Intel® Server System S9200WK Product Family Setup and Service Guide
82
LED State
System State
BIOS Status Description
Solid amber
Critical/non-recoverable
–
system is halted. Fatal alarm
–
system has failed or shut
down.
CPU CATERR signal asserted.
MSID mismatch detected (CATERR also asserts for this case).
CPU 1 is missing.
CPU Thermal Trip.
No power good
–
power fault.
DIMM failure when there is only 1 DIMM present and hence no good memory
present.
Runtime memory uncorrectable error in non-redundant mode.
DIMM Thermal Trip or equivalent.
SSB Thermal Trip or equivalent.
CPU ERR2 signal asserted.
BMC/Video memory test failed. (Chassis ID shows blue/solid-on for this
condition.)
Both uBoot BMC firmware images are bad. (Chassis ID shows blue/solid-on for
this condition.)
240 VA fault.
Fatal Error in processor initialization:
o
Processor family not identical
o
Processor model not identical
o
Processor core/thread counts not identical
o
Processor cache size not identical
o
Unable to synchronize processor frequency
o
Unable to synchronize QPI link frequency
Uncorrectable memory error in a non-redundant mode.