Intel® Server System S9200WK Product Family Setup and Service Guide
36
4.3.2
Riser Assembly Installation
Figure 29. Installing a riser assembly
1.
Align the riser card edge connector to the riser slot on the server board (see Letter A).
2.
Carefully push down on the riser assembly until the riser card is securely seated into the riser slot.
3.
Ensure the three screw holes of the riser assembly are aligned and flush with the mounting holes of
the compute module.
4.
With three screws, secure the riser assembly to the compute module using 8 lbs. of torque on each
(see Letter B).
4.4
Drive Carrier Extraction, Assembly, and Installation
The 2U compute modules of the Intel® Server System S9200WK product family have support for up to two
hot-swap
2.5” form factor U.2 Solid State Drives
(SSDs). Each drive installed to a tool-less drive carrier. This
section provides instructions for drive extraction from the chassis, drive assembly, and drive installation into
the chassis.
Required Tools and Supplies:
•
Anti-static wrist strap and conductive foam pad (recommended)