Intel® Server System S9200WK Product Family Setup and Service Guide
26
1.
Remove the compute module to be serviced from the server chassis and place it on to an anti-static
work surface (see Section 4.2.1)
2.
Remove the selected riser assembly from the compute module (see Section 0)
3.
Carefully remove the add-in card from the PCIe slot (see Letter A).
4.
Carefully install the metal filler plate over the opening on the metal frame of the riser assembly (see
Letter B).
5.
Re-install the riser card assembly into the compute module (see Section 4.3)
3.4
Ethernet Management Port Module (EMP Module)
–
iPC AXXFCEMP
Your system may or may not come preconfigured with an Ethernet Management Port Module. This section
provides instruction for the installation and removal of this accessory option. The EMP module is hot-swap
capable. It can be installed or removed without powering down the system or any of its compute modules.
3.4.1
Installing the EMP Module
Figure 19. Removing the EMP Bay Filler Blank
1.
If present, remove the EMP Bay Filler blank from the back of the server chassis by pulling it out from
the chassis as shown in Figure
Figure 20. Installing the EMP module/blank
2.
Install the EMP module, by sliding it into the open EMP bay until it locks into place (see Letter A).
A