Intel® Server System S9200WK Product Family Setup and Service Guide
33
4.2
Compute Module Replacement
All installed compute modules within an Intel® Server System S9200WK are independent from each other.
Servicing a compute module does not require having to power down the full server system. Only the
compute module to be serviced must be powered down before being removed from the server chassis.
Replacement of compute modules (spare or warranty replacement) will include the following:
•
Compute Module Tray
•
Server Board with processors
•
Riser Card Assemblies
•
Liquid Cooling Loop (liquid cooled compute modules only)
•
Processor Heat Sinks (air cooled compute modules only)
•
Air Duct (2U air cooled compute modules only)
When returning a compute module for warranty replacement, the following components must be removed
before shipment (if present) :
•
Memory (DIMMs)
•
DIMM retention clips
•
PCIe* add-in cards
•
Add-on storage devices (M.2 SSD, U.2 SSD)
•
Intel® RMM4 Lite key
•
Intel® VROC upgrade key
Note
: Processors are soldered to the server board, they are not removable. Processors are included when
ordering a spare or warranty replacement compute module. Refer to the
Intel® Server System S9200WK
Product Family Configuration Guide
for available spares.
The following procedures are identical for both 1U and 2U compute modules.
4.2.1
Compute Module Removal
1.
Power down the compute module using the Power Button
located on the front panel of the
compute module to be serviced.
Figure 26. Removing a compute module