116
Intel
®
Server System SR1680MV Service Guide
LED Information
The Intel
®
Server SR6880MV includes LEDs that can aid in troubleshooting your system.
A table of these LEDs with a description of their use is listed below.
BIOS POST Beep Codes
The table below lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users of error conditions. Please note that not all
error conditions are supported by BIOS beep codes.
Table 47. LED Information
LED Name
Function
Location
LED Color
Notes
Power
Indicates system power
is on or off
Front control
panel
Green
Off = Power is off or in sleep
state S5
On = Power is on or in sleep
stats S0
ID
Aid in server
identification from the
back panel
Front control
panel and
board rear left
corner
Blue
Press ID LED button or use
Server Management software
to turn the LED on and off.
System Fault
Visible fault warning
Control panel
and board rear
left corner
Green or
Amber
Green = No Fault
Green blinking = degraded
condition
Amber blinking = non-critical
error
Amber = critical or non-
recoverable error
Drive Activity
Table 48. POST Error Beep Codes
Number of Beeps
Reason for Beeps and Action to Take
1, 2, or 3
Memory error. Reseat the memory or replace the DIMMs with known good
modules.
4 - 7 or 9 - 11
Fatal error indicating a possible serious system problem. Remove all add-
in cards and re-start the system. If the error still occurs, contact your
system manufacturer. If the beep codes are not generated after the add-in
cards are removed, insert the cards one at a time, booting the system
between each card addition, until the beeps again occur to reveal the
malfunctioning card.
8
Replace or reseat the system video add-in card. If on-board video is being
used, the server board may be faulty.
Содержание SR1680MV - Server System - 0 MB RAM
Страница 6: ...vi Intel Server System SR1680MV Service Guide...
Страница 10: ...x Intel Server System SR1680MV Service Guide...
Страница 16: ...xvi Intel Server System SR1680MV Service Guide...
Страница 28: ...8 Intel Server System SR1680MV Service Guide...
Страница 62: ...42 Intel Server System SR1680MV Service Guide...
Страница 65: ...Intel Server System SR1680MV Service Guide 45 Figure 53 Connecting the System Fan Cables...
Страница 66: ...46 Intel Server System SR1680MV Service Guide...
Страница 78: ...58 Intel Server System SR1680MV Service Guide...
Страница 118: ...98 Intel Server System SR1680MV Service Guide...
Страница 120: ...100 Intel Server System SR1680MV Service Guide...
Страница 130: ...110 Intel Server System SR1680MV Service Guide...
Страница 138: ...118 Intel Server System SR1680MV Service Guide...
Страница 150: ...130 Intel Server System SR1680MV Service Guide...
Страница 171: ...Intel Server System SR1680MV Service Guide 151 Intel Intel Intel Web UL...
Страница 172: ...152 Intel Server System SR1680MV Service Guide ITE ITE 5V...
Страница 173: ...Intel Server System SR1680MV Service Guide 153...
Страница 174: ...154 Intel Server System SR1680MV Service Guide ESD ESD ESD ESD ESD...
Страница 175: ...Intel Server System SR1680MV Service Guide 155...
Страница 176: ...156 Intel Server System SR1680MV Service Guide...
Страница 192: ...172 Intel Server System SR1680MV Service Guide...
Страница 194: ...174 Intel Server System SR1680MV Service Guide...
Страница 196: ...176 Intel Server System SR1680MV Service Guide...