected to the chassis stud with a Listed closed two hole crimp terminal having 5 8 inch pitch The nuts on the chassis earth ground studs shou...

Страница 187: ...e Listed and rated 125 of overall current rating of the server Connector server end The connectors that plug into the AC receptacle on the server must be an approved IEC International Electrotechnical...

Страница 188: ...not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encour...

Страница 189: ...t standard entitled Digital Apparatus ICES 003 of the Canadian Department of Communications CE Declaration of Conformity Europe This product has been tested in accordance to and complies with the Low...

Страница 190: ...pient Intel Corporation 4 Date of Manufacturer Refer to date code on product 5 Manufacturer Nation Intel Corporation Refer to country of origin marked on product Regulated Specified Components To main...

Страница 191: ...Add in boards containing external power connectors and or lithium batteries must be UL recognized or UL listed Any add in board containing modem telecommunication circuitry must be UL listed In addit...

Страница 192: ...172 Intel Server System SR1680MV Service Guide...

Страница 193: ...Server System SR1680MV Service Guide 173 Appendix F Warranty To obtain warranty service for this Product visit the following Intel website http support intel com support motherboards server sb CS 0108...

Страница 194: ...174 Intel Server System SR1680MV Service Guide...

Страница 195: ...r and chassis accessory parts list for ordering upgrades or spare parts A searchable knowledgebase to search for product information throughout the support site 2 If you are still unable to obtain a s...

Страница 196: ...176 Intel Server System SR1680MV Service Guide...

Отзывы: